Shuizhong Zou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuizhong Zou has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Guozhi Li
School of Artificial Intelligence, Guilin University of Electronic Technology, Guilin 541004, China
1 shared publication - Yuan Huang
School of Electronic Engineering and Automation, Guilin University of Electronic Technology, Guilin 541004, China
1 shared publication
Latest Publications
- Open Access
- 27 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (23) , 12126
Transmission Backlash Compensation and Grasping Force Estimation of Surgical Instruments for the Laparoscopic Minimally Invasive Surgery Robot
It is difficult to install the sensor on the end effector of a minimally invasive surgical robot with a narrow space within which to obtain the position and grasping force; thus, the elongation effect of cable-driven surgical instruments results in low precision control, which may damage the tissues and organs of patients. A novel transmission backlash compensation and grasping force saturation limitation algorithm based on the tension and displacement transmission model of a cable-pulley system is proposed to improve the operation’s accuracy and safety. The algorithm considers the force and position transmission characteristics of each stage of the cable-pulley system including the transition stage. Experimental verifications show that the proposed algorithm can significantly improve the position tracking accuracy of surgical instruments and the safety of grasping operations.
- 27 November 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (23) , 12126
Open AccessTransmission Backlash Compensation and Grasping Force Estimation of Surgical Instruments for the Laparoscopic Minimally Invasive Surgery Robot
It is difficult to install the sensor on the end effector of a minimally invasive surgical robot with a narrow space within which to obtain the position and grasping force; thus, the elongation effect of cable-driven surgical instruments results in low precision control, which may damage the tissues and organs of patients. A novel transmission backlash compensation and grasping force saturation limitation algorithm based on the tension and displacement transmission model of a cable-pulley system is proposed to improve the operation’s accuracy and safety. The algorithm considers the force and position transmission characteristics of each stage of the cable-pulley system including the transition stage. Experimental verifications show that the proposed algorithm can significantly improve the position tracking accuracy of surgical instruments and the safety of grasping operations.