Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography
Authors:
- Gabrielle IllavaGIGabrielle Illava
- Richard JayneRJRichard Jayne
- Aaron D. FinkeAFAaron D. Finke
- David ClossDCDavid Closs
- Wenjie ZengWZWenjie Zeng
- Shawn K. MilanoSMShawn K. Milano
- Qingqiu HuangQHQingqiu Huang
- Irina KriksunovIKIrina Kriksunov
- Pavel SidorenkoPSPavel Sidorenko
- Frank W. WiseFWFrank W. Wise
- Warren R. ZipfelWZWarren R. Zipfel
- Benjamin A. ApkerBABenjamin A. Apker
Open Access
- 19 April 2021
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 77 (5) , 628-644
Abstract
Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.Keywords
Funding Information
- U.S. Department of Energy (DE-SC0019546)
- National Science Foundation, Directorate for Mathematical and Physical Sciences (DMR-0936384)
- National Institutes of Health, National Institute of General Medical Sciences (GM-103485)
This publication has 84 references indexed in Scilit:
- Imaging of Protein Crystals with Two-Photon MicroscopyBiochemistry, 2012
- Screening of protein crystallization trials by second order nonlinear optical imaging of chiral crystals (SONICC)Methods, 2011
- Accessing protein conformational ensembles using room-temperature X-ray crystallographyProceedings of the National Academy of Sciences, 2011
- Femtosecond X-ray protein nanocrystallographyNature, 2011
- The minimum crystal size needed for a complete diffraction data setActa Crystallographica Section D Structural Biology, 2010
- XDSActa Crystallographica Section D Structural Biology, 2010
- Robust, high-throughput solution structural analyses by small angle X-ray scattering (SAXS)Nature Methods, 2009
- A beginner's guide to radiation damageJournal of Synchrotron Radiation, 2009
- Selection of Protein Crystal Forms Facilitated by Polymer-Induced HeteronucleationCrystal Growth & Design, 2007
- Hyperquenching for protein cryocrystallographyJournal of Applied Crystallography, 2006