Comparison of Single Layer and Bilayer Biosensors Based on Crosslinking of Penicillinase for Potentiometric Detection of Penicillin in Milk and Antibiotics
- 25 March 2015
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 27 (6) , 1523-1531
Abstract
The use of bilayers for fabrication of biosensors is advantageous for increasing enzyme loading. Substantial improvement in sensitivity is often achieved through immobilisation of the enzyme in both layers. In particular, the use of cross linking agents such as glutaraldehyde (GLA), bovine serum albumin (BSA) and polyvinyl alcohol (PVA) are beneficial for enhancing enzyme stability and, hence, for fabricating stable biosensors. The successful fabrication of a single layer BSA‐GLA‐P’nase biosensor for potentiometric detection of penicillin is described. Subsequently, the three crosslinking agents were employed with two polymers, polypyrrole (PPy) and polytyramine (PTy), together with penicillinase (P’nase) for fabrication of PPy‐NO3‐P’nase/BSA‐PVA‐P’nase and PTy‐NO3‐P’nase/BSA‐GLA‐P’nase bilayer biosensors. The analytical performances of the bilayer biosensors were then compared with the single layer BSA‐GLA‐P’nase biosensor for the determination of penicillin in milk and amoxycillin tablets. While the determination of penicillin in milk was somewhat problematic, its determination in amoxicillin tablets proved to be successful, with recoveries of 102±15 % obtained with the PPy‐NO3‐P’nase/BSA‐PVA‐P’nase biosensor, 100±19 % with PTy‐NO3‐P’nase/BSA‐GLA‐P’nase biosensor and 103±5 % with BSA‐GLA‐P’nase biosensor. Notably, the results of the latter agreed favourably with those obtained through a reference titrimetric method.Keywords
This publication has 29 references indexed in Scilit:
- Potentiometric properties of polypyrrole bilayersElectrochimica Acta, 2004
- Food processing effects on residues: penicillins in milk and yoghurtAnalytica Chimica Acta, 2003
- NADH and glutamate on-line sensors using Os-gel-HRP/GC electrodes modified with NADH oxidase and glutamate dehydrogenaseBiosensors and Bioelectronics, 1999
- In situ preparation of overoxidized PPy/oPPD bilayer biosensors for the determination of glucose and cholesterol in serumSensors and Actuators B: Chemical, 1999
- Effective Charge Trapping in Bilayers of Conducting Polymers Based on Polypyrrole and Poly(N-methylpyrrole)Electroanalysis, 1998
- Flow-through tyrosinase enzyme reactor based on reticulated vitreous carbon functionalized by an electrochemically synthesized filmAnalytica Chimica Acta, 1996
- Intracellular analysis with an immobilized-enzyme glucose electrode having a 2-.mu.m diameter and subsecond response timesJournal of the American Chemical Society, 1991
- Amperometric glucose sensor based on glucose dehydrogenase immobilized on a graphite electrode modified with an N,N′-bis(benzophenoxazinyl) derivative, of benzene-1,4-dicarboxamideAnalytica Chimica Acta, 1991
- Direct titrations of antibiotics with iodate solutionAnalytica Chimica Acta, 1979
- Determination of penicillins by desulphurization with lead and edta titrationTalanta, 1979