Sor Heoh Saw
Research Subjects
Sor Heoh Saw has a total of 137 co-authors. Here are the top co-authors by number of shared publications:
S. Lee
INTI International University, Nilai 71800, Malaysia, also with the Institute for Plasma Focus Studies, Melbourne, VIC 3148, Australia, and also with the University of Malaya, Kuala Lumpur 50603, Malaysia
32 shared publications- Sing Lee
INTI International University, 71800 Nilai, Malaysia
23 shared publications Sing Lee
Institute Plasma Focus Studies, Melbourne
16 shared publications- Paul Lee
Natural Sciences and Science Education, National Institute of Education, Nanyang Technological University, Singapore
15 shared publications - Rajdeep Singh Rawat
Natural Sciences and Science Education National Institute of Education Nanyang Technological University Singapore Singapore
15 shared publications - Mohamad Akel
Atomic Energy Commission of Syria
12 shared publications
Latest Publications
- Open Access
- 1 October 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (10)
Total neutron emission from deuteron fusion and plasma pinch compression in a medium-sized plasma focus operating with D2 and D2 + Ne gas mixtures—Experimental results
Newly obtained results on hot and dense deuterium and deuterium-neon plasma compression in a z-pinch electrical discharge configuration are presented. The investigated plasma was generated and compressed using 269 high-current discharges in a medium-sized (dense) plasma focus device. The experimental chamber of the device was filled with deuterium and deuterium-neon gas mixtures under constant total mass/density conditions. Magnetic and electric probes, beryllium neutron activation counter, and high-speed four-frame vacuum ultraviolet/soft x-ray pinhole camera were used to study the plasma dynamics and radiation emission. The results obtained experimentally for the first time confirmed clearly a decrease in the minimum radius of plasma columns with an increase in initial neon fraction. Simultaneously, a decrease in the total neutron emission from deuteron fusion was found. The observed plasma/discharge evolution revealed that the classical description of plasma-focus discharges can be approximately correct up to the moment of maximum compression. Including, existence of quasi-equilibrium plasma compression is probable. It is also possible that the homogeneity of plasma columns during the slow compression phase and maximum compression moment increases with the increase in initial neon fraction. The effect of higher stabilization (repeatability) of discharges was confirmed, for higher initial neon fractions. The dependency of the total neutron emission yield on the parameters describing the full discharge dynamics and the maximum discharge voltage was confirmed. The existence of this type of dependency, for a minimum pinch radius is also possible. In contrast, there was little dependency to the total discharge current parameters measured in the collector area.
- 1 October 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (10)
Open AccessTotal neutron emission from deuteron fusion and plasma pinch compression in a medium-sized plasma focus operating with D2 and D2 + Ne gas mixtures—Experimental results
Newly obtained results on hot and dense deuterium and deuterium-neon plasma compression in a z-pinch electrical discharge configuration are presented. The investigated plasma was generated and compressed using 269 high-current discharges in a medium-sized (dense) plasma focus device. The experimental chamber of the device was filled with deuterium and deuterium-neon gas mixtures under constant total mass/density conditions. Magnetic and electric probes, beryllium neutron activation counter, and high-speed four-frame vacuum ultraviolet/soft x-ray pinhole camera were used to study the plasma dynamics and radiation emission. The results obtained experimentally for the first time confirmed clearly a decrease in the minimum radius of plasma columns with an increase in initial neon fraction. Simultaneously, a decrease in the total neutron emission from deuteron fusion was found. The observed plasma/discharge evolution revealed that the classical description of plasma-focus discharges can be approximately correct up to the moment of maximum compression. Including, existence of quasi-equilibrium plasma compression is probable. It is also possible that the homogeneity of plasma columns during the slow compression phase and maximum compression moment increases with the increase in initial neon fraction. The effect of higher stabilization (repeatability) of discharges was confirmed, for higher initial neon fractions. The dependency of the total neutron emission yield on the parameters describing the full discharge dynamics and the maximum discharge voltage was confirmed. The existence of this type of dependency, for a minimum pinch radius is also possible. In contrast, there was little dependency to the total discharge current parameters measured in the collector area.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2530 (1)
Hardening AISI 316 steel using INTI dense plasma focus machine
Surface modification of material has been an ongoing process since the iron age as can be observed in the process of making iron tools and weapons. Today the methods of material hardening have become much more varied and include nitriding, carburizing, boriding and various heat treatment. In this paper, a study on hardness improvement using nitriding on AISI 316 steel using INTI Plasma Focus Machine was carried out. The plasma dynamics was analysed with the aid of the Lee model code and it was found that the energy produced by the plasma focus machine was 4 Joules while 12 shots was needed to improve the hardness of the steel by 30% when the plasma focus was set at a pressure of 1 torr nitrogen gas and the sample was placed 40 mm from the anode tip.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2530 (1)
Open AccessHardening AISI 316 steel using INTI dense plasma focus machine
Surface modification of material has been an ongoing process since the iron age as can be observed in the process of making iron tools and weapons. Today the methods of material hardening have become much more varied and include nitriding, carburizing, boriding and various heat treatment. In this paper, a study on hardness improvement using nitriding on AISI 316 steel using INTI Plasma Focus Machine was carried out. The plasma dynamics was analysed with the aid of the Lee model code and it was found that the energy produced by the plasma focus machine was 4 Joules while 12 shots was needed to improve the hardness of the steel by 30% when the plasma focus was set at a pressure of 1 torr nitrogen gas and the sample was placed 40 mm from the anode tip.
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (9) , 4301-4311
Investigation of the Measured and Computed Neutron Yield From the PF-24 Device Operated With D2-$x$ %Ar Admixture
Many experiments have been carried out on the (16.8 kJ, 17 kV) dense plasma focus PF-24 device operated with pure deuterium and deuterium-argon admixture. The main purpose of the work was to investigate the influence of the doping argon on the average total neutron yields experimentally and numerically. The 103 discharges (34 for D₂, 69 for D₂-x%Ar, where x = 3, 5, 10, 15, 22, 25, 30, 45, 60) were performed in four experimental sessions under constant total initial optimum pressure of about 2.2 torr. The total current and its time derivative traces, as well as the total neutron yield values, were recorded, and the electro-kinetic plasma parameters were estimated for each shot. The Lee model has also been adapted for gas mixture plasma focus modeling, and then the enhanced code was used for simulation of each of the PF-24 discharge with D₂ and D₂-x%Ar. The fitting parameters for each shot are found and discussed. The measured and computed values of the neutron yield and the electro-kinetic plasma parameters are in good agreement. The obtained results showed that there is no neutron yield enhancement with argon seeding. The scaling law of the neutron yield Yn against argon fraction has been deduced. Additionally, our results illustrate that the PF-24 plasma focus device has an optimized configuration for the DD fusion neutron emission.
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 47 (9) , 4301-4311
Investigation of the Measured and Computed Neutron Yield From the PF-24 Device Operated With D2-$x$ %Ar Admixture
Many experiments have been carried out on the (16.8 kJ, 17 kV) dense plasma focus PF-24 device operated with pure deuterium and deuterium-argon admixture. The main purpose of the work was to investigate the influence of the doping argon on the average total neutron yields experimentally and numerically. The 103 discharges (34 for D₂, 69 for D₂-x%Ar, where x = 3, 5, 10, 15, 22, 25, 30, 45, 60) were performed in four experimental sessions under constant total initial optimum pressure of about 2.2 torr. The total current and its time derivative traces, as well as the total neutron yield values, were recorded, and the electro-kinetic plasma parameters were estimated for each shot. The Lee model has also been adapted for gas mixture plasma focus modeling, and then the enhanced code was used for simulation of each of the PF-24 discharge with D₂ and D₂-x%Ar. The fitting parameters for each shot are found and discussed. The measured and computed values of the neutron yield and the electro-kinetic plasma parameters are in good agreement. The obtained results showed that there is no neutron yield enhancement with argon seeding. The scaling law of the neutron yield Yn against argon fraction has been deduced. Additionally, our results illustrate that the PF-24 plasma focus device has an optimized configuration for the DD fusion neutron emission.
- 10 March 2019
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 33 (07)
Optimization of neon soft X-ray yield in a low-energy dense plasma focus device
- 10 March 2019
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 33 (07)
Optimization of neon soft X-ray yield in a low-energy dense plasma focus device
- Open Access
- 24 November 2018
- Published by College of Graduate Studies, Walailak University in Walailak Journal of Science and Technology (WJST)
- Vol. 16 (6) , 369-377
Current-Voltage Characteristics of the Plasma Focus: A Deeper Look
A capacitor bank discharges a current which is a sinusoidal function, lightly damped by unavoidable circuit resistance. When powering a plasma focus, the current waveform is further damped by the axial motion typically during the rising part of the current. The radial phase, with severe rate of change of inductance due to a rapidly collapsing current sheet to a small radius, is so severely damped over a short period near the current peak that the waveform goes into the sharp dip. This produces the well-known signature current dip of the properly-operated plasma focus. Corresponding to the inductively-caused current dip is a sharp voltage spike which typically rises to a peak value in excess of the voltage to which the capacitor is charged. These features are adequately described by circuit equations coupled to appropriate equations of motion. The loading effect of different gases due to differences in mass, differences in compressibility and differences in radiation also produces differences in the current waveforms particularly in the current dips and voltage spikes. These differences could be subtle or dramatic, as are demonstrated in this paper.
- 24 November 2018
- Published by College of Graduate Studies, Walailak University in Walailak Journal of Science and Technology (WJST)
- Vol. 16 (6) , 369-377
Open AccessCurrent-Voltage Characteristics of the Plasma Focus: A Deeper Look
A capacitor bank discharges a current which is a sinusoidal function, lightly damped by unavoidable circuit resistance. When powering a plasma focus, the current waveform is further damped by the axial motion typically during the rising part of the current. The radial phase, with severe rate of change of inductance due to a rapidly collapsing current sheet to a small radius, is so severely damped over a short period near the current peak that the waveform goes into the sharp dip. This produces the well-known signature current dip of the properly-operated plasma focus. Corresponding to the inductively-caused current dip is a sharp voltage spike which typically rises to a peak value in excess of the voltage to which the capacitor is charged. These features are adequately described by circuit equations coupled to appropriate equations of motion. The loading effect of different gases due to differences in mass, differences in compressibility and differences in radiation also produces differences in the current waveforms particularly in the current dips and voltage spikes. These differences could be subtle or dramatic, as are demonstrated in this paper.
- 20 November 2018
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 32 (32)
Characterization of electron beams emitted from dense plasma focus machines using argon, neon and nitrogen
The measured current traces of two low energy machines namely the AECS PF-2 and INTI PF are used for studying of the produced electron beam features using the modified Lee code (RADPFV5.15REB) at different conditions. The fitting procedures between measured and computed current traces are made for each point of pressure. In the case of AECS PF-2 working with neon, the electron fluence reaches the maximum value [Formula: see text] electrons m[Formula: see text] for 1.6 Torr and the flux achieves [Formula: see text] electrons m[Formula: see text]s[Formula: see text] near 1.5 Torr. The electron number has a peak of [Formula: see text] at 0.9 Torr. The computed results demonstarte also the maximum value of the power flow density of [Formula: see text] Wm[Formula: see text], and the superior damage factor of around [Formula: see text] Wm[Formula: see text]s[Formula: see text] at a pressure of 0.4 Torr. Argon presents the action of radiative cooling topping at highly magnified [Formula: see text] m[Formula: see text]s[Formula: see text] at 0.9 Torr. The damage factor reaches almost [Formula: see text] Wm[Formula: see text]s[Formula: see text] for Ar but it is only [Formula: see text] Wm[Formula: see text]s[Formula: see text] for N2. The huge values for argon are a result of enhanced compression due to radiative cooling. In the case of INTI PF device, the electron energy extends from 58 keV (for N2) to 256 keV (for Ar). The results indicate that the electron fluence ranges from [Formula: see text] electrons m[Formula: see text] for N2 to [Formula: see text] electrons m[Formula: see text] for Ar.
- 20 November 2018
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 32 (32)
Characterization of electron beams emitted from dense plasma focus machines using argon, neon and nitrogen
The measured current traces of two low energy machines namely the AECS PF-2 and INTI PF are used for studying of the produced electron beam features using the modified Lee code (RADPFV5.15REB) at different conditions. The fitting procedures between measured and computed current traces are made for each point of pressure. In the case of AECS PF-2 working with neon, the electron fluence reaches the maximum value [Formula: see text] electrons m[Formula: see text] for 1.6 Torr and the flux achieves [Formula: see text] electrons m[Formula: see text]s[Formula: see text] near 1.5 Torr. The electron number has a peak of [Formula: see text] at 0.9 Torr. The computed results demonstarte also the maximum value of the power flow density of [Formula: see text] Wm[Formula: see text], and the superior damage factor of around [Formula: see text] Wm[Formula: see text]s[Formula: see text] at a pressure of 0.4 Torr. Argon presents the action of radiative cooling topping at highly magnified [Formula: see text] m[Formula: see text]s[Formula: see text] at 0.9 Torr. The damage factor reaches almost [Formula: see text] Wm[Formula: see text]s[Formula: see text] for Ar but it is only [Formula: see text] Wm[Formula: see text]s[Formula: see text] for N2. The huge values for argon are a result of enhanced compression due to radiative cooling. In the case of INTI PF device, the electron energy extends from 58 keV (for N2) to 256 keV (for Ar). The results indicate that the electron fluence ranges from [Formula: see text] electrons m[Formula: see text] for N2 to [Formula: see text] electrons m[Formula: see text] for Ar.
- 27 April 2018
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 37 (2-3) , 124-129
Measurements and Simulations of Neutron Emission Versus Deuterium Filling Pressure in Plasma Focus Device PF-24
- 27 April 2018
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 37 (2-3) , 124-129
Measurements and Simulations of Neutron Emission Versus Deuterium Filling Pressure in Plasma Focus Device PF-24
- 24 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (11) , 2979-2983
PF1000 High-Energy Plasma Focus Device Operated With Neon as a Copious Soft X-Ray Source
The measured current waveforms of PF1000 plasma focus operating in neon are first fitted to the computed currents using the Lee model for the pressures of 0.5 and 0.8 torr. The fitting fixes the model parameters. The code is then run to study and to optimize the soft X-ray yield from (~352 kJ) PF1000 device. The maximum characteristic soft X-ray (H-like and He-like lines) yield of 4.2 kJ is found to occur at the pressure of 0.85 torr, with the pinch duration of 207 ns and with an all-line yield of 4.8 kJ. Maximum compression (corresponding to smallest pinch radius) of 0.585 cm with the duration of 224 ns is obtained at 1 torr with the greatest all-line yield of 7.1 kJ but a lower characteristic soft X-ray yield of 3.2 kJ. Detailed computation results indicate that the maximum compression (minimum pinch radius) at 1 torr is attributed to two mechanisms: thermodynamics specific heat ratio effects and radiative losses.
- 24 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (11) , 2979-2983
PF1000 High-Energy Plasma Focus Device Operated With Neon as a Copious Soft X-Ray Source
The measured current waveforms of PF1000 plasma focus operating in neon are first fitted to the computed currents using the Lee model for the pressures of 0.5 and 0.8 torr. The fitting fixes the model parameters. The code is then run to study and to optimize the soft X-ray yield from (~352 kJ) PF1000 device. The maximum characteristic soft X-ray (H-like and He-like lines) yield of 4.2 kJ is found to occur at the pressure of 0.85 torr, with the pinch duration of 207 ns and with an all-line yield of 4.8 kJ. Maximum compression (corresponding to smallest pinch radius) of 0.585 cm with the duration of 224 ns is obtained at 1 torr with the greatest all-line yield of 7.1 kJ but a lower characteristic soft X-ray yield of 3.2 kJ. Detailed computation results indicate that the maximum compression (minimum pinch radius) at 1 torr is attributed to two mechanisms: thermodynamics specific heat ratio effects and radiative losses.
- 8 October 2017
- Published by Springer Nature
- p. 113-232
The Plasma Focus—Numerical Experiments, Insights and Applications
- 8 October 2017
- Published by Springer Nature
- p. 113-232
The Plasma Focus—Numerical Experiments, Insights and Applications