In Vivo Kinematics of Two Types of Ball-and-Socket Cervical Disc Replacements in the Sagittal Plane
Authors:
- Marc-Antoine RousseauMRMarc-Antoine Rousseau
- Philippe CottinPCPhilippe Cottin
- Stéphane LevanteSLStéphane Levante
- Nogier AlexisNANogier Alexis
- Jean-Yves LazennecJLJean-Yves Lazennec
- Wafa SkalliWSWafa Skalli
- 1 January 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 33 (1) , E6-E9
Abstract
A computer-assisted analysis of dynamic lateral radiographs of the cervical spine in flexion/extension after total disc replacement. To analyze the in vivo kinematics of 2 types of ball-and-socket cervical disc arthroplasties. Clinical outcomes and range of motion (ROM) after cervical disc replacement have been documented in few studies. To our knowledge, no article reports the biomechanical behavior of any type of ball-and-socket arthroplasty at the cervical level in vivo in terms of center of rotation between full flexion/extension (COR-FE). The spineview software (Surgiview, Paris, France) was used to investigate the intervertebral sagittal ROM and MCR in 26 Prestige LP (Medtronic Sofamor Danek, Memphis, TN) and 25 Prodisc-C (Synthes, West Chester, PA), in reference to the measurements of 200 healthy cervical discs in vivo. The COR-FE was calculated above 3 degrees in ROM. The ROM was significantly reduced with both types of arthroplasty when compared with the control group. Although the ROM was similar with both types of prosthesis, the location of the COR-FE was significantly influenced by the type of intervertebral disc despite the interindividual variability. Although the COR-FE remained within the normal range in most cases, it trended to be located more anterior and superior than normal with the 2 types of prosthesis. Neither the cranial or caudal types of ball-and-socket designs did fully restore the normal mobility in terms of ROM and COR in this patient's series.Keywords
This publication has 15 references indexed in Scilit:
- Prospective randomized controlled study of the Bryan Cervical Disc: early clinical results from a single investigational siteJournal of Neurosurgery: Spine, 2006
- Kinematic Analysis of the Cervical Spine Following Implantation of an Artificial Cervical DiscSpine, 2005
- Cervical Disc ReplacementSpine, 2005
- Validation of new clinical quantitative analysis software applicable in spine orthopaedic studiesEuropean Spine Journal, 2005
- Cervical Total Disc Replacement, Part Two: Clinical ResultsOrthopedic Clinics of North America, 2005
- The Bryan cervical disc prosthesis as an alternative to arthrodesis in the treatment of cervical spondylosisThe Journal of Bone and Joint Surgery. British volume, 2005
- Early results after ProDisc-C cervical disc replacementJournal of Neurosurgery: Spine, 2005
- Intermediate Follow-up After Treatment of Degenerative Disc Disease With the Bryan Cervical Disc Prosthesis: Single-Level and Bi-LevelSpine, 2003
- Clinical Validation of Functional Flexion/Extension Radiographs of the Cervical SpineSpine, 1993
- Abnormal Instantaneous Axes of Rotation in Patients with Neck PainSpine, 1992