Characterization of electron beams emitted from dense plasma focus machines using argon, neon and nitrogen
Authors:
- 20 November 2018
- journal article
- research article
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 32 (32)
Abstract
The measured current traces of two low energy machines namely the AECS PF-2 and INTI PF are used for studying of the produced electron beam features using the modified Lee code (RADPFV5.15REB) at different conditions. The fitting procedures between measured and computed current traces are made for each point of pressure. In the case of AECS PF-2 working with neon, the electron fluence reaches the maximum value [Formula: see text] electrons m[Formula: see text] for 1.6 Torr and the flux achieves [Formula: see text] electrons m[Formula: see text]s[Formula: see text] near 1.5 Torr. The electron number has a peak of [Formula: see text] at 0.9 Torr. The computed results demonstarte also the maximum value of the power flow density of [Formula: see text] Wm[Formula: see text], and the superior damage factor of around [Formula: see text] Wm[Formula: see text]s[Formula: see text] at a pressure of 0.4 Torr. Argon presents the action of radiative cooling topping at highly magnified [Formula: see text] m[Formula: see text]s[Formula: see text] at 0.9 Torr. The damage factor reaches almost [Formula: see text] Wm[Formula: see text]s[Formula: see text] for Ar but it is only [Formula: see text] Wm[Formula: see text]s[Formula: see text] for N2. The huge values for argon are a result of enhanced compression due to radiative cooling. In the case of INTI PF device, the electron energy extends from 58 keV (for N2) to 256 keV (for Ar). The results indicate that the electron fluence ranges from [Formula: see text] electrons m[Formula: see text] for N2 to [Formula: see text] electrons m[Formula: see text] for Ar.Keywords
This publication has 24 references indexed in Scilit:
- Plasma dynamics in the PF-1000 device under full-scale energy storage: II. Fast electron and ion characteristics versus neutron emission parameters and gun optimization perspectivesJournal of Physics D: Applied Physics, 2007
- Effect of Anode Designs on Ion Emission Characteristics of a Plasma Focus DeviceJapanese Journal of Applied Physics, 2007
- Optimization of a plasma focus device as an electron beam source for thin film depositionPlasma Sources Science and Technology, 2007
- Nitriding of titanium by using an ion beam delivered by a plasma focusJournal of Physics D: Applied Physics, 2007
- Development of Multi Faraday Cup Assembly for Ion Beam Measurements from a Low Energy Plasma Focus DeviceJapanese Journal of Applied Physics, 2005
- Relativistic electron beams detection in a dense plasma focusThe European Physical Journal D, 2002
- Hot-spots in plasma-focus discharges as intense sources of different radiation pulsesBrazilian Journal of Physics, 2002
- Small plasma focus studied as a source of hard X-rayIEEE Transactions on Plasma Science, 2001
- Electron lithography using a compact plasma focusPlasma Sources Science and Technology, 1997
- A Method for Measuring Electron Energy Distribution in a Plasma FocusJapanese Journal of Applied Physics, 1990