Enhancement of Stopping Power Ratio (SPR) Estimation Accuracy through Image-Domain Dual-Energy Computer Tomography for Pencil Beam Scanning System: A Simulation Study
Open Access
Abstract
Our study aims to quantify the impact of spectral separation on achieved theoretical prediction accuracy of proton-stopping power when the volume discrepancy between calibration phantom and scanned object is observed. Such discrepancy can be commonly seen in our CSI pediatric patients. One of the representative image-domain DECT models is employed on a virtual phantom to derive electron density and effective atomic number for a total of 34 ICRU standard human tissues. The spectral pairs used in this study are 90 kVp/140 kVp, without and with 0.1 mm to 0.5 mm additional tin filter. The two DECT images are reconstructed via a conventional filtered back projection algorithm (FBP) on simulated noiseless projection data. The best-predicted accuracy occurs at a spectral pair of 90 kVp/140 kVp with a 0.3 mm tin filter, and the root-mean-squared average error is 0.12% for tissue substitutes. The results reveal that the selected image-domain model is sensitive to spectral pair deviation when there is a discrepancy between calibration and scanning conditions. This study suggests that an optimization process may be needed for clinically available DECT scanners to yield the best proton-stopping power estimation.Keywords
This publication has 22 references indexed in Scilit:
- Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogatesPhysics in Medicine & Biology, 2013
- Ion range estimation by using dual energy computed tomographyZeitschrift für Medizinische Physik, 2013
- Deriving effective atomic numbers from DECT based on a parameterization of the ratio of high and low linear attenuation coefficientsPhysics in Medicine & Biology, 2013
- Experimental implementation of a polyenergetic statistical reconstruction algorithm for a commercial fan-beam CT scannerPhysica Medica, 2013
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- Theoretical variance analysis of single- and dual-energy computed tomography methods for calculating proton stopping power ratios of biological tissuesPhysics in Medicine & Biology, 2010
- Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculationsPhysics in Medicine & Biology, 2008
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996
- Energy-selective reconstructions in X-ray computerised tomographyPhysics in Medicine & Biology, 1976
- Zur Theorie des Durchgangs schneller Korpuskularstrahlen durch MaterieAnnalen der Physik, 1930