Personalized application of three different concentrations of iodinated contrast media in coronary computed tomography angiography
Open Access
- 30 March 2020
- journal article
- research article
- Published by Wiley in Journal of Cellular and Molecular Medicine
- Vol. 24 (10) , 5446-5453
Abstract
No study has evaluated the impact of different iodinated contrast media on coronary contrast enhancement, using an injection protocol according to body surface area (BSA). Thus, the present study aimed to examine the usefulness and safety of personalized application of different iodine concentrations of contrast media in coronary computed tomographic (CT) angiography with a 2nd dual‐source CT scanner in eliminating differences in coronary contrast enhancement based on a BSA‐adapted injection protocol of contrast media. A total of 270 enrolled participants were randomly assigned to three groups: ioversol 320, ioversol 350 and iopromide 370 (n = 90 per group). The three groups were administered contrast media at a BSA‐adjusted volume and flow rate with a fixed injection time of 15 seconds, and they subsequently received a 30‐mL saline flush. All patients were scanned with a prospective electrocardiogram‐gated protocol in a craniocaudal direction using a second‐generation 128‐slice dual‐source CT system. The three iodinated contrast media used in coronary CT angiography exhibited similar diagnostic quality and safety. No significant differences were found in the contrast enhancement degrees, image quality scores, radiation doses and incidences of adverse effects among the three groups. The three contrast media used in coronary CT angiography with 320, 350 and 370 mg/mL iodine, respectively, have comparable diagnostic quality and safety. However, more large‐scale, multinational, multi‐centre and prospective trials are warranted.Keywords
Funding Information
- Natural Science Foundation of Shandong Province (ZR2019QH001, ZR2019BH021)
- National Natural Science Foundation of China (81770442, 81425004, 3177097, 81400284, 815703247)
This publication has 31 references indexed in Scilit:
- Comparison of Coronary Computed Tomography Angiography, Fractional Flow Reserve, and Perfusion Imaging for Ischemia DiagnosisJACC, 2019
- Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3rd generation dual-source CTEuropean Radiology, 2016
- Contrast-induced kidney injury: mechanisms, risk factors, and preventionEuropean Heart Journal, 2012
- Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and ApproachesRadiology, 2010
- Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggeringThe International Journal of Cardiovascular Imaging, 2009
- Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and ObesityAmerican Journal of Roentgenology, 2008
- Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiographyEuropean Radiology, 2007
- Determining Contrast Medium Dose and Rate on Basis of Lean Body Weight: Does This Strategy Improve Patient-to-Patient Uniformity of Hepatic Enhancement during Multi–Detector Row CT?Radiology, 2007
- Coronary Angiography by 64-Detector Row Computed Tomography Using Low Dose of Contrast Material with Saline ChaserJournal of Computer Assisted Tomography, 2007
- Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient WeightRadiology, 2004