Denis Raccah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Denis Raccah has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Bruno Guerci
Centre Hospitalier Universitaire de Nancy and University of Nancy, Nancy, France
1 shared publicationEric Renard
Centre Hospitalier Universitaire de Montpellier and University of Montpellier, Montpellier, France
1 shared publicationHélène Hanaire
Centre Hospitalier Universitaire de Toulouse and University of Toulouse, Toulouse, France
1 shared publicationMarc Nicolino
Hospital Femme-Mère-Enfant, Lyon, France
1 shared publicationNathalie Jeandidier
University Louis Pasteur Hospital, Strasbourg, France
1 shared publicationVéronique Sulmont
American Memorial Hospital, Children's Hospital, Reims, France
1 shared publication
Latest Publications
- Open Access
- 18 September 2009
- Published by American Diabetes Association in Diabetes Care
- Vol. 32 (12) , 2245-2250
Incremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 Diabetes
OBJECTIVE To compare the improvements in glycemic control associated with transitioning to insulin pump therapy in patients using continuous glucose monitoring versus standard blood glucose self-monitoring. RESEARCH DESIGN AND METHODS The RealTrend study was a 6-month, randomized, parallel-group, two-arm, open-label study of 132 adults and children with uncontrolled type 1 diabetes (A1C ≥8%) being treated with multiple daily injections. One group was fitted with the Medtronic MiniMed Paradigm REAL-Time system (PRT group), an insulin pump with integrated continuous subcutaneous glucose monitoring (CGM) capability, with instructions to wear CGM sensors at least 70% of the time. Conventional insulin pump therapy was initiated in the other group (continuous subcutaneous insulin infusion [CSII] group). Outcome measures included A1C and glycemic variability. RESULTS A total of 115 patients completed the study. Between baseline and trial end, A1C improved significantly in both groups (PRT group −0.81 ± 1.09%, P < 0.001; CSII group −0.57 ± 0.94%, P < 0.001), with no significant difference between groups. When the 91 patients who were fully protocol-compliant (including CGM sensor wear ≥70% of the time) were considered, A1C improvement was significantly greater in the PRT group (P = 0.004) (PRT group −0.96 ± 0.93%, P < 0.001; CSII group −0.55 ± 0.93%, P < 0.001). Hyperglycemia parameters decreased in line with improvements in A1C with no impact on hypoglycemia. CONCLUSIONS CGM-enabled insulin pump therapy improves glycemia more than conventional pump therapy during the first 6 months of pump use in patients who wear CGM sensors at least 70% of the time.
- 18 September 2009
- Published by American Diabetes Association in Diabetes Care
- Vol. 32 (12) , 2245-2250
Open AccessIncremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 Diabetes
OBJECTIVE To compare the improvements in glycemic control associated with transitioning to insulin pump therapy in patients using continuous glucose monitoring versus standard blood glucose self-monitoring. RESEARCH DESIGN AND METHODS The RealTrend study was a 6-month, randomized, parallel-group, two-arm, open-label study of 132 adults and children with uncontrolled type 1 diabetes (A1C ≥8%) being treated with multiple daily injections. One group was fitted with the Medtronic MiniMed Paradigm REAL-Time system (PRT group), an insulin pump with integrated continuous subcutaneous glucose monitoring (CGM) capability, with instructions to wear CGM sensors at least 70% of the time. Conventional insulin pump therapy was initiated in the other group (continuous subcutaneous insulin infusion [CSII] group). Outcome measures included A1C and glycemic variability. RESULTS A total of 115 patients completed the study. Between baseline and trial end, A1C improved significantly in both groups (PRT group −0.81 ± 1.09%, P < 0.001; CSII group −0.57 ± 0.94%, P < 0.001), with no significant difference between groups. When the 91 patients who were fully protocol-compliant (including CGM sensor wear ≥70% of the time) were considered, A1C improvement was significantly greater in the PRT group (P = 0.004) (PRT group −0.96 ± 0.93%, P < 0.001; CSII group −0.55 ± 0.93%, P < 0.001). Hyperglycemia parameters decreased in line with improvements in A1C with no impact on hypoglycemia. CONCLUSIONS CGM-enabled insulin pump therapy improves glycemia more than conventional pump therapy during the first 6 months of pump use in patients who wear CGM sensors at least 70% of the time.
- 10 June 2008
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 10 (s2) , 76-82
Options for the intensification of insulin therapy when basal insulin is not enough in type 2 diabetes mellitus
In the early treatment of type 2 diabetes mellitus (T2DM), the addition of a basal insulin, such as insulin glargine, to existing oral therapy can help patients attain recommended glycaemic control targets, including haemoglobin A 1c (HbA 1c ) 1c remains above target and to manage postprandial glucose excursions at other meals. Prospective studies are underway to further examine this concept and determine the benefit of this approach not only on overall glycaemic control but also on cardiovascular risk.
- 10 June 2008
- Published by Wiley in Diabetes, Obesity and Metabolism
- Vol. 10 (s2) , 76-82
Options for the intensification of insulin therapy when basal insulin is not enough in type 2 diabetes mellitus
In the early treatment of type 2 diabetes mellitus (T2DM), the addition of a basal insulin, such as insulin glargine, to existing oral therapy can help patients attain recommended glycaemic control targets, including haemoglobin A 1c (HbA 1c ) 1c remains above target and to manage postprandial glucose excursions at other meals. Prospective studies are underway to further examine this concept and determine the benefit of this approach not only on overall glycaemic control but also on cardiovascular risk.