MRMarc-Antoine Rousseau

Marc-Antoine Rousseau

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marc-Antoine Rousseau has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sacropelvic Fixation With Iliosacral Screws

    by Mourad Ould-Slimane, Lotfi Miladi, Marc-Antoine Rousseau, Raphael Bonaccorsi, Yves Catonne, Jean-Yves Lazennec, Hugues Pascal-Moussellard

    Study Design: Retrospective radiographic and clinical review. Objective: To determine the feasibility of iliosacral screw fixation in adult spinal deformations. Summary of Background Data: Pelvic fixation is one of the most challenging instrumentation problems. The poor bone quality frequently found within the sacrum and the large lumbosacral loads with cantilever pullout forces across this region explain its frequent failure. Methods: Fourteen adult patients undergoing pelvic fixation using iliosacral screws with a minimal follow-up of 24 months were analyzed for radiographic outcomes. Radiographic data included the localization of the spinal deformity, the Cobb angle, T4-T12 thoracic kyphosis, L1-S1 lumbar lordosis, the T9 tilt, the pelvic parameters, and the POA. Mechanical and infectious complications were also noted. Results: The lumbo-pelvic correction was performed with a large reduction of the POA in every case. The frontal and sagittal corrections obtained with this procedure were considered as being effective. There were no mechanical complications due to failure of the instrumentation, loss of sacral fixation, or loss of lumbar lordosis at the time of the last follow-up. One patient experienced local infection on the left iliosacral screw without any residual functional sequel. Discussion: Iliosacral screwing can offer a pelvic fixation reliable enough to allow restoration of 3-dimensional trunk balance. This technique has a quite short learning curve and adequately permits frontal and sagittal corrections, increases stability, and decreases instrumentation-related complications. Our observations suggest that it is applicable to pelvic fixation in adult surgery.


  • PARAMETERIZED LOWER CERVICAL SPINE MODELING FOR RECONSTRUCTION FROM BIPLANAR X-RAYS

    by Zacaria Essaïdi, Marc Antoine Rousseau, Sébastien Laporte, Thomas Joubert, Wafa Skalli

  • Influence of the Geometry of a Ball-and-Socket Intervertebral Prosthesis at the Cervical Spine

    by Marc-Antoine Rousseau, Xavier Bonnet, Wafa Skalli

    A conceptual study of the influence of the geometry of an articulated disc prosthesis at the cervical level using a 3-dimensional nonlinear finite element model. To investigate how the mechanical behavior of the functional spinal unit is affected by the position of the center and the size of the radius of a ball-and-socket design at the cervical level. Little is known about the changes in kinematics and internal efforts after intervertebral disc replacement at the cervical spine, specifically regarding the influence of the geometry of the articulated prosthesis. A ball-and-socket artificial disc was integrated in a validated 3-dimensional nonlinear finite element model of the cervical spine (posterior geometric center, large radius). The model was loaded in flexion, extension, lateral bending, and axial torsion. Two variant designs were investigated: anterior center and small radius. The intervertebral range of motion, the mean center of rotation, and the contact forces in the facet joints and in the bearing surface of the prosthesis were investigated. The range of motion was similar with all prostheses. The posterior geometric center was associated with an adequate mean center of rotation in flexion/extension. The large radius of curvature was associated with the partial unloading of the facet joints and the redistribution of the constraints at the ball-and-socket interface. Our data estimate the influence of the geometrical parameters of a ball-and-socket total disc replacement on kinematics and constraints at the cervical functional spinal unit. Under the experimental conditions, the facet forces were kept below their normal range in the case of the posterior center and a large radius.


  • In Vivo Kinematics of Two Types of Ball-and-Socket Cervical Disc Replacements in the Sagittal Plane

    by Marc-Antoine Rousseau, Philippe Cottin, Stéphane Levante, Nogier Alexis, Jean-Yves Lazennec, Wafa Skalli

    A computer-assisted analysis of dynamic lateral radiographs of the cervical spine in flexion/extension after total disc replacement. To analyze the in vivo kinematics of 2 types of ball-and-socket cervical disc arthroplasties. Clinical outcomes and range of motion (ROM) after cervical disc replacement have been documented in few studies. To our knowledge, no article reports the biomechanical behavior of any type of ball-and-socket arthroplasty at the cervical level in vivo in terms of center of rotation between full flexion/extension (COR-FE). The spineview software (Surgiview, Paris, France) was used to investigate the intervertebral sagittal ROM and MCR in 26 Prestige LP (Medtronic Sofamor Danek, Memphis, TN) and 25 Prodisc-C (Synthes, West Chester, PA), in reference to the measurements of 200 healthy cervical discs in vivo. The COR-FE was calculated above 3 degrees in ROM. The ROM was significantly reduced with both types of arthroplasty when compared with the control group. Although the ROM was similar with both types of prosthesis, the location of the COR-FE was significantly influenced by the type of intervertebral disc despite the interindividual variability. Although the COR-FE remained within the normal range in most cases, it trended to be located more anterior and superior than normal with the 2 types of prosthesis. Neither the cranial or caudal types of ball-and-socket designs did fully restore the normal mobility in terms of ROM and COR in this patient's series.


  • Long Term Outcomes after Arthroscopic Management of Tibial Plateau Fractures

    by Marc-Antoine Rousseau, Gregory Biette, Franck Jouve, Nicolas Graveleau, Philippe Hardy


  • Circumferential Arthrodesis Using PEEK Cages at the Lumbar Spine

    by Marc-Antoine Rousseau, Jean-Yves Lazennec, Gérard Saillant

    Usual interbody cages at the lumbar spine are made of titanium or carbon fiber-polyetheretherketone (PEEK). Pure PEEK cages have more recently been proposed for its lower elasticity modulus. The goal of our study was to investigate a series of patients with circumferential fixation using anterior PEEK cages for degenerative lumbar spine disorders with a specific interest in the local lordosis. Fifty-seven consecutive patients aged 54.6 years (29 to 75) were reviewed. The level of arthrodesis varied from L2L3 to L5S1. The clinical status and the radiologic variations in local lordosis at the level of arthrodesis were measured. Decrease in lordosis at follow-up was tested in a multivariate analysis regarding age, obesity, spinal level, bone graft amount, type of posterior instrumentation, postoperative lordosis increase, and cage height. The average follow-up was 5.7 years (4 to 8). Clinical outcomes were excellent or good in 49 cases. Fusion was definite in 56 cases. Although 47 patients had no change in lordosis after surgery, 10 cases showed lordosis increase (8.2 degrees; 5 to 12). At follow-up, local lordosis decreased in 13 cases (5.6 degrees; 4 to 8). The linear model was significant (PR2=0.590) showing that loss in lordosis was related with postoperative lordosis increase (P=0.01), cage height (PP=0.026), age (P=0.047), and low level (P=0.013). Lumbar circumferential arthrodesis using PEEK cages provided good clinical results and fusion rate. However, lordosis correction was not maintained at follow-up, especially at lower levels, using high cages, in older patients, and when associated with a rigid primary posterior instrumentation. Regarding the last point, this is likely that the order of the instrumentation (posterior first, then anterior) played a role in the loss of lordosis in case of rigid posterior fixation.


  • Early mechanical failure in total knee arthroplasty

    by Marc-Antoine Rousseau, Jean-Yves Lazennec, Yves Catonné

    Early mechanical dysfunction of a total knee arthroplasty (TKA) is a challenging problem in terms of causality and solutions. The current strategy in our department is to perform a complete TKA revision rather than the less invasive partial procedures when a clear mechanical cause of failure has been found. In this investigation, we assessed 21 patients who underwent complete TKA revision in 2003–2004 in our institution within the first two years following the index TKA. Various clinical presentations included pain, stiffness, instability, and femoro-patellar signs. These corresponded to implant size, position, and fixation issues. The IKS knee score/function significantly increased from 47/47 to 85/78 at follow-up (six months minimum). Compared to the data in the literature, this systematic full revision seems to be a reasonable approach. This attitude takes advantage of the modularity of the implants for allowing perioperative adjustments of position, fixation, and constraint. Based on the results of our study, we propose a list of six mechanical pitfalls to be evaluated in the case of early dysfunction: frontal misalignment, sagittal overstuffing or malpositioning, axial malrotation, poor bone fixation, inappropriate constraint or ligamentous balance, and inappropriate level of the joint space.


  • Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model

    by Jean Y. Lazennec, Abdallah Madi, Marc A. Rousseau, Bernard Roger, Gérard Saillant

    Arthrodesis using interbody cages has demonstrated high fusion rates. However, permanent cages are exposed to stress-shielding, corrosion, and may require explanation when necessary. Polylactic acid (PLA) bioresorbable cages are developed for avoiding these problems, but significant tissue reaction has been reported with 70/30 PLDLLA in some preclinical animal studies. The objective was to evaluate 96/4 PLDLLA cages in a sheep model over 3 years. Sixteen sheeps underwent one level anterior lumbar interbody fusion using 96/4 PLDLLA cages, filled and surrounded with cancellous bone graft from the iliac crest. Six groups of three animals were killed after 3, 6, 9, 12, 24, and 36 months. Harvested lumbar spine had radiographic, MRI, and CT evaluation and histological analysis. Histological results: cage swelling and slight signs of fragmentation associated to fibrocartilaginous tissue apposition at 3 months; bone remodeling around the cage with direct apposition of the mineralization front at 6 months; active cage degradation and complete fusion around the cage at 9 months; cage fragmentation and partial replacement by bone tissue at 12 months; bone bridges in and around the cage at 24 months; full resorption and intervertebral fusion at 36 months. Radiological results: partial arthrodesis at 3 months; definite peripheral arthrodesis at 6 months; similar aspect at 9 months; significant cage resorption at 12 months; definite inner and outer fusion at 24 months; complete cage resorption and calcification at the location of the cage at 36 months confirmed histological observations. Radiographic, CT scan, MRI, and histological data were consistent for showing progressive resorption of 96/4 PLDLLA, interbody fusion, and bone remodeling, with no significant signs of local intolerance reaction. These results are promising and suggest further development of 96/4 PLDLLA cages.


  • Two-stage surgical procedure for treating pelvic malunions

    by Marc-Antoine Rousseau, Frédéric Laude, Jean-Yves Lazennec, Gérard Saillant, Yves Catonné

    When surgically treated, pelvic-ring deformities due to post-traumatic malunions in adults usually require invasive three-stage (prone/supine/prone or supine/prone/supine) procedures. A standardised two-stage prone/supine procedure was developed by the authors. Technical points and first clinical results are presented. Malunuions related to Tile B and C types of fracture were successfully corrected. lorsque les fractures du bassin avec déformation de l’anneau pelvien nécessitent un traitement chirurgical il peut en résulter des pseudarthroses ou des cals vicieux chez l’adulte, qui nécessitent, habituellement un traitement en trois temps. Un traitement standardisé en deux temps a été développé par les auteurs. Les points techniques et les premiers résultats cliniques en sont présentés. Les pseudarthroses ou les cals vicieux secondaires aux fractures de type Tile B ou C ont été traitées correctement et avec succès.


  • Acute Paralyzing Sciatica due to Traumatic Lumbar Disk Herniation in a Grass Hockey Player

    by Marc-Antoine Rousseau, Hugues Pascal-Mousselard, Salima Bellefqih, Delphine Zeitoun, Gérard Saillant