Hamed Hooshangnejad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hamed Hooshangnejad has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Kai Ding
Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD 21287, USA
15 shared publications - Debarghya China
Department of Biomedical Engineering, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
6 shared publications - Rui Zhang
Division of Computational Health Sciences, Department of Surgery, University of Minnesota, Minneapolis, USA
6 shared publications - Xue Feng
Department of Biomedical Engineering University of Virginia Charlottesville Virginia USA
6 shared publications - Quan Chen
Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ 85054, USA
5 shared publications - Yi Luo
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
5 shared publications
Latest Publications
- Open Access
- 8 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16  (10) , 1441
Hybrid Curriculum Learning for Data-Efficient Lung Nodule Detection with YOLOv11
Background/Objectives: Accurate detection of pulmonary nodules on chest CT is critical for lung cancer screening, yet training robust detectors remains challenging due to the high cost of reliable annotations. In this work, we present a systematic study of curriculum learning for CT-based lung nodule detection on the enhanced LUNA25 benchmark and propose a hybrid curriculum learning framework for data-efficient optimization. Methods: Our approach estimates sample difficulty by fusing clinically interpretable handcrafted factors such as nodule size and count with model-driven signals such as prediction confidence from a teacher model, and constructs a three-stage progressive training curriculum from easy to hard samples. Using YOLOv11s as a strong baseline, the proposed hybrid curriculum is compared against conventional training without curriculum learning and against single-source curricula. Results: On the held-out LUNA25 test set, hybrid curriculum learning increases from 0.672 to 0.696, from 0.369 to 0.385, recall from 0.588 to 0.634, and precision from 0.725 to 0.764. Extensive data-efficiency experiments with proportional reductions (1/2, 1/5, 1/10) and fixed training samples (5000–40,000 slices) further confirm consistent gains across limited-data regimes. Conclusions: These results demonstrate that jointly leveraging intrinsic image complexity and optimization-aware feedback provides effective sample scheduling for robust and data-efficient lung nodule detection.- 8 May 2026
- Published by MDPI AG in Diagnostics
- Vol. 16  (10) , 1441
Open AccessHybrid Curriculum Learning for Data-Efficient Lung Nodule Detection with YOLOv11
Background/Objectives: Accurate detection of pulmonary nodules on chest CT is critical for lung cancer screening, yet training robust detectors remains challenging due to the high cost of reliable annotations. In this work, we present a systematic study of curriculum learning for CT-based lung nodule detection on the enhanced LUNA25 benchmark and propose a hybrid curriculum learning framework for data-efficient optimization. Methods: Our approach estimates sample difficulty by fusing clinically interpretable handcrafted factors such as nodule size and count with model-driven signals such as prediction confidence from a teacher model, and constructs a three-stage progressive training curriculum from easy to hard samples. Using YOLOv11s as a strong baseline, the proposed hybrid curriculum is compared against conventional training without curriculum learning and against single-source curricula. Results: On the held-out LUNA25 test set, hybrid curriculum learning increases from 0.672 to 0.696, from 0.369 to 0.385, recall from 0.588 to 0.634, and precision from 0.725 to 0.764. Extensive data-efficiency experiments with proportional reductions (1/2, 1/5, 1/10) and fixed training samples (5000–40,000 slices) further confirm consistent gains across limited-data regimes. Conclusions: These results demonstrate that jointly leveraging intrinsic image complexity and optimization-aware feedback provides effective sample scheduling for robust and data-efficient lung nodule detection. - Open Access
- 29 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13  (4) , 398
Evaluating Curvature-Induced Variation in Deep Learning-Based Beamforming for Flexible Transducers in Ultrasound-Guided Radiation Therapy
Ultrasound imaging is a crucial tool for guiding radiation therapy, particularly for cancers such as pancreatic cancer, where tumors exhibit respiration-induced motion. While flexible ultrasound transducers offer improved anatomical conformity and reduced compression-induced distortion compared to rigid probes, their variable geometry presents significant challenges for conventional beamforming. In this study, we investigate a deep learning-based beamforming framework that directly predicts delayed RF data from raw RF input, bypassing explicit transducer shape estimation and traditional delay-and-sum computations. Building upon an artificial curvature simulation strategy, we systematically analyze the impact of curvature-induced variation and inherent RF noise on model performance and generalizability. We further introduce frequency-domain analysis to quantify RF-level signal variation that may not be apparent in spatial-domain image comparisons. Our results demonstrate that although noise-augmented training improves prediction consistency, reconstruction performance remains limited under the current prototype noise conditions. These findings highlight the importance of RF data diversity and noise characterization in developing clinically robust deep learning beamformers for flexible transducer-based ultrasound-guided radiation therapy.
- 29 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13  (4) , 398
Open AccessEvaluating Curvature-Induced Variation in Deep Learning-Based Beamforming for Flexible Transducers in Ultrasound-Guided Radiation Therapy
Ultrasound imaging is a crucial tool for guiding radiation therapy, particularly for cancers such as pancreatic cancer, where tumors exhibit respiration-induced motion. While flexible ultrasound transducers offer improved anatomical conformity and reduced compression-induced distortion compared to rigid probes, their variable geometry presents significant challenges for conventional beamforming. In this study, we investigate a deep learning-based beamforming framework that directly predicts delayed RF data from raw RF input, bypassing explicit transducer shape estimation and traditional delay-and-sum computations. Building upon an artificial curvature simulation strategy, we systematically analyze the impact of curvature-induced variation and inherent RF noise on model performance and generalizability. We further introduce frequency-domain analysis to quantify RF-level signal variation that may not be apparent in spatial-domain image comparisons. Our results demonstrate that although noise-augmented training improves prediction consistency, reconstruction performance remains limited under the current prototype noise conditions. These findings highlight the importance of RF data diversity and noise characterization in developing clinically robust deep learning beamformers for flexible transducer-based ultrasound-guided radiation therapy.
- Open Access
Multiscale Segmentation-Guided Diffusion Model for CBCT-to-CT Synthesis
To improve synthetic CT (sCT) generation from cone-beam CT (CBCT) in radiotherapy, we propose a multiscale segmentation-guided diffusion framework. The proposed model integrates anatomical priors across multiple spatial resolutions through a segmentation mask pyramid and introduces a scale-specific loss function to guide learning at each level. When evaluated on the SynthRAD2023 brain dataset, our model achieves a mean absolute error (MAE) of 61.82 HU, a peak signal-to-noise ratio (PSNR) of 32.05 dB, and a structural similarity index (SSIM) of 0.90, outperforming baseline models. These results suggest that multiscale anatomical guidance can improve the fidelity and anatomical consistency of sCT images, thus facilitating high-quality CBCT-to-CT translation in radiotherapy applications.
Open AccessMultiscale Segmentation-Guided Diffusion Model for CBCT-to-CT Synthesis
To improve synthetic CT (sCT) generation from cone-beam CT (CBCT) in radiotherapy, we propose a multiscale segmentation-guided diffusion framework. The proposed model integrates anatomical priors across multiple spatial resolutions through a segmentation mask pyramid and introduces a scale-specific loss function to guide learning at each level. When evaluated on the SynthRAD2023 brain dataset, our model achieves a mean absolute error (MAE) of 61.82 HU, a peak signal-to-noise ratio (PSNR) of 32.05 dB, and a structural similarity index (SSIM) of 0.90, outperforming baseline models. These results suggest that multiscale anatomical guidance can improve the fidelity and anatomical consistency of sCT images, thus facilitating high-quality CBCT-to-CT translation in radiotherapy applications.
- Open Access
- 25 November 2025
- Published by MDPI AG in Bioengineering
- Vol. 12  (12) , 1297
Deep Learning for CT Synthesis in Radiotherapy
With the rapid development of artificial intelligence (AI), various deep learning (DL) methods have been introduced into radiation oncology. Among them, the generation of synthetic Computed Tomography (sCT) images has attracted increasing attention, as it supports different clinical scenarios, from image-guided adaptive radiotherapy (IGART) to the simulation-free workflow. This review provides a comprehensive overview of recent studies on DL-based sCT synthesis in radiotherapy from multiple imaging modalities, including Cone-Beam CT (CBCT), Magnetic Resonance Imaging (MRI), and diagnostic CT, and discusses their clinical applications in CBCT-based online adaptive radiotherapy, MRI-guided radiotherapy, and simulation-free workflows. We also examine the architectures of representative DL models such as convolutional neural networks (CNNs) and generative adversarial networks (GANs) and summarize emerging training strategies. Finally, we discuss current challenges of clinical translation of DL algorithms into clinical practice and suggest potential directions for future research. Overall, this paper highlights the potential of AI-driven sCT generation to advance treatment planning by reducing imaging burden, improving dose accuracy, and accelerating workflow efficiency, thus ultimately improving the treatment outcome of patient care.
- 25 November 2025
- Published by MDPI AG in Bioengineering
- Vol. 12  (12) , 1297
Open AccessDeep Learning for CT Synthesis in Radiotherapy
With the rapid development of artificial intelligence (AI), various deep learning (DL) methods have been introduced into radiation oncology. Among them, the generation of synthetic Computed Tomography (sCT) images has attracted increasing attention, as it supports different clinical scenarios, from image-guided adaptive radiotherapy (IGART) to the simulation-free workflow. This review provides a comprehensive overview of recent studies on DL-based sCT synthesis in radiotherapy from multiple imaging modalities, including Cone-Beam CT (CBCT), Magnetic Resonance Imaging (MRI), and diagnostic CT, and discusses their clinical applications in CBCT-based online adaptive radiotherapy, MRI-guided radiotherapy, and simulation-free workflows. We also examine the architectures of representative DL models such as convolutional neural networks (CNNs) and generative adversarial networks (GANs) and summarize emerging training strategies. Finally, we discuss current challenges of clinical translation of DL algorithms into clinical practice and suggest potential directions for future research. Overall, this paper highlights the potential of AI-driven sCT generation to advance treatment planning by reducing imaging burden, improving dose accuracy, and accelerating workflow efficiency, thus ultimately improving the treatment outcome of patient care.
- Open Access
Multimodal Slice Interaction Network Enhanced by Transfer Learning for Precise Segmentation of Internal Gross Tumor Volume in Lung Cancer PET/CT Imaging
Lung cancer remains the leading cause of cancerrelated deaths globally. Accurate delineation of internal gross tumor volume (IGTV) in PET/CT imaging is pivotal for optimal radiation therapy in mobile tumors such as lung cancer to account for tumor motion, yet is hindered by the limited availability of annotated IGTV datasets and attenuated PET signal intensity at tumor boundaries. In this study, we present a transfer learningbased methodology utilizing a multimodal interactive perception network with MAMBA, pre-trained on extensive gross tumor volume (GTV) datasets and subsequently fine-tuned on a private IGTV cohort. This cohort constitutes the PET/CT subset of the Lung-cancer Unified Cross-modal Imaging Dataset (LUCID). To further address the challenge of weak PET intensities in IGTV peripheral slices, we introduce a slice interaction module (SIM) within a 2.5D segmentation framework to effectively model inter-slice relationships. Our proposed module integrates channel and spatial attention branches with depthwise convolutions, enabling more robust learning of slice-to-slice dependencies and thereby improving overall segmentation performance. A comprehensive experimental evaluation demonstrates that our approach achieves a Dice of 0.609 on the private IGTV dataset, substantially surpassing the conventional baseline score of 0.385. This work highlights the potential of transfer learning, coupled with advanced multimodal techniques and a SIM to enhance the reliability and clinical relevance of IGTV segmentation for lung cancer radiation therapy planning.
Open AccessMultimodal Slice Interaction Network Enhanced by Transfer Learning for Precise Segmentation of Internal Gross Tumor Volume in Lung Cancer PET/CT Imaging
Lung cancer remains the leading cause of cancerrelated deaths globally. Accurate delineation of internal gross tumor volume (IGTV) in PET/CT imaging is pivotal for optimal radiation therapy in mobile tumors such as lung cancer to account for tumor motion, yet is hindered by the limited availability of annotated IGTV datasets and attenuated PET signal intensity at tumor boundaries. In this study, we present a transfer learningbased methodology utilizing a multimodal interactive perception network with MAMBA, pre-trained on extensive gross tumor volume (GTV) datasets and subsequently fine-tuned on a private IGTV cohort. This cohort constitutes the PET/CT subset of the Lung-cancer Unified Cross-modal Imaging Dataset (LUCID). To further address the challenge of weak PET intensities in IGTV peripheral slices, we introduce a slice interaction module (SIM) within a 2.5D segmentation framework to effectively model inter-slice relationships. Our proposed module integrates channel and spatial attention branches with depthwise convolutions, enabling more robust learning of slice-to-slice dependencies and thereby improving overall segmentation performance. A comprehensive experimental evaluation demonstrates that our approach achieves a Dice of 0.609 on the private IGTV dataset, substantially surpassing the conventional baseline score of 0.385. This work highlights the potential of transfer learning, coupled with advanced multimodal techniques and a SIM to enhance the reliability and clinical relevance of IGTV segmentation for lung cancer radiation therapy planning.
- Open Access
- 31 July 2025
- Published by MDPI AG in Bioengineering
- Vol. 12  (8) , 835
A Language Vision Model Approach for Automated Tumor Contouring in Radiation Oncology
Background: Lung cancer ranks as the leading cause of cancer-related mortality worldwide. The complexity of tumor delineation, crucial for radiation therapy, requires expertise often unavailable in resource-limited settings. Artificial Intelligence (AI), particularly with advancements in deep learning (DL) and natural language processing (NLP), offers potential solutions yet is challenged by high false positive rates. Purpose: The Oncology Contouring Copilot (OCC) system is developed to leverage oncologist expertise for precise tumor contouring using textual descriptions, aiming to increase the efficiency of oncological workflows by combining the strengths of AI with human oversight. Methods: Our OCC system initially identifies nodule candidates from CT scans. Employing Language Vision Models (LVMs) like GPT-4V, OCC then effectively reduces false positives with clinical descriptive texts, merging textual and visual data to automate tumor delineation, designed to elevate the quality of oncology care by incorporating knowledge from experienced domain experts. Results: The deployment of the OCC system resulted in a 35.0% reduction in the false discovery rate, a 72.4% decrease in false positives per scan, and an F1-score of 0.652 across our dataset for unbiased evaluation. Conclusions: OCC represents a significant advance in oncology care, particularly through the use of the latest LVMs, improving contouring results by (1) streamlining oncology treatment workflows by optimizing tumor delineation and reducing manual processes; (2) offering a scalable and intuitive framework to reduce false positives in radiotherapy planning using LVMs; (3) introducing novel medical language vision prompt techniques to minimize LVM hallucinations with ablation study; and (4) conducting a comparative analysis of LVMs, highlighting their potential in addressing medical language vision challenges.
- 31 July 2025
- Published by MDPI AG in Bioengineering
- Vol. 12  (8) , 835
Open AccessA Language Vision Model Approach for Automated Tumor Contouring in Radiation Oncology
Background: Lung cancer ranks as the leading cause of cancer-related mortality worldwide. The complexity of tumor delineation, crucial for radiation therapy, requires expertise often unavailable in resource-limited settings. Artificial Intelligence (AI), particularly with advancements in deep learning (DL) and natural language processing (NLP), offers potential solutions yet is challenged by high false positive rates. Purpose: The Oncology Contouring Copilot (OCC) system is developed to leverage oncologist expertise for precise tumor contouring using textual descriptions, aiming to increase the efficiency of oncological workflows by combining the strengths of AI with human oversight. Methods: Our OCC system initially identifies nodule candidates from CT scans. Employing Language Vision Models (LVMs) like GPT-4V, OCC then effectively reduces false positives with clinical descriptive texts, merging textual and visual data to automate tumor delineation, designed to elevate the quality of oncology care by incorporating knowledge from experienced domain experts. Results: The deployment of the OCC system resulted in a 35.0% reduction in the false discovery rate, a 72.4% decrease in false positives per scan, and an F1-score of 0.652 across our dataset for unbiased evaluation. Conclusions: OCC represents a significant advance in oncology care, particularly through the use of the latest LVMs, improving contouring results by (1) streamlining oncology treatment workflows by optimizing tumor delineation and reducing manual processes; (2) offering a scalable and intuitive framework to reduce false positives in radiotherapy planning using LVMs; (3) introducing novel medical language vision prompt techniques to minimize LVM hallucinations with ablation study; and (4) conducting a comparative analysis of LVMs, highlighting their potential in addressing medical language vision challenges.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43  (9) , 3176-3187
XIOSIS: An X-Ray-Based Intra-Operative Image-Guided Platform for Oncology Smart Material Delivery
Image-guided interventional oncology procedures can greatly enhance the outcome of cancer treatment. As an enhancing procedure, oncology smart material delivery can increase cancer therapy’s quality, effectiveness, and safety. However, the effectiveness of enhancing procedures highly depends on the accuracy of smart material placement procedures. Inaccurate placement of smart materials can lead to adverse side effects and health hazards. Image guidance can considerably improve the safety and robustness of smart material delivery. In this study, we developed a novel generative deep-learning platform that highly prioritizes clinical practicality and provides the most informative intra-operative feedback for image-guided smart material delivery. XIOSIS generates a patient-specific 3D volumetric computed tomography (CT) from three intraoperative radiographs (X-ray images) acquired by a mobile C-arm during the operation. As the first of its kind, XIOSIS (i) synthesizes the CT from small field-of-view radiographs;(ii) reconstructs the intra-operative spacer distribution; (iii) is robust; and (iv) is equipped with a novel soft-contrast cost function. To demonstrate the effectiveness of XIOSIS in providing intra-operative image guidance, we applied XIOSIS to the duodenal hydrogel spacer placement procedure. We evaluated XIOSIS performance in an image-guided virtual spacer placement and actual spacer placement in two cadaver specimens. XIOSIS showed a clinically acceptable performance, reconstructed the 3D intra-operative hydrogel spacer distribution with an average structural similarity of 0.88 and Dice coefficient of 0.63 and with less than 1 cm difference in spacer location relative to the spinal cord.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43  (9) , 3176-3187
XIOSIS: An X-Ray-Based Intra-Operative Image-Guided Platform for Oncology Smart Material Delivery
Image-guided interventional oncology procedures can greatly enhance the outcome of cancer treatment. As an enhancing procedure, oncology smart material delivery can increase cancer therapy’s quality, effectiveness, and safety. However, the effectiveness of enhancing procedures highly depends on the accuracy of smart material placement procedures. Inaccurate placement of smart materials can lead to adverse side effects and health hazards. Image guidance can considerably improve the safety and robustness of smart material delivery. In this study, we developed a novel generative deep-learning platform that highly prioritizes clinical practicality and provides the most informative intra-operative feedback for image-guided smart material delivery. XIOSIS generates a patient-specific 3D volumetric computed tomography (CT) from three intraoperative radiographs (X-ray images) acquired by a mobile C-arm during the operation. As the first of its kind, XIOSIS (i) synthesizes the CT from small field-of-view radiographs;(ii) reconstructs the intra-operative spacer distribution; (iii) is robust; and (iv) is equipped with a novel soft-contrast cost function. To demonstrate the effectiveness of XIOSIS in providing intra-operative image guidance, we applied XIOSIS to the duodenal hydrogel spacer placement procedure. We evaluated XIOSIS performance in an image-guided virtual spacer placement and actual spacer placement in two cadaver specimens. XIOSIS showed a clinically acceptable performance, reconstructed the 3D intra-operative hydrogel spacer distribution with an average structural similarity of 0.88 and Dice coefficient of 0.63 and with less than 1 cm difference in spacer location relative to the spinal cord.
- Open Access
Enhancing Image-Guided Radiation Therapy for Pancreatic Cancer: Utilizing Aligned Peak Response Beamforming in Flexible Array Transducers
To develop ultrasound-guided radiotherapy, we proposed an assistant structure with embedded markers along with a novel alternative method, the Aligned Peak Response (APR) method, to alter the conventional delay-and-sum (DAS) beamformer for reconstructing ultrasound images obtained from a flexible array. We simulated imaging targets in Field-II using point target phantoms with point targets at different locations. In the experimental phantom ultrasound images, image RF data were acquired with a flexible transducer with in-house assistant structures embedded with needle targets for testing the accuracy of the APR method. The lateral full width at half maximum (FWHM) values of the objective point target (OPT) in ground truth ultrasound images, APR-delayed ultrasound images with a flat shape, and images acquired with curved transducer radii of 500 mm and 700 mm were 3.96 mm, 4.95 mm, 4.96 mm, and 4.95 mm. The corresponding axial FWHM values were 1.52 mm, 4.08 mm, 5.84 mm, and 5.92 mm, respectively. These results demonstrate that the proposed assistant structure and the APR method have the potential to construct accurate delay curves without external shape sensing, thereby enabling a flexible ultrasound array for tracking pancreatic tumor targets in real time for radiotherapy.
Open AccessEnhancing Image-Guided Radiation Therapy for Pancreatic Cancer: Utilizing Aligned Peak Response Beamforming in Flexible Array Transducers
To develop ultrasound-guided radiotherapy, we proposed an assistant structure with embedded markers along with a novel alternative method, the Aligned Peak Response (APR) method, to alter the conventional delay-and-sum (DAS) beamformer for reconstructing ultrasound images obtained from a flexible array. We simulated imaging targets in Field-II using point target phantoms with point targets at different locations. In the experimental phantom ultrasound images, image RF data were acquired with a flexible transducer with in-house assistant structures embedded with needle targets for testing the accuracy of the APR method. The lateral full width at half maximum (FWHM) values of the objective point target (OPT) in ground truth ultrasound images, APR-delayed ultrasound images with a flat shape, and images acquired with curved transducer radii of 500 mm and 700 mm were 3.96 mm, 4.95 mm, 4.96 mm, and 4.95 mm. The corresponding axial FWHM values were 1.52 mm, 4.08 mm, 5.84 mm, and 5.92 mm, respectively. These results demonstrate that the proposed assistant structure and the APR method have the potential to construct accurate delay curves without external shape sensing, thereby enabling a flexible ultrasound array for tracking pancreatic tumor targets in real time for radiotherapy.
- Open Access
Investigating the Use of a Liquid Immunogenic Fiducial Eluter Biomaterial in Cervical Cancer Treatment
Globally, cervical cancer is the fourth leading cancer among women and is dominant in resource-poor settings in its occurrence and mortality. This study focuses on developing liquid immunogenic fiducial eluter (LIFE) Biomaterial with components that include biodegradable polymers, nanoparticles, and an immunoadjuvant. LIFE Biomaterial is designed to provide image guidance during radiotherapy similar to clinically used liquid fiducials while enhancing therapeutic efficacy for advanced cervical cancer. C57BL6 mice were used to grow subcutaneous tumors on bilateral flanks. The tumor on one flank was then treated using LIFE Biomaterial prepared with the immunoadjuvant anti-CD40, with/without radiotherapy at 6 Gy. Computed tomography (CT) and magnetic resonance (MR) imaging visibility were also evaluated in human cadavers. A pharmacodynamics study was also conducted to assess the safety of LIFE Biomaterial in healthy C57BL6 female mice. Results showed that LIFE Biomaterial could provide both CT and MR imaging contrast over time. Inhibition in tumor growth and prolonged significant survival (* p < 0.05) were consistently observed for groups treated with the combination of radiotherapy and LIFE Biomaterial, highlighting the potential for this strategy. Minimal toxicity was observed for healthy mice treated with LIFE Biomaterial with/without anti-CD40 in comparison to non-treated cohorts. The results demonstrate promise for the further development and clinical translation of this approach to enhance the survival and quality of life of patients with advanced cervical cancer.
Open AccessInvestigating the Use of a Liquid Immunogenic Fiducial Eluter Biomaterial in Cervical Cancer Treatment
Globally, cervical cancer is the fourth leading cancer among women and is dominant in resource-poor settings in its occurrence and mortality. This study focuses on developing liquid immunogenic fiducial eluter (LIFE) Biomaterial with components that include biodegradable polymers, nanoparticles, and an immunoadjuvant. LIFE Biomaterial is designed to provide image guidance during radiotherapy similar to clinically used liquid fiducials while enhancing therapeutic efficacy for advanced cervical cancer. C57BL6 mice were used to grow subcutaneous tumors on bilateral flanks. The tumor on one flank was then treated using LIFE Biomaterial prepared with the immunoadjuvant anti-CD40, with/without radiotherapy at 6 Gy. Computed tomography (CT) and magnetic resonance (MR) imaging visibility were also evaluated in human cadavers. A pharmacodynamics study was also conducted to assess the safety of LIFE Biomaterial in healthy C57BL6 female mice. Results showed that LIFE Biomaterial could provide both CT and MR imaging contrast over time. Inhibition in tumor growth and prolonged significant survival (* p < 0.05) were consistently observed for groups treated with the combination of radiotherapy and LIFE Biomaterial, highlighting the potential for this strategy. Minimal toxicity was observed for healthy mice treated with LIFE Biomaterial with/without anti-CD40 in comparison to non-treated cohorts. The results demonstrate promise for the further development and clinical translation of this approach to enhance the survival and quality of life of patients with advanced cervical cancer.
- Open Access
Enhancement of Stopping Power Ratio (SPR) Estimation Accuracy through Image-Domain Dual-Energy Computer Tomography for Pencil Beam Scanning System: A Simulation Study
Our study aims to quantify the impact of spectral separation on achieved theoretical prediction accuracy of proton-stopping power when the volume discrepancy between calibration phantom and scanned object is observed. Such discrepancy can be commonly seen in our CSI pediatric patients. One of the representative image-domain DECT models is employed on a virtual phantom to derive electron density and effective atomic number for a total of 34 ICRU standard human tissues. The spectral pairs used in this study are 90 kVp/140 kVp, without and with 0.1 mm to 0.5 mm additional tin filter. The two DECT images are reconstructed via a conventional filtered back projection algorithm (FBP) on simulated noiseless projection data. The best-predicted accuracy occurs at a spectral pair of 90 kVp/140 kVp with a 0.3 mm tin filter, and the root-mean-squared average error is 0.12% for tissue substitutes. The results reveal that the selected image-domain model is sensitive to spectral pair deviation when there is a discrepancy between calibration and scanning conditions. This study suggests that an optimization process may be needed for clinically available DECT scanners to yield the best proton-stopping power estimation.
Open AccessEnhancement of Stopping Power Ratio (SPR) Estimation Accuracy through Image-Domain Dual-Energy Computer Tomography for Pencil Beam Scanning System: A Simulation Study
Our study aims to quantify the impact of spectral separation on achieved theoretical prediction accuracy of proton-stopping power when the volume discrepancy between calibration phantom and scanned object is observed. Such discrepancy can be commonly seen in our CSI pediatric patients. One of the representative image-domain DECT models is employed on a virtual phantom to derive electron density and effective atomic number for a total of 34 ICRU standard human tissues. The spectral pairs used in this study are 90 kVp/140 kVp, without and with 0.1 mm to 0.5 mm additional tin filter. The two DECT images are reconstructed via a conventional filtered back projection algorithm (FBP) on simulated noiseless projection data. The best-predicted accuracy occurs at a spectral pair of 90 kVp/140 kVp with a 0.3 mm tin filter, and the root-mean-squared average error is 0.12% for tissue substitutes. The results reveal that the selected image-domain model is sensitive to spectral pair deviation when there is a discrepancy between calibration and scanning conditions. This study suggests that an optimization process may be needed for clinically available DECT scanners to yield the best proton-stopping power estimation.