First clinical experiences with a high field 1.5 T MR linac
- 26 June 2019
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 58 (10) , 1352-1357
Abstract
Purpose: A 1.5 T MR Linac (MRL) has recently become available. MRL treatment workflows (WF) include online plan adaptation based on daily MR images (MRI). This study reports initial clinical experiences after five months of use in terms of patient compliance, cases, WF timings, and dosimetric accuracy. Method and materials: Two different WF were used dependent on the clinical situation of the day; Adapt To Position WF (ATP) where the reference plan position is adjusted rigidly to match the position of the targets and the OARs, and Adapt To Shape WF (ATS), where a new plan is created to match the anatomy of the day, using deformable image registration. Both WFs included three 3D MRI scans for plan adaptation, verification before beam on, and validation during IMRT delivery. Patient compliance and WF timings were recorded. Accuracy in dose delivery was assessed using a cylindrical diode phantom. Results: Nineteen patients have completed their treatment receiving a total of 176 fractions. Cases vary from prostate treatments (60Gy/20F) to SBRT treatments of lymph nodes (45 Gy/3F) and castration by ovarian irradiation (15 Gy/3F). The median session time (patient in to patient out) for 127 ATPs was 26 (21–78) min, four fractions lasted more than 45 min due to additional plan adaptation. For the 49 ATSs a median time of 12 (1–24) min was used for contouring resulting in a total median session time of 42 (29–91) min. Three SBRT fractions lasted more than an hour. The time on the MRL couch was well tolerated by the patients. The median gamma pass rate (2 mm,2% global max) for the adapted plans was 99.2 (93.4–100)%, showing good agreement between planned and delivered dose. Conclusion: MRL treatments, including daily MRIs, plan adaptation, and accurate dose delivery, are possible within a clinically acceptable timeframe and well tolerated by the patients.Keywords
Funding Information
- MANTRA
- Odense University Hospital, Denmark
This publication has 22 references indexed in Scilit:
- Repeated diffusion MRI reveals earliest time point for stratification of radiotherapy response in brain metastasesPhysics in Medicine & Biology, 2017
- An MRI-based mid-ventilation approach for radiotherapy of the liverRadiotherapy and Oncology, 2016
- The MRI-Linear Accelerator Consortium: Evidence-Based Clinical Introduction of an Innovation in Radiation Oncology Connecting Researchers, Methodology, Data Collection, Quality Assurance, and Technical DevelopmentFrontiers in Oncology, 2016
- The development of the MRI linac system for online MRI‐guided radiotherapy: a clinical updateJournal of Internal Medicine, 2016
- Performance of a cylindrical diode array for use in a 1.5 T MR-linacPhysics in Medicine & Biology, 2016
- The evaluation of innovation in radiation oncology – what can we do and what should we do?Acta Oncologica, 2015
- Multicentre knowledge sharing and planning/dose audit on flattening filter free beams for SBRT lungJournal of Physics: Conference Series, 2015
- MR guidance in radiotherapyPhysics in Medicine & Biology, 2014
- Plan quality and delivery accuracy of flattening filter free beam for SBRT lung treatmentsActa Oncologica, 2014
- MRI/linac integrationRadiotherapy and Oncology, 2008