Constrained optimized water suppression for 1H MR spectroscopy
- 4 June 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (3) , 895-904
Abstract
Purpose: Water suppression is a necessary component to standard MR spectroscopy experiments due to the approximately 5000–10 000‐fold higher water concentration and signal intensity compared with that of the metabolites and macromolecules of interest. Here, a novel algorithm referred to as constrained optimized water suppression (COWS) was developed, which enables generation of effective water suppression modules with an arbitrary number of radiofrequency (RF) pulses, and flexibly accommodates minimum durations between pulses, minimum total module duration, and maximum flip angles.Methods: We use the COWS algorithm to create a water‐suppression module with seven pulses, the same number of RF pulses as typical VAPOR7, at a reduced module duration of 236 ms, referred to as COWS(7;236), as well as one at the typical VAPOR duration but with an increased number of RF pulses, referred to as COWS(12;626). Experimentally, both COWS schemes were compared with variable power radio frequency pulses with optimized relaxation delays (VAPOR) using single‐voxel spectroscopy in the prefrontal cortex, the posterior frontal lobe, and the occipital lobe from data collected from 10 participants on a 3T Siemens MRI scanner.Results: We found that both COWS(7;236) and COWS(12;626) perform similar to VAPOR7 for metabolites, whereas COWS(7;236) had improved performance than VAPOR for macromolecules at a reduced 236‐ms duration.Conclusion: COWS can be used to develop flexible study‐specific water suppression that can perform similarly for metabolite spectra or with improved performance for macromolecule spectra compared with VAPOR7, at a lower module duration.Keywords
This publication has 30 references indexed in Scilit:
- Theoretical description of modern1H in Vivo magnetic resonance spectroscopic pulse sequencesJournal of Magnetic Resonance Imaging, 2019
- Water suppression in the human brain with hypergeometric RF pulses for single‐voxel and multi‐voxel MR spectroscopyMagnetic Resonance in Medicine, 2018
- Metabolite‐cycled STEAM and semi‐LASER localization for MR spectroscopy of the human brain at 9.4TMagnetic Resonance in Medicine, 2017
- Short‐echo, single‐shot, full‐intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: Validation in the cerebellum and brainstemMagnetic Resonance in Medicine, 2010
- Low‐power adiabatic sequences for in vivo localized two‐dimensional chemical shift correlated MR spectroscopyMagnetic Resonance in Medicine, 2010
- Short echo time 1H‐MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulsesMagnetic Resonance in Medicine, 2007
- T1, T2 relaxation and magnetization transfer in tissue at 3TMagnetic Resonance in Medicine, 2005
- New method for the simultaneous detection of metabolites and water in localized in vivo 1H nuclear magnetic resonance spectroscopyMagnetic Resonance in Medicine, 2005
- Adiabatic water suppression using frequency selective excitationMagnetic Resonance in Medicine, 1998
- In vivo proton spectroscopy in presence of eddy currentsMagnetic Resonance in Medicine, 1990