Kazunori Uemura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Kazunori Uemura has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Masaru Sugimachi
Department of Cardiovascular Dynamics, National Cerebral and Cardiovascular Center, Osaka 565-8565, Japan; Department of Artificial Organ Medicine, Faculty of Medicine, Osaka University Graduate School of Medicine, Osaka 565-0871, Japan
12 shared publicationsKenji Sunagawa
8 shared publicationsToru Kawada
8 shared publicationsAtsunori Kamiya
5 shared publications- Kenji Sunagawa
Department of Cardiovascular Medicine, Kyushu University Graduate School of Medical Sciences
3 shared publications - Koji Kashihara
Institute of Technology and Science, The University of Tokushima, 2-1 Minamijyousanjima, 770-8506, Japan
3 shared publications
Latest Publications
- 1 October 2017
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 23 (10) , S14
The Framework of Circulatory Equilibrium Can Predict the Quantitative Impact of Interatrial Shunt for Left Heart Failure on Hemodynamics
- 1 October 2017
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 23 (10) , S14
The Framework of Circulatory Equilibrium Can Predict the Quantitative Impact of Interatrial Shunt for Left Heart Failure on Hemodynamics
- 13 September 2017
- Published by Elsevier in International Journal of Cardiology
- Vol. 249, 396-401
Wave reflection correlates with pulmonary vascular wall thickening in rats with pulmonary arterial hypertension
- 13 September 2017
- Published by Elsevier in International Journal of Cardiology
- Vol. 249, 396-401
Wave reflection correlates with pulmonary vascular wall thickening in rats with pulmonary arterial hypertension
- 1 May 2011
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 24 (5) , 582-591
Peak Systolic Mitral Annulus Velocity Reflects the Status of Ventricular-Arterial Coupling—Theoretical and Experimental Analyses
- 1 May 2011
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 24 (5) , 582-591
Peak Systolic Mitral Annulus Velocity Reflects the Status of Ventricular-Arterial Coupling—Theoretical and Experimental Analyses
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 5222-5225
Automated drug delivery system for the management of hemodynamics and cardiac energetic in acute heart failure
We have developed a novel automated drug delivery system for simultaneous control of systemic arterial pressure (AP), cardiac output (CO), and left atrial pressure (PLA) in acute heart failure. The circulatory equilibrium framework we established previously discloses that AP, CO, and PLA are determined by equilibrium of the mechanical properties of the circulation, i.e. pumping ability of the left heart, stressed blood volume and systemic arterial resistance. Our system directly controls the three mechanical properties with cardiovascular drugs including inotropes and vasodilators, thereby controlling AP, CO, and PLA. Furthermore, by precisely controlling bradycardia and LV inotropy, our system enables to improve cardiac energetic efficiency while preserving AP, CO, and PLA within acceptable ranges. In conclusion, by directly controlling the mechanical properties of the heart and vessel, our automated system realizes comprehensive management of hemodynamics in acute heart failure.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 5222-5225
Automated drug delivery system for the management of hemodynamics and cardiac energetic in acute heart failure
We have developed a novel automated drug delivery system for simultaneous control of systemic arterial pressure (AP), cardiac output (CO), and left atrial pressure (PLA) in acute heart failure. The circulatory equilibrium framework we established previously discloses that AP, CO, and PLA are determined by equilibrium of the mechanical properties of the circulation, i.e. pumping ability of the left heart, stressed blood volume and systemic arterial resistance. Our system directly controls the three mechanical properties with cardiovascular drugs including inotropes and vasodilators, thereby controlling AP, CO, and PLA. Furthermore, by precisely controlling bradycardia and LV inotropy, our system enables to improve cardiac energetic efficiency while preserving AP, CO, and PLA within acceptable ranges. In conclusion, by directly controlling the mechanical properties of the heart and vessel, our automated system realizes comprehensive management of hemodynamics in acute heart failure.
- 1 August 2010
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 16 (8) , 689-699
Early Short-Term Vagal Nerve Stimulation Attenuates Cardiac Remodeling After Reperfused Myocardial Infarction
- 1 August 2010
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 16 (8) , 689-699
Early Short-Term Vagal Nerve Stimulation Attenuates Cardiac Remodeling After Reperfused Myocardial Infarction
- 12 November 2008
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 37 (1) , 82-93
Computationally Managed Bradycardia Improved Cardiac Energetics While Restoring Normal Hemodynamics in Heart Failure
In acute heart failure, systemic arterial pressure (AP), cardiac output (CO), and left atrial pressure (P LA) have to be controlled within acceptable ranges. Under this condition, cardiac energetic efficiency should also be improved. Theoretically, if heart rate (HR) is reduced while AP, CO, and P LA are maintained by preserving the functional slope of left ventricular (LV) Starling’s curve (S L) with precisely increased LV end-systolic elastance (E es), it is possible to improve cardiac energetic efficiency and reduce LV oxygen consumption per minute (MVO 2). We investigated whether this hemodynamics can be accomplished in acute heart failure using an automated hemodynamic regulator that we developed previously. In seven anesthetized dogs with acute heart failure (CO < 70 mL min−1 kg−1, P LA > 15 mmHg), the regulator simultaneously controlled S L with dobutamine, systemic vascular resistance with nitroprusside and stressed blood volume with dextran or furosemide, thereby controlling AP, CO, and P LA. Normal hemodynamics were restored and maintained (CO; 88 ± 3 mL min−1 kg−1, P LA; 10.9 ± 0.4 mmHg), even when zatebradine significantly reduced HR (−27 ± 3%). Following HR reduction, E es increased (+34 ± 14%), LV mechanical efficiency (stroke work/oxygen consumption) increased (+22 ± 6%), and MVO 2 decreased (−17 ± 4%) significantly. In conclusion, in a canine acute heart failure model, computationally managed bradycardia improved cardiac energetic efficiency while restoring normal hemodynamic conditions.
- 12 November 2008
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 37 (1) , 82-93
Computationally Managed Bradycardia Improved Cardiac Energetics While Restoring Normal Hemodynamics in Heart Failure
In acute heart failure, systemic arterial pressure (AP), cardiac output (CO), and left atrial pressure (P LA) have to be controlled within acceptable ranges. Under this condition, cardiac energetic efficiency should also be improved. Theoretically, if heart rate (HR) is reduced while AP, CO, and P LA are maintained by preserving the functional slope of left ventricular (LV) Starling’s curve (S L) with precisely increased LV end-systolic elastance (E es), it is possible to improve cardiac energetic efficiency and reduce LV oxygen consumption per minute (MVO 2). We investigated whether this hemodynamics can be accomplished in acute heart failure using an automated hemodynamic regulator that we developed previously. In seven anesthetized dogs with acute heart failure (CO < 70 mL min−1 kg−1, P LA > 15 mmHg), the regulator simultaneously controlled S L with dobutamine, systemic vascular resistance with nitroprusside and stressed blood volume with dextran or furosemide, thereby controlling AP, CO, and P LA. Normal hemodynamics were restored and maintained (CO; 88 ± 3 mL min−1 kg−1, P LA; 10.9 ± 0.4 mmHg), even when zatebradine significantly reduced HR (−27 ± 3%). Following HR reduction, E es increased (+34 ± 14%), LV mechanical efficiency (stroke work/oxygen consumption) increased (+22 ± 6%), and MVO 2 decreased (−17 ± 4%) significantly. In conclusion, in a canine acute heart failure model, computationally managed bradycardia improved cardiac energetic efficiency while restoring normal hemodynamic conditions.
- 1 October 2007
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 293 (4) , H2254-H2261
Efferent vagal nerve stimulation induces tissue inhibitor of metalloproteinase-1 in myocardial ischemia-reperfusion injury in rabbit
Vagal nerve stimulation has been suggested to ameliorate left ventricular (LV) remodeling in heart failure. However, it is not known whether and to what degree vagal nerve stimulation affects matrix metalloproteinase (MMP) and tissue inhibitor of MMP (TIMP) in myocardium, which are known to play crucial roles in LV remodeling. We therefore investigated the effects of electrical stimulation of efferent vagal nerve on myocardial expression and activation of MMPs and TIMPs in a rabbit model of myocardial ischemia-reperfusion (I/R) injury. Anesthetized rabbits were subjected to 60 min of left coronary artery occlusion and 180 min of reperfusion with (I/R-VS, n = 8) or without vagal nerve stimulation (I/R, n = 7). Rabbits not subjected to coronary occlusion with (VS, n = 7) or without vagal stimulation (sham, n = 7) were used as controls. Total MMP-9 protein increased significantly after left coronary artery occlusion in I/R-VS and I/R to a similar degree compared with VS and sham values. Endogenous active MMP-9 protein level was significantly lower in I/R-VS compared with I/R. TIMP-1 mRNA expression was significantly increased in I/R-VS compared with the I/R, VS, and sham groups. TIMP-1 protein was significantly increased in I/R-VS and VS compared with the I/R and sham groups. Cardiac microdialysis technique demonstrated that topical perfusion of acetylcholine increased dialysate TIMP-1 protein level, which was suppressed by coperfusion of atropine. Immunohistochemistry demonstrated a strong expression of TIMP-1 protein in cardiomyocytes around the dialysis probe used to perfuse acetylcholine. In conclusion, in a rabbit model of myocardial I/R injury, vagal nerve stimulation induced TIMP-1 expression in cardiomyocytes and reduced active MMP-9.
- 1 October 2007
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 293 (4) , H2254-H2261
Efferent vagal nerve stimulation induces tissue inhibitor of metalloproteinase-1 in myocardial ischemia-reperfusion injury in rabbit
Vagal nerve stimulation has been suggested to ameliorate left ventricular (LV) remodeling in heart failure. However, it is not known whether and to what degree vagal nerve stimulation affects matrix metalloproteinase (MMP) and tissue inhibitor of MMP (TIMP) in myocardium, which are known to play crucial roles in LV remodeling. We therefore investigated the effects of electrical stimulation of efferent vagal nerve on myocardial expression and activation of MMPs and TIMPs in a rabbit model of myocardial ischemia-reperfusion (I/R) injury. Anesthetized rabbits were subjected to 60 min of left coronary artery occlusion and 180 min of reperfusion with (I/R-VS, n = 8) or without vagal nerve stimulation (I/R, n = 7). Rabbits not subjected to coronary occlusion with (VS, n = 7) or without vagal stimulation (sham, n = 7) were used as controls. Total MMP-9 protein increased significantly after left coronary artery occlusion in I/R-VS and I/R to a similar degree compared with VS and sham values. Endogenous active MMP-9 protein level was significantly lower in I/R-VS compared with I/R. TIMP-1 mRNA expression was significantly increased in I/R-VS compared with the I/R, VS, and sham groups. TIMP-1 protein was significantly increased in I/R-VS and VS compared with the I/R and sham groups. Cardiac microdialysis technique demonstrated that topical perfusion of acetylcholine increased dialysate TIMP-1 protein level, which was suppressed by coperfusion of atropine. Immunohistochemistry demonstrated a strong expression of TIMP-1 protein in cardiomyocytes around the dialysis probe used to perfuse acetylcholine. In conclusion, in a rabbit model of myocardial I/R injury, vagal nerve stimulation induced TIMP-1 expression in cardiomyocytes and reduced active MMP-9.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 198-201
Comprehensive Physiological Cardiovascular Model Enables Automatic Correction of Hemodynamics in Patients with Acute Life-Threatening Heart Failure
Saving life of patients with acute life-threatening heart failure is a major challenge. One has to correct several fatal hemodynamic abnormalities at the same time within a limited time frame. The formulation of such complicated treatments enables the development of a system that can be used to save automatically lives of patients with acute heart failure, an autopilot system. To accomplish this, we established a comprehensive physiological cardiovascular model, on which we based the design of the autopilot system. By translating hemodynamics into cardiovascular parameters (pumping ability, vascular resistance, blood volume), and by controlling each of these with individual drugs, we were able to correct blood pressure, cardiac output, and left atrial pressure to the target values rapidly (5.2plusmn6.6,6.8plusmn4.6, and 11.7plusmn9.8 minutes), stably, and simultaneously
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 198-201
Comprehensive Physiological Cardiovascular Model Enables Automatic Correction of Hemodynamics in Patients with Acute Life-Threatening Heart Failure
Saving life of patients with acute life-threatening heart failure is a major challenge. One has to correct several fatal hemodynamic abnormalities at the same time within a limited time frame. The formulation of such complicated treatments enables the development of a system that can be used to save automatically lives of patients with acute heart failure, an autopilot system. To accomplish this, we established a comprehensive physiological cardiovascular model, on which we based the design of the autopilot system. By translating hemodynamics into cardiovascular parameters (pumping ability, vascular resistance, blood volume), and by controlling each of these with individual drugs, we were able to correct blood pressure, cardiac output, and left atrial pressure to the target values rapidly (5.2plusmn6.6,6.8plusmn4.6, and 11.7plusmn9.8 minutes), stably, and simultaneously
- Open Access
- 1 April 2006
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 100 (4) , 1278-1286
Automated drug delivery system to control systemic arterial pressure, cardiac output, and left heart filling pressure in acute decompensated heart failure
Pharmacological support with inotropes and vasodilators to control decompensated hemodynamics requires strict monitoring of patient condition and frequent adjustments of drug infusion rates, which is difficult and time-consuming, especially in hemodynamically unstable patients. To overcome this difficulty, we have developed a novel automated drug delivery system for simultaneous control of systemic arterial pressure (AP), cardiac output (CO), and left atrial pressure (Pla). Previous systems attempted to directly control AP and CO by estimating their responses to drug infusions. This approach is inapplicable because of the difficulties to estimate simultaneous AP, CO, and Pla responses to the infusion of multiple drugs. The circulatory equilibrium framework developed previously (Uemura K, Sugimachi M, Kawada T, Kamiya A, Jin Y, Kashihara K, and Sunagawa K. Am J Physiol Heart Circ Physiol 286: H2376–H2385, 2004) indicates that AP, CO, and Pla are determined by an equilibrium of the pumping ability of the left heart (SL), stressed blood volume (V), and systemic arterial resistance (R). Our system directly controls SLwith dobutamine, V with dextran/furosemide, and R with nitroprusside, thereby controlling the three variables. We evaluated the efficacy of our system in 12 anesthetized dogs with acute decompensated heart failure. Once activated, the system restored SL, V, and R within 30 min, resulting in the restoration of normal AP, CO, and Pla. Steady-state deviations from target values were small for AP [4.4 mmHg (SD 2.6)], CO [5.4 ml·min−1·kg−1(SD 2.4)] and Pla [0.8 mmHg (SD 0.6)]. In conclusion, by directly controlling the mechanical determinants of circulation, our system has enabled simultaneous control of AP, CO, and Pla with good accuracy and stability.
- 1 April 2006
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 100 (4) , 1278-1286
Open AccessAutomated drug delivery system to control systemic arterial pressure, cardiac output, and left heart filling pressure in acute decompensated heart failure
Pharmacological support with inotropes and vasodilators to control decompensated hemodynamics requires strict monitoring of patient condition and frequent adjustments of drug infusion rates, which is difficult and time-consuming, especially in hemodynamically unstable patients. To overcome this difficulty, we have developed a novel automated drug delivery system for simultaneous control of systemic arterial pressure (AP), cardiac output (CO), and left atrial pressure (Pla). Previous systems attempted to directly control AP and CO by estimating their responses to drug infusions. This approach is inapplicable because of the difficulties to estimate simultaneous AP, CO, and Pla responses to the infusion of multiple drugs. The circulatory equilibrium framework developed previously (Uemura K, Sugimachi M, Kawada T, Kamiya A, Jin Y, Kashihara K, and Sunagawa K. Am J Physiol Heart Circ Physiol 286: H2376–H2385, 2004) indicates that AP, CO, and Pla are determined by an equilibrium of the pumping ability of the left heart (SL), stressed blood volume (V), and systemic arterial resistance (R). Our system directly controls SLwith dobutamine, V with dextran/furosemide, and R with nitroprusside, thereby controlling the three variables. We evaluated the efficacy of our system in 12 anesthetized dogs with acute decompensated heart failure. Once activated, the system restored SL, V, and R within 30 min, resulting in the restoration of normal AP, CO, and Pla. Steady-state deviations from target values were small for AP [4.4 mmHg (SD 2.6)], CO [5.4 ml·min−1·kg−1(SD 2.4)] and Pla [0.8 mmHg (SD 0.6)]. In conclusion, by directly controlling the mechanical determinants of circulation, our system has enabled simultaneous control of AP, CO, and Pla with good accuracy and stability.
- Open Access
- 1 July 2005
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 289 (1) , H301-H307
Prediction of circulatory equilibrium in response to changes in stressed blood volume
Accurate prediction of cardiac output (CO), left atrial pressure (PLA), and right atrial pressure (PRA) is a prerequisite for management of patients with compromised hemodynamics. In our previous study (Uemura et al. Am J Physiol Heart Circ Physiol 286: H2376–H2385, 2004), we demonstrated a circulatory equilibrium framework, which permits the prediction of CO, PLA, and PRA once the venous return surface and integrated CO curve are known. Inasmuch as we also showed that the surface can be estimated from single-point CO, PLA, and PRA measurements, we hypothesized that a similar single-point estimation of the CO curve would enable us to predict hemodynamics. In seven dogs, we measured the PLA-CO and PRA-CO relations and derived a standardized CO curve using the logarithmic function CO = SL[ln(PLA − 2.03) + 0.80] for the left heart and CO = SR[ln(PRA − 2.13) + 1.90] for the right heart, where SL and SR represent the preload sensitivity of CO, i.e., pumping ability, of the left and right heart, respectively. To estimate the integrated CO curve in each animal, we calculated SL and SR from single-point CO, PLA, and PRA measurements. Estimated and measured CO agreed reasonably well. In another eight dogs, we altered stressed blood volume (−8 to +8 ml/kg of reference volume) under normal and heart failure conditions and predicted the hemodynamics by intersecting the surface and the CO curve thus estimated. We could predict CO [ y = 0.93 x + 6.5, r 2 = 0.96, standard error of estimate (SEE) = 7.5 ml·min−1·kg−1], PLA ( y = 0.90 x + 0.5, r 2 = 0.93, SEE = 1.4 mmHg), and PRA ( y = 0.87 x + 0.4, r 2 = 0.91, SEE = 0.4 mmHg) reasonably well. In conclusion, single-point estimation of the integrated CO curve enables accurate prediction of hemodynamics in response to extensive changes in stressed blood volume.
- 1 July 2005
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 289 (1) , H301-H307
Open AccessPrediction of circulatory equilibrium in response to changes in stressed blood volume
Accurate prediction of cardiac output (CO), left atrial pressure (PLA), and right atrial pressure (PRA) is a prerequisite for management of patients with compromised hemodynamics. In our previous study (Uemura et al. Am J Physiol Heart Circ Physiol 286: H2376–H2385, 2004), we demonstrated a circulatory equilibrium framework, which permits the prediction of CO, PLA, and PRA once the venous return surface and integrated CO curve are known. Inasmuch as we also showed that the surface can be estimated from single-point CO, PLA, and PRA measurements, we hypothesized that a similar single-point estimation of the CO curve would enable us to predict hemodynamics. In seven dogs, we measured the PLA-CO and PRA-CO relations and derived a standardized CO curve using the logarithmic function CO = SL[ln(PLA − 2.03) + 0.80] for the left heart and CO = SR[ln(PRA − 2.13) + 1.90] for the right heart, where SL and SR represent the preload sensitivity of CO, i.e., pumping ability, of the left and right heart, respectively. To estimate the integrated CO curve in each animal, we calculated SL and SR from single-point CO, PLA, and PRA measurements. Estimated and measured CO agreed reasonably well. In another eight dogs, we altered stressed blood volume (−8 to +8 ml/kg of reference volume) under normal and heart failure conditions and predicted the hemodynamics by intersecting the surface and the CO curve thus estimated. We could predict CO [ y = 0.93 x + 6.5, r 2 = 0.96, standard error of estimate (SEE) = 7.5 ml·min−1·kg−1], PLA ( y = 0.90 x + 0.5, r 2 = 0.93, SEE = 1.4 mmHg), and PRA ( y = 0.87 x + 0.4, r 2 = 0.91, SEE = 0.4 mmHg) reasonably well. In conclusion, single-point estimation of the integrated CO curve enables accurate prediction of hemodynamics in response to extensive changes in stressed blood volume.