Novel in Vitro Model for Assessing Susceptibility of Synthetic Hernia Repair Meshes to Staphylococcus aureus Infection Using Green Fluorescent Protein-Labeled Bacteria and Modern Imaging Techniques
- 1 October 2010
- journal article
- research article
- Published by SAGE Publications in Surgical Infections
- Vol. 11 (5) , 449-454
Abstract
Background: Mesh infection complicating hernia repair is a major cause of patient morbidity and results in substantial healthcare expenditures. The various constructs of prosthetic mesh may alter the ability of bacteria to attach and form a biofilm. Few data exist evaluating biofilm formation. Using the Maestro in-Vivo Imaging System (CRi, Inc., Woburn, MA) to detect green fluorescent protein (GFP)-expressing Staphylococcus aureus, we studied the ability of synthetic mesh to withstand bacterial biofilm formation in an in vitro model. Methods: We included four meshes: Polypropylene (PP), polypropylene/expanded PTFE (PX), compressed PTFE (cPTFE), and polyester/polyethylene glycol and collagen hydrogel (PE). Five samples of each mesh were exposed to GFP-expressing S. aureus for 18 h at 37°C. Next, green fluorescence was measured using the Maestro Imaging System, with the results expressed in relative fluorescence units (RFU), subtracting the fluorescence of uninfected mesh (control). Each mesh subsequently underwent sonication and quantitative culture of the released bacteria, with the results expressed in colony-forming units (CFU). Analysis of variance was performed to compare the mean values for the different meshes. Results: There was a statistically significant difference in bacterial fluorescence for the four meshes: PE (49.9 ± 25.5 [standard deviation] RFU), PX (30.8 ± 9.4 RFU), cPTFE (10.1 ± 4.0 RFU), and PP (5.8 ± 7.5 RFU)(p = 0.001). Bacterial counts also were significantly different: PE (2.2 × 108 CFU), PX (8.6 × 107 CFU), cPTFE (3.7 × 107 CFU), and PP (9.1 × 107 CFU)(p < 0.001). Conclusion: Using novel imaging technology, this study documented significantly different amounts of S. aureus biofilm formation and proliferation on different mesh constructs, with good agreement between imaging and culture results. A multifilament woven mesh (PE) had the highest degree of biofilm formation. These findings are being evaluated in a clinical infection model.Keywords
This publication has 29 references indexed in Scilit:
- Infection Potentiation Study of Synthetic and Naturally Derived Surgical Mesh in MiceSurgical Infections, 2007
- The phenomenon of infection with abdominal wall reconstructionBiomaterials, 2007
- S. epidermidis biofilm formation: Effects of biomaterial surface chemistry and serum proteinsJournal of Biomedical Materials Research Part A, 2007
- In vitro infectability of prosthetic mesh by methicillin-resistant Staphylococcus aureusHernia, 2006
- Laparoscopic incisional and ventral hernioplasty: lessons learned from 200 patientsHernia, 2003
- Thoracoscopic Sympathectomy for Palmaris HyperhidrosisSouthern Medical Journal, 2003
- Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat modelJournal of Biomedical Materials Research, 2002
- Antibiotic prophylaxis in incisional hernia repair using a prosthesisHernia, 2001
- Penetration of Staphylococcus aureus into sutured woundsJournal of Orthopaedic Research, 1984
- Adhesion of Coagulase-negative Staphylococci to BiomaterialsMicrobiology, 1983