Wrist Pulse Detection System Based on Changes in the Near-Field Reflection Coefficient of a Resonator
Authors:
- 27 August 2014
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 24 (10) , 719-721
Abstract
This letter presents a wrist pulse sensor based on reflection coefficient (S11) from a resonator which is applicable to existing wearable communication devices. The compact resonator is designed on flexible substrate as an RF signal radiator. Since the reflection coefficient from the resonator depends on the distance between the resonator and the wall of the major artery, slight changes in radial artery diameter can be utilized to obtain pulse rate at the wrist. The sensor system is implemented and tested at 2.4 GHz ISM band, and reveals excellent performance in terms of sensitivity as well as convenience as a wearable device compared to conventional piezoelectric or photoplethysmography (PPG) sensor.Keywords
Funding Information
- Ministry of Science, ICT and Future Planning (MSIP), Korea
- Convergence Information Technology Research Center (C-ITRC) support program
- NIPA(National IT Industry Promotion Agency)
This publication has 10 references indexed in Scilit:
- Vital sign detection for handheld communication device using antenna mismatching effect2013
- Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoringNature Communications, 2013
- Wireless RF Sensor Structure for Non-Contact Vital Sign MonitoringJournal of Electromagnetic Engineering and Science, 2012
- Compact Vital Signal Sensor Using Oscillation Frequency DeviationIEEE Transactions on Microwave Theory and Techniques, 2011
- A Wireless Reflectance Pulse Oximeter With Digital Baseline Control for Unfiltered PhotoplethysmogramsIEEE Transactions on Biomedical Circuits and Systems, 2011
- Pulse Transit Time Based on Piezoelectric Technique at the Radial ArteryJournal of Clinical Monitoring and Computing, 2006
- Wrist-located pulse detection using IR signals, activity and nonlinear artifact cancellation2005
- Linear tunable phase shifter using a left-handed transmission lineIEEE Microwave and Wireless Components Letters, 2005
- Clinical measurement of arterial stiffness obtained from noninvasive pressure waveformsAmerican Journal of Hypertension, 2005
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996