Abstract
This study aims to test the reliability of ultrasound to graduate synovitis in static and video images, evaluating separately grayscale and power Doppler (PD), and combined. Thirteen trained rheumatologist ultrasonographers participated in two separate rounds reading 42 images, 15 static and 27 videos, of the 7-joint count [wrist, 2nd and 3rd metacarpophalangeal (MCP), 2nd and 3rd interphalangeal (IPP), 2nd and 5th metatarsophalangeal (MTP) joints]. The images were from six patients with rheumatoid arthritis, performed by one ultrasonographer. Synovitis definition was according to OMERACT. Scoring system in grayscale, PD separately, and combined (GLOESS—Global OMERACT-EULAR Score System) were reviewed before exercise. Reliability intra- and inter-reading was calculated with Cohen’s kappa weighted, according to Landis and Koch. Kappa values for inter-reading were good to excellent. The minor kappa was for GLOESS in static images, and the highest was for the same scoring in videos (k 0.59 and 0.85, respectively). Excellent values were obtained for static PD in 5th MTP joint and for PD video in 2nd MTP joint. Results for GLOESS in general were good to moderate. Poor agreement was observed in 3rd MCP and 3rd IPP in all kinds of images. Intra-reading agreement were greater in grayscale and GLOESS in static images than in videos (k 0.86 vs. 0.77 and k 0.86 vs. 0.71, respectively), but PD was greater in videos than in static images (k 1.0 vs. 0.79). The reliability of the synovitis scoring through static images and videos is in general good to moderate when using grayscale and PD separately or combined.Keywords
This publication has 38 references indexed in Scilit:
- The ability of synovitis to predict structural damage in rheumatoid arthritis: a comparative study between clinical examination and ultrasoundAnnals of the Rheumatic Diseases, 2013
- Prediction of Radiographic Damage in Early Arthritis by Sonographic Erosions and Power Doppler Signal: A Longitudinal Observational StudyArthritis Care & Research, 2012
- Reliability of patient self‐evaluation of swollen and tender joints in rheumatoid arthritis: A comparison study with ultrasonography, physician, and nurse assessmentsArthritis Care & Research, 2010
- Intratendinous Power Doppler Changes Related to Patient Position in Seronegative SpondyloarthritisThe Journal of Rheumatology, 2010
- Influence of recent exercise and skin temperature on ultrasound Doppler measurements in patients with rheumatoid arthritis--an intervention studyRheumatology, 2009
- The effect of joint position on Doppler flow in finger synovitisAnnals of the Rheumatic Diseases, 2009
- Assessing the intra- and inter-reader reliability of dynamic ultrasound images in power Doppler ultrasonographyAnnals of the Rheumatic Diseases, 2006
- Assessment of inflammatory activity in rheumatoid arthritis: a comparative study of clinical evaluation with grey scale and power Doppler ultrasonographyAnnals of the Rheumatic Diseases, 2005
- Ultrasonography of the metatarsophalangeal joints in rheumatoid arthritis: Comparison with magnetic resonance imaging, conventional radiography, and clinical examinationArthritis & Rheumatism, 2004
- Arthritis of the finger joints: A comprehensive approach comparing conventional radiography, scintigraphy, ultrasound, and contrast-enhanced magnetic resonance imagingArthritis & Rheumatism, 1999