Valsala Madhavan Nair Biju
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Valsala Madhavan Nair Biju has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Allibai Mohanan Vinu Mohan
Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, Tamil Nadu 630003, India
3 shared publications - K.K. Aswini
Department of Chemistry, National Institute of Technology, Tiruchirappalli, TamilNadu 620 015, India
2 shared publications - Sambhani Naga Gayatri
Chemistry Division Department of H&S CVR College of Engineering Hyderabad, Telangana 501510 India
2 shared publications - A. Maria Starvin
Department of Chemistry, Christian College, Kattakada, Thiruvananthapuram, Kerala, India
1 shared publication Ambrose Maria Starvin
Department of Chemistry, Christian College, Thiruvananthapuram, Kerala, India
1 shared publicationAmmanamanchi Radhakrishna
Analytical Science Division, Shriram Institute for Industrial Research, Bangalore, Karnataka 560 048 India
1 shared publication
Latest Publications
- 27 November 2018
- Published by Springer Nature in Journal of Fluorescence
- Vol. 29 (1) , 203-209
Determination of Ondansetron by Spectrofluorimetry: Application to Forced Degradation Study, Pharmaceuticals and Human Plasma
The current manuscript describes a validated, responsive and rapid spectrofluorimetric method for quantifying ondansetron (OND) in authentic form, spiked human plasma and dosage forms. This is the first reported fluorescence study of Ondansetron in Triton X 100 system. Various variables affecting fluorescence response were studied precisely and optimised. The described method involved the fluorescence measurement in Triton X 100 system at λem/λex 354/317 nm. The calibration plot attained linearity over concentration range of 0.2 – 2 μg/mL. The developed method has been extensively applied to degradation studies of OND as per International Conference on Harmonisation (ICH) guidelines by exposing to oxidative, thermal, photo, acidic and alkaline conditions and also the degradation pathway has been proposed.
- 27 November 2018
- Published by Springer Nature in Journal of Fluorescence
- Vol. 29 (1) , 203-209
Determination of Ondansetron by Spectrofluorimetry: Application to Forced Degradation Study, Pharmaceuticals and Human Plasma
The current manuscript describes a validated, responsive and rapid spectrofluorimetric method for quantifying ondansetron (OND) in authentic form, spiked human plasma and dosage forms. This is the first reported fluorescence study of Ondansetron in Triton X 100 system. Various variables affecting fluorescence response were studied precisely and optimised. The described method involved the fluorescence measurement in Triton X 100 system at λem/λex 354/317 nm. The calibration plot attained linearity over concentration range of 0.2 – 2 μg/mL. The developed method has been extensively applied to degradation studies of OND as per International Conference on Harmonisation (ICH) guidelines by exposing to oxidative, thermal, photo, acidic and alkaline conditions and also the degradation pathway has been proposed.
- 4 July 2018
- Published by Springer Nature in Journal of Fluorescence
- Vol. 28 (4) , 951-957
A Micelle-Enhanced Spectrofluorimetric Determination of Pirfenidone: Application to Content Uniformity Testing and Human Urine
The present manuscript gives a detailed account of highly selective, validated and sensitive method for quantification of pirfenidone in its pharmaceutical dosage forms and spiked human urine. The developed method is relied on the systematic study of the fluorescence action of Pirfenidone in Tween – 80 micellar medium. The Pirfenidone exhibits strong fluorescence at λem 396 nm upon excitation at λex 318 nm in Tween −80 medium. The fluorescence - concentration plot was linear over concentration range of 0.5 – 5 μg/mL. There was greater extent (1.02 fold) of enhancement in fluorescence intensity in presence of tween – 80 with very low limit of detection and quantitation of 0.04 μg/mL and 0.11 μg/mL respectively. The application of developed methodology is successfully applied to content uniformity testing and spiked human urine. The proposed study was successfully applied for analysis of pirfenidone in commercially available pharmaceutical formulations.
- 4 July 2018
- Published by Springer Nature in Journal of Fluorescence
- Vol. 28 (4) , 951-957
A Micelle-Enhanced Spectrofluorimetric Determination of Pirfenidone: Application to Content Uniformity Testing and Human Urine
The present manuscript gives a detailed account of highly selective, validated and sensitive method for quantification of pirfenidone in its pharmaceutical dosage forms and spiked human urine. The developed method is relied on the systematic study of the fluorescence action of Pirfenidone in Tween – 80 micellar medium. The Pirfenidone exhibits strong fluorescence at λem 396 nm upon excitation at λex 318 nm in Tween −80 medium. The fluorescence - concentration plot was linear over concentration range of 0.5 – 5 μg/mL. There was greater extent (1.02 fold) of enhancement in fluorescence intensity in presence of tween – 80 with very low limit of detection and quantitation of 0.04 μg/mL and 0.11 μg/mL respectively. The application of developed methodology is successfully applied to content uniformity testing and spiked human urine. The proposed study was successfully applied for analysis of pirfenidone in commercially available pharmaceutical formulations.
- 8 June 2017
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (16) , 2540-2546
Room temperature ionic liquid, cetyl pyridinium naphthenate, supported cloud point extractive separation and ultra trace determination of copper in blood and environmental samples
A new unconventional room temperature ionic liquid, cetyl pyridinium naphthenate (CPN) was synthesized and was ascertained by IR, NMR and CHN analysis. Cloud point extraction of Cu(II) was carried out by using CPN for a synergistic enhancement effect. Triton X 100 was used as surfactant in cloud point extraction and cloud point temperature was 750 C. Quantification was carried out by FAAS. The mean recovery, enrichment factor, tolerance limit, RSD, LOD and LOQ were found to be 99.8%, 40, 1000 ppm, 0.15%, 27 ppt and 93 ppt respectively. Method was validated by analyzing natural water and blood samples.
- 8 June 2017
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (16) , 2540-2546
Room temperature ionic liquid, cetyl pyridinium naphthenate, supported cloud point extractive separation and ultra trace determination of copper in blood and environmental samples
A new unconventional room temperature ionic liquid, cetyl pyridinium naphthenate (CPN) was synthesized and was ascertained by IR, NMR and CHN analysis. Cloud point extraction of Cu(II) was carried out by using CPN for a synergistic enhancement effect. Triton X 100 was used as surfactant in cloud point extraction and cloud point temperature was 750 C. Quantification was carried out by FAAS. The mean recovery, enrichment factor, tolerance limit, RSD, LOD and LOQ were found to be 99.8%, 40, 1000 ppm, 0.15%, 27 ppt and 93 ppt respectively. Method was validated by analyzing natural water and blood samples.
- 1 April 2014
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 37, 321-326
Molecularly imprinted polymer based electrochemical detection of L-cysteine at carbon paste electrode
- 1 April 2014
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 37, 321-326
Molecularly imprinted polymer based electrochemical detection of L-cysteine at carbon paste electrode
- 1 December 2013
- Published by Springer Nature in Journal of Food Science and Technology
- Vol. 51 (4) , 805-812
Quantitative determination of melatonin in milk by LC-MS/MS
A rapid, reliable and sensitive LC-MS/MS method for the determination of melatonin in milk was developed and validated. Sample was extracted with dichloromethane and cleaned by passing through Chem Elut solid phase extraction cartridge. The solvent was evaporated to dryness, reconstituted with methanol and analysed by LC-MS/MS on Agilent zorbax Eclipse XDB C-18 rapid resolution analytical column. The analytical procedure was found to be accurate, precise and linear. The method accuracy was 92.2 % (range 90.06–94.58) and the mean precision was 1.55 % and the calibration was linear for 1 to 150 pg mL−1 (R2 > 0.99), the lowest limit of quantification (LLOQ) was 1 pg mL−1. 7-D Melatonin (7-DM) was used as an internal standard. This method was proved to be a promising method for the determination of melatonin for market milk and human milk samples.
- 1 December 2013
- Published by Springer Nature in Journal of Food Science and Technology
- Vol. 51 (4) , 805-812
Quantitative determination of melatonin in milk by LC-MS/MS
A rapid, reliable and sensitive LC-MS/MS method for the determination of melatonin in milk was developed and validated. Sample was extracted with dichloromethane and cleaned by passing through Chem Elut solid phase extraction cartridge. The solvent was evaporated to dryness, reconstituted with methanol and analysed by LC-MS/MS on Agilent zorbax Eclipse XDB C-18 rapid resolution analytical column. The analytical procedure was found to be accurate, precise and linear. The method accuracy was 92.2 % (range 90.06–94.58) and the mean precision was 1.55 % and the calibration was linear for 1 to 150 pg mL−1 (R2 > 0.99), the lowest limit of quantification (LLOQ) was 1 pg mL−1. 7-D Melatonin (7-DM) was used as an internal standard. This method was proved to be a promising method for the determination of melatonin for market milk and human milk samples.
- 14 January 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (7) , 1764-1770
Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
An enzyme based biosensor was developed for the detection of glucose in blood plasma. The electrode was fabricated by immobilizing glucose oxidase (GOx) along with graphene oxide (GO) on Prussian blue (PB) modified platinum (Pt) electrode using nafion as a binder. The GO modification on Pt/PB electrode increases the voltammetric response current towards the reduction of H2O2 compared to Pt/PB electrode. The modified electrode showed a linear amperometric response at an applied potential of −0.1 V towards the detection of glucose from 2 μM to 20 μM with a detection limit of 1.35 μM and its sensitivity was found to be 175 × 10−2 A M−1 cm−2. As the low applied potential avoids the interferences due to urea, uric acid and ascorbic acid, the amperometric response of the modified electrode was found to be negligible both in the presence and absence of glucose. The response time for 95% of the response current was found to be 5 s. The developed electrode shows excellent stability over a period of two weeks with only a 13.6% decrease from the initial amperometric response and an appreciable repeatability with relative standard deviation (RSD) of 4.43% (n = 6).
- 14 January 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (7) , 1764-1770
Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
An enzyme based biosensor was developed for the detection of glucose in blood plasma. The electrode was fabricated by immobilizing glucose oxidase (GOx) along with graphene oxide (GO) on Prussian blue (PB) modified platinum (Pt) electrode using nafion as a binder. The GO modification on Pt/PB electrode increases the voltammetric response current towards the reduction of H2O2 compared to Pt/PB electrode. The modified electrode showed a linear amperometric response at an applied potential of −0.1 V towards the detection of glucose from 2 μM to 20 μM with a detection limit of 1.35 μM and its sensitivity was found to be 175 × 10−2 A M−1 cm−2. As the low applied potential avoids the interferences due to urea, uric acid and ascorbic acid, the amperometric response of the modified electrode was found to be negligible both in the presence and absence of glucose. The response time for 95% of the response current was found to be 5 s. The developed electrode shows excellent stability over a period of two weeks with only a 13.6% decrease from the initial amperometric response and an appreciable repeatability with relative standard deviation (RSD) of 4.43% (n = 6).