Automated drug delivery system to control systemic arterial pressure, cardiac output, and left heart filling pressure in acute decompensated heart failure
Authors:
- Kazunori UemuraKUKazunori Uemura
- Makoto YoshizawaMYMakoto Yoshizawa
- Kenji SunagawaKSKenji Sunagawa
Open Access
- 1 April 2006
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 100 (4) , 1278-1286
Abstract
Pharmacological support with inotropes and vasodilators to control decompensated hemodynamics requires strict monitoring of patient condition and frequent adjustments of drug infusion rates, which is difficult and time-consuming, especially in hemodynamically unstable patients. To overcome this difficulty, we have developed a novel automated drug delivery system for simultaneous control of systemic arterial pressure (AP), cardiac output (CO), and left atrial pressure (Pla). Previous systems attempted to directly control AP and CO by estimating their responses to drug infusions. This approach is inapplicable because of the difficulties to estimate simultaneous AP, CO, and Pla responses to the infusion of multiple drugs. The circulatory equilibrium framework developed previously (Uemura K, Sugimachi M, Kawada T, Kamiya A, Jin Y, Kashihara K, and Sunagawa K. Am J Physiol Heart Circ Physiol 286: H2376–H2385, 2004) indicates that AP, CO, and Pla are determined by an equilibrium of the pumping ability of the left heart (SL), stressed blood volume (V), and systemic arterial resistance (R). Our system directly controls SLwith dobutamine, V with dextran/furosemide, and R with nitroprusside, thereby controlling the three variables. We evaluated the efficacy of our system in 12 anesthetized dogs with acute decompensated heart failure. Once activated, the system restored SL, V, and R within 30 min, resulting in the restoration of normal AP, CO, and Pla. Steady-state deviations from target values were small for AP [4.4 mmHg (SD 2.6)], CO [5.4 ml·min−1·kg−1(SD 2.4)] and Pla [0.8 mmHg (SD 0.6)]. In conclusion, by directly controlling the mechanical determinants of circulation, our system has enabled simultaneous control of AP, CO, and Pla with good accuracy and stability.Keywords
This publication has 25 references indexed in Scilit:
- Prediction of circulatory equilibrium in response to changes in stressed blood volumeAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- ACC/AHA Guidelines for the Management of Patients With ST-Elevation Myocardial Infarction—Executive SummaryJACC, 2004
- A novel framework of circulatory equilibriumAmerican Journal of Physiology-Heart and Circulatory Physiology, 2004
- Estimation of pulmonary artery occlusion pressure by an artificial neural networkCritical Care Medicine, 2003
- Multicenter trial of automated nitroprusside infusion for postoperative hypertensionThe Annals of Thoracic Surgery, 1992
- Effects of Nitroglycerin and Nitroprusside on Vascular Capacitance of Anesthetized Ganglion-Blocked DogsJournal of Cardiovascular Pharmacology, 1991
- Automated control of postoperative hypertension: A prospective, randomized multicenter studyThe Annals of Thoracic Surgery, 1989
- The physiologic reserve in oxygen carrying capacity: studies in experimental hemodilutionCanadian Journal of Physiology and Pharmacology, 1986
- β-Adrenergic Receptors, Adenylate Cyclase Activity, and Cardiac Dysfunction in the Diabetic RatJournal of Cardiovascular Pharmacology, 1985