Sonography in the diagnosis of peri‐implant bone defects: An in vitro study on native human mandibles
Open Access
- 4 June 2024
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 35 (9) , 1128-1137
Abstract
Aim: The aim of this study on native human cadavers was to compare clinical, sonographic, and radiological measurements of fenestrations, dehiscences, and 3‐wall bone defects on implants.Materials and Methods: The examination was carried out on five human mandibles. After the insertion of 27 implants, dehiscences (n = 14), fenestrations (n = 7) and 3‐wall bone defects (n = 6) were prepared in a standardized manner. The direct measurement of the bone defects was carried out with a periodontal probe and the radiological examination was carried out using digital volume tomography (DVT). The ultrasound examination (US) was performed using a clinical 24‐MHz US imaging probe. Means and standard deviations of the direct, US, and DVT measurements were calculated. Measurements were statistically compared using the Pearson correlation coefficient and Bland–Altman analysis.Results: Bone defects were on average 3.22 ± 1.58 mm per direct measurement, 2.90 ± 1.47 mm using US, and 2.99 ± 1.52 mm per DVT assessment. Pairwise correlations of these measurements were R = .94 (p < .0001) between direct and US, R = .95 (p < .0001) between DVT and US, and R = .96 (p < .0001) between direct and DVT. The mean differences of the measurements (and 95% CI) between direct and US was 0.41 (−0.47 to 1.29), US and DVT 0.33 (−0.30 to 0.97), and direct and DVT 0.28 (−0.50 to 1.07).Conclusion: All peri‐implant bone defects could be identified and sonographically measured. US measurements showed a strong correlation with direct and DVT measurements. The sonographic measurement accuracy was highest for dehiscences, followed by fenestrations and 3‐wall bone defects.Keywords
This publication has 18 references indexed in Scilit:
- Doppler ultrasonographic evaluation of tissue revascularization following connective tissue graft at implant sitesJournal of Clinical Periodontology, 2023
- Influence of buccal bone wall thickness on the peri‐implant hard and soft tissue dimensional changes: A systematic reviewClinical Oral Implants Research, 2023
- Overview of Ultrasound in Dentistry for Advancing Research Methodology and Patient Care Quality with Emphasis on Periodontal/Peri-implant ApplicationsZeitschrift für Medizinische Physik, 2023
- Inaccuracy of buccal bone thickness estimation on cone‐beam CT due to implant blooming: An ex‐vivo studyJournal of Clinical Periodontology, 2019
- Morphology and severity of peri‐implantitis bone defectsClinical Implant Dentistry and Related Research, 2019
- Ultrasonography for noninvasive and real‐time evaluation of peri‐implant tissue dimensionsJournal of Clinical Periodontology, 2018
- Non‐ionizing real‐time ultrasonography in implant and oral surgery: A feasibility studyClinical Oral Implants Research, 2016
- Accuracy of periapical radiography in assessing bone level in implants affected by peri‐implantitis: a cross‐sectional studyJournal of Clinical Periodontology, 2016
- Peri‐implant health and disease. A systematic review of current epidemiologyJournal of Clinical Periodontology, 2015
- Ultrasonic Assessment of Mucosal Thickness around Implants: Validity, Reproducibility, and Stability of Connective Tissue Grafts at the Buccal AspectClinical Implant Dentistry and Related Research, 2014