Abstract
An enzyme based biosensor was developed for the detection of glucose in blood plasma. The electrode was fabricated by immobilizing glucose oxidase (GOx) along with graphene oxide (GO) on Prussian blue (PB) modified platinum (Pt) electrode using nafion as a binder. The GO modification on Pt/PB electrode increases the voltammetric response current towards the reduction of H2O2 compared to Pt/PB electrode. The modified electrode showed a linear amperometric response at an applied potential of −0.1 V towards the detection of glucose from 2 μM to 20 μM with a detection limit of 1.35 μM and its sensitivity was found to be 175 × 10−2 A M−1 cm−2. As the low applied potential avoids the interferences due to urea, uric acid and ascorbic acid, the amperometric response of the modified electrode was found to be negligible both in the presence and absence of glucose. The response time for 95% of the response current was found to be 5 s. The developed electrode shows excellent stability over a period of two weeks with only a 13.6% decrease from the initial amperometric response and an appreciable repeatability with relative standard deviation (RSD) of 4.43% (n = 6).Keywords
This publication has 27 references indexed in Scilit:
- Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructuresBiosensors and Bioelectronics, 2004
- Metal Hexacyanoferrates: Electrosynthesis, in Situ Characterization, and ApplicationsChemistry of Materials, 2003
- Prussian Blue and Its Analogues: Electrochemistry and Analytical ApplicationsElectroanalysis, 2001
- Prussian Blue-based `artificial peroxidase' as a transducer for hydrogen peroxide detection. Application to biosensorsSensors and Actuators B: Chemical, 1999
- On the mechanism of H2O2 reduction at Prussian Blue modified electrodesElectrochemistry Communications, 1999
- Electrochemical characteristics of two model electropolymerised films for enzyme electrodesBiosensors and Bioelectronics, 1996
- Improvement of Electrochemical Biosensors Using Enzyme Immobilization from Water−Organic Mixtures with a High Content of Organic SolventAnalytical Chemistry, 1996
- Sensing with chemically and biologically modified carbon electrodes. A reviewThe Analyst, 1995
- A High-Sensitive Glucose Amperometric Biosensor Based on Prussian Blue Modified ElectrodesAnalytical Letters, 1994
- Modification of electrode surfaces with oxidised phenols to confer selectivity to amperometric biosensors for glucose determinationAnalytica Chimica Acta, 1993