Abstract
It is difficult to install the sensor on the end effector of a minimally invasive surgical robot with a narrow space within which to obtain the position and grasping force; thus, the elongation effect of cable-driven surgical instruments results in low precision control, which may damage the tissues and organs of patients. A novel transmission backlash compensation and grasping force saturation limitation algorithm based on the tension and displacement transmission model of a cable-pulley system is proposed to improve the operation’s accuracy and safety. The algorithm considers the force and position transmission characteristics of each stage of the cable-pulley system including the transition stage. Experimental verifications show that the proposed algorithm can significantly improve the position tracking accuracy of surgical instruments and the safety of grasping operations.
Funding Information
  • Director Foundation of Guangxi Key Laboratory of Automatic Detection Technology and Instrument (YQ21110)

This publication has 33 references indexed in Scilit: