Aaron D. Finke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aaron D. Finke has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
- François Diederich
Laboratory of Organic Chemistry Department of Chemistry and Applied Biosciences ETH Zurich, HCI Vladimir-Prelog-Weg 3 8093 Zurich Switzerland
11 shared publications Corinne Boudon
Laboratoire d'Electrochimie et de Chimie Physique du Corps Solide, Institut de Chimie-UMR 7177, C.N.R.S., Université de Strasbourg, 4 rue Blaise Pascal, CS 90032, 67081, Strasbourg Cedex, France
7 shared publicationsJeffrey S. Moore
University of Illinois, School of Chemical Sciences, Box 55-5, 600 South Mathews Avenue, Urbana, Illinois 61801, USA
5 shared publicationsW. Bernd Schweizer
Laboratorium für Organische Chemie, ETH Zurich, Vladimir-Prelog-Weg 3, 8093, Zurich, Switzerland), Fax: (+41) 44-632-1109
5 shared publicationsJean‐Paul Gisselbrecht
Laboratoire d'Electrochimie et de Chimie Physique du Corps Solide, Institut de Chimie-UMR 7177, C.N.R.S., Université de Strasbourg, 4 rue Blaise Pascal, CS 90032, 67081, Strasbourg Cedex, France
4 shared publications- Meitian Wang
Paul Scherrer Institute
4 shared publications
Latest Publications
- Open Access
- 21 June 2026
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 82 (7) , 751-760
Simulating neutron protein crystallography experiments: applications to the development of the NMX instrument at ESS
Monte Carlo neutron ray-tracing simulations of time-of-flight (TOF)–Laue neutron macromolecular crystal diffraction ( n -MX) using the McStas software package were performed for the upcoming NMX Macromolecular Diffractometer at the European Spallation Source. Splitting neutron rays that arrive at the crystal leads to dramatic improvements in event formation with minimal computational overhead. The simulated event-probability data were sampled using a new single-pass weighted reservoir-sampling method, and processed like real n -MX data using DIALS . The effects of air and beamstop scatter on simulated data were investigated.
- 21 June 2026
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 82 (7) , 751-760
Open AccessSimulating neutron protein crystallography experiments: applications to the development of the NMX instrument at ESS
Monte Carlo neutron ray-tracing simulations of time-of-flight (TOF)–Laue neutron macromolecular crystal diffraction ( n -MX) using the McStas software package were performed for the upcoming NMX Macromolecular Diffractometer at the European Spallation Source. Splitting neutron rays that arrive at the crystal leads to dramatic improvements in event formation with minimal computational overhead. The simulated event-probability data were sampled using a new single-pass weighted reservoir-sampling method, and processed like real n -MX data using DIALS . The effects of air and beamstop scatter on simulated data were investigated.
- Open Access
Simulating Neutron Protein Crystallography Experiments: Applications to the Development of the NMX Instrument at ESS
Monte Carlo neutron ray-tracing simulations of time-of-flight (TOF)-Laue neutron macromolecular crystal diffraction ( n -MX) using the McStas software package were done for the upcoming NMX Macromolecular Diffractometer at the European Spallation Source. Splitting neutron rays that arrive at the crystal lead to dramatic improvements in event formation with minimal computational overhead. The simulated event probability data was sampled using a new single-pass weighted reservoir sampling method, and processed like real n -MX data using DIALS. The effects of air and beamstop scatter on simulated data was investigated. Synopsis: Monte Carlo simulations of neutron protein diffraction experiments provide useful data that models instrumental components that interact with neutrons, as well as the crystal diffraction itself. These data can be applied to instrument development, such as the commissioning of the NMX Macromolecular Diffractometer at ESS.
Open AccessSimulating Neutron Protein Crystallography Experiments: Applications to the Development of the NMX Instrument at ESS
Monte Carlo neutron ray-tracing simulations of time-of-flight (TOF)-Laue neutron macromolecular crystal diffraction ( n -MX) using the McStas software package were done for the upcoming NMX Macromolecular Diffractometer at the European Spallation Source. Splitting neutron rays that arrive at the crystal lead to dramatic improvements in event formation with minimal computational overhead. The simulated event probability data was sampled using a new single-pass weighted reservoir sampling method, and processed like real n -MX data using DIALS. The effects of air and beamstop scatter on simulated data was investigated. Synopsis: Monte Carlo simulations of neutron protein diffraction experiments provide useful data that models instrumental components that interact with neutrons, as well as the crystal diffraction itself. These data can be applied to instrument development, such as the commissioning of the NMX Macromolecular Diffractometer at ESS.
- Open Access
Pushed to extremes: distinct effects of high temperature vs. pressure on the structure of an atypical phosphatase
Protein function hinges on small shifts of three-dimensional structure. Elevating temperature or pressure may provide experimentally accessible insights into such shifts, but the effects of these distinct perturbations on protein structures have not been compared in atomic detail. To quantitatively explore these two axes, we report the first pair of structures at physiological temperature vs. high pressure for the same protein, STEP (PTPN5). We show that these perturbations have distinct and surprising effects on protein volume, patterns of ordered solvent, and local backbone and side-chain conformations. This includes novel interactions between key catalytic loops only at physiological temperature, and a distinct conformational ensemble for another active-site loop only at high pressure. Strikingly, in torsional space, physiological temperature shifts STEP toward previously reported active-like states, while high pressure shifts it toward a previously uncharted region. Together, our work argues that temperature and pressure are complementary, powerful, fundamental macromolecular perturbations.
Open AccessPushed to extremes: distinct effects of high temperature vs. pressure on the structure of an atypical phosphatase
Protein function hinges on small shifts of three-dimensional structure. Elevating temperature or pressure may provide experimentally accessible insights into such shifts, but the effects of these distinct perturbations on protein structures have not been compared in atomic detail. To quantitatively explore these two axes, we report the first pair of structures at physiological temperature vs. high pressure for the same protein, STEP (PTPN5). We show that these perturbations have distinct and surprising effects on protein volume, patterns of ordered solvent, and local backbone and side-chain conformations. This includes novel interactions between key catalytic loops only at physiological temperature, and a distinct conformational ensemble for another active-site loop only at high pressure. Strikingly, in torsional space, physiological temperature shifts STEP toward previously reported active-like states, while high pressure shifts it toward a previously uncharted region. Together, our work argues that temperature and pressure are complementary, powerful, fundamental macromolecular perturbations.
- Open Access
- 19 April 2021
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 77 (5) , 628-644
Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography
Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.
- 19 April 2021
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 77 (5) , 628-644
Open AccessIntegrated sample-handling and mounting system for fixed-target serial synchrotron crystallography
Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.
- Open Access
- 1 March 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 75 (3) , 262-271
Making routine native SAD a reality: lessons from beamline X06DA at the Swiss Light Source
Native single-wavelength anomalous dispersion (SAD) is the most attractive de novo phasing method in macromolecular crystallography, as it directly utilizes intrinsic anomalous scattering from native crystals. However, the success of such an experiment depends on accurate measurements of the reflection intensities and therefore on careful data-collection protocols. Here, the low-dose, multiple-orientation data-collection protocol for native SAD phasing developed at beamline X06DA (PXIII) at the Swiss Light Source is reviewed, and its usage over the last four years on conventional crystals (>50 µm) is reported. Being experimentally very simple and fast, this method has gained popularity and has delivered 45 de novo structures to date (13 of which have been published). Native SAD is currently the primary choice for experimental phasing among X06DA users. The method can address challenging cases: here, native SAD phasing performed on a streptavidin–biotin crystal with P21 symmetry and a low Bijvoet ratio of 0.6% is highlighted. The use of intrinsic anomalous signals as sequence markers for model building and the assignment of ions is also briefly described.
- 1 March 2019
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 75 (3) , 262-271
Open AccessMaking routine native SAD a reality: lessons from beamline X06DA at the Swiss Light Source
Native single-wavelength anomalous dispersion (SAD) is the most attractive de novo phasing method in macromolecular crystallography, as it directly utilizes intrinsic anomalous scattering from native crystals. However, the success of such an experiment depends on accurate measurements of the reflection intensities and therefore on careful data-collection protocols. Here, the low-dose, multiple-orientation data-collection protocol for native SAD phasing developed at beamline X06DA (PXIII) at the Swiss Light Source is reviewed, and its usage over the last four years on conventional crystals (>50 µm) is reported. Being experimentally very simple and fast, this method has gained popularity and has delivered 45 de novo structures to date (13 of which have been published). Native SAD is currently the primary choice for experimental phasing among X06DA users. The method can address challenging cases: here, native SAD phasing performed on a streptavidin–biotin crystal with P21 symmetry and a low Bijvoet ratio of 0.6% is highlighted. The use of intrinsic anomalous signals as sequence markers for model building and the assignment of ions is also briefly described.
- Open Access
- 23 February 2019
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 6 (2) , 305-316
Fixed-target serial oscillation crystallography at room temperature
A fixed-target approach to high-throughput room-temperature serial synchrotron crystallography with oscillation is described. Patterned silicon chips with microwells provide high crystal-loading density with an extremely high hit rate. The microfocus, undulator-fed beamline at CHESS, which has compound refractive optics and a fast-framing detector, was built and optimized for this experiment. The high-throughput oscillation method described here collects 1–5° of data per crystal at room temperature with fast (10° s−1) oscillation rates and translation times, giving a crystal-data collection rate of 2.5 Hz. Partial datasets collected by the oscillation method at a storage-ring source provide more complete data per crystal than still images, dramatically lowering the total number of crystals needed for a complete dataset suitable for structure solution and refinement – up to two orders of magnitude fewer being required. Thus, this method is particularly well suited to instances where crystal quantities are low. It is demonstrated, through comparison of first and last oscillation images of two systems, that dose and the effects of radiation damage can be minimized through fast rotation and low angular sweeps for each crystal.
- 23 February 2019
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 6 (2) , 305-316
Open AccessFixed-target serial oscillation crystallography at room temperature
A fixed-target approach to high-throughput room-temperature serial synchrotron crystallography with oscillation is described. Patterned silicon chips with microwells provide high crystal-loading density with an extremely high hit rate. The microfocus, undulator-fed beamline at CHESS, which has compound refractive optics and a fast-framing detector, was built and optimized for this experiment. The high-throughput oscillation method described here collects 1–5° of data per crystal at room temperature with fast (10° s−1) oscillation rates and translation times, giving a crystal-data collection rate of 2.5 Hz. Partial datasets collected by the oscillation method at a storage-ring source provide more complete data per crystal than still images, dramatically lowering the total number of crystals needed for a complete dataset suitable for structure solution and refinement – up to two orders of magnitude fewer being required. Thus, this method is particularly well suited to instances where crystal quantities are low. It is demonstrated, through comparison of first and last oscillation images of two systems, that dose and the effects of radiation damage can be minimized through fast rotation and low angular sweeps for each crystal.
- 10 August 2018
- Published by Wiley in Chemistry – A European Journal
- Vol. 24 (51) , 13616-13623
Charge‐Transfer Salts of 6,6‐Dicyanopentafulvenes: From Topology to Charge Separation in Solution
6,6‐Dicyanopentafulvene derivatives and metallocenes with redox potentials appropriate for forming their radical anions form highly persistent donor–acceptor salts. The charge‐transfer salts of 2,3,4,5‐tetraphenyl‐6,6‐dicyanofulvene with cobaltocene (1⋅Cp2Co) and 2,3,4,5‐tetrakis(triisopropylsilyl)‐6,6‐dicyanofulvene with decamethylferrocene (2⋅Fc*) have been prepared. The X‐ray structures of the two salts, formed as black plates, were obtained and are discussed herein. Compared with neutral dicyanopentafulvenes, the chromophores in the metallocene salts show substantial changes in bond lengths and torsional angles in the solid state. EPR, NMR, and optical spectroscopy, as well as superconducting quantum interference device (SQUID) measurements, reveal that charge‐separation in the crystalline states and in frozen and fluid solutions depends on subtle differences of redox potentials, geometry, and on ion pairing. Whereas 1⋅Cp2Co reveals paramagnetic character in the crystalline state and in solution, compound 2⋅Fc* shows a delicate balance between para‐ and diamagnetism, depending on the temperature and solvent characteristics.
- 10 August 2018
- Published by Wiley in Chemistry – A European Journal
- Vol. 24 (51) , 13616-13623
Charge‐Transfer Salts of 6,6‐Dicyanopentafulvenes: From Topology to Charge Separation in Solution
6,6‐Dicyanopentafulvene derivatives and metallocenes with redox potentials appropriate for forming their radical anions form highly persistent donor–acceptor salts. The charge‐transfer salts of 2,3,4,5‐tetraphenyl‐6,6‐dicyanofulvene with cobaltocene (1⋅Cp2Co) and 2,3,4,5‐tetrakis(triisopropylsilyl)‐6,6‐dicyanofulvene with decamethylferrocene (2⋅Fc*) have been prepared. The X‐ray structures of the two salts, formed as black plates, were obtained and are discussed herein. Compared with neutral dicyanopentafulvenes, the chromophores in the metallocene salts show substantial changes in bond lengths and torsional angles in the solid state. EPR, NMR, and optical spectroscopy, as well as superconducting quantum interference device (SQUID) measurements, reveal that charge‐separation in the crystalline states and in frozen and fluid solutions depends on subtle differences of redox potentials, geometry, and on ion pairing. Whereas 1⋅Cp2Co reveals paramagnetic character in the crystalline state and in solution, compound 2⋅Fc* shows a delicate balance between para‐ and diamagnetism, depending on the temperature and solvent characteristics.
- 6 October 2016
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 55 (47) , 14648-14652
Pentaindenocorannulene: Properties, Assemblies, and C60 Complex
Pentaindenocorannulene (C50H20 , 1), a deep bowl polynuclear aromatic hydrocarbon, accepts 4 electrons, crystallizes in columnar bowl‐in‐bowl assemblies and forms a nested C60@12 complex. Spectra, structures and computations are presented.
- 6 October 2016
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 55 (47) , 14648-14652
Pentaindenocorannulene: Properties, Assemblies, and C60 Complex
Pentaindenocorannulene (C50H20 , 1), a deep bowl polynuclear aromatic hydrocarbon, accepts 4 electrons, crystallizes in columnar bowl‐in‐bowl assemblies and forms a nested C60@12 complex. Spectra, structures and computations are presented.
- Open Access
- 31 August 2016
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 72 (9) , 1036-1048
EIGER detector: application in macromolecular crystallography
The development of single-photon-counting detectors, such as the PILATUS, has been a major recent breakthrough in macromolecular crystallography, enabling noise-free detection and novel data-acquisition modes. The new EIGER detector features a pixel size of 75 × 75 µm, frame rates of up to 3000 Hz and a dead time as low as 3.8 µs. An EIGER 1M and EIGER 16M were tested on Swiss Light Source beamlines X10SA and X06SA for their application in macromolecular crystallography. The combination of fast frame rates and a very short dead time allows high-quality data acquisition in a shorter time. The ultrafine φ-slicing data-collection method is introduced and validated and its application in finding the optimal rotation angle, a suitable rotation speed and a sufficient X-ray dose are presented. An improvement of the data quality up to slicing at one tenth of the mosaicity has been observed, which is much finer than expected based on previous findings. The influence of key data-collection parameters on data quality is discussed.
- 31 August 2016
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section D Structural Biology
- Vol. 72 (9) , 1036-1048
Open AccessEIGER detector: application in macromolecular crystallography
The development of single-photon-counting detectors, such as the PILATUS, has been a major recent breakthrough in macromolecular crystallography, enabling noise-free detection and novel data-acquisition modes. The new EIGER detector features a pixel size of 75 × 75 µm, frame rates of up to 3000 Hz and a dead time as low as 3.8 µs. An EIGER 1M and EIGER 16M were tested on Swiss Light Source beamlines X10SA and X06SA for their application in macromolecular crystallography. The combination of fast frame rates and a very short dead time allows high-quality data acquisition in a shorter time. The ultrafine φ-slicing data-collection method is introduced and validated and its application in finding the optimal rotation angle, a suitable rotation speed and a sufficient X-ray dose are presented. An improvement of the data quality up to slicing at one tenth of the mosaicity has been observed, which is much finer than expected based on previous findings. The influence of key data-collection parameters on data quality is discussed.
- 1 July 2016
- Published by Wiley in Chemistry – A European Journal
- Vol. 22 (30) , 10539-10547
Design and Synthesis of Aviram–Ratner‐Type Dyads and Rectification Studies in Langmuir–Blodgett (LB) Films
The design and synthesis of Aviram–Ratner‐type molecular rectifiers, featuring an anilino‐substituted extended tetracyanoquinodimethane (exTCNQ) acceptor, covalently linked by the σ‐spacer bicyclo[2.2.2]octane (BCO) to a tetrathiafulvalene (TTF) donor moiety, are described. The rigid BCO spacer keeps the TTF donor and exTCNQ acceptor moieties apart, as demonstrated by X‐ray analysis. The photophysical properties of the TTF‐BCO‐exTCNQ dyads were investigated by UV/Vis and EPR spectroscopy, electrochemical studies, and theoretical calculations. Langmuir–Blodgett films were prepared and used in the fabrication and electrical studies of junction devices. One dyad showed the asymmetric current–voltage (I–V) curve characteristic for rectification, unlike control compounds containing the TTF unit but not the exTCNQ moiety or comprising the exTCNQ acceptor moiety but lacking the donor TTF part, which both gave symmetric I–V curves. The direction of the observed rectification indicated that the preferred electron current flows from the exTCNQ acceptor to the TTF donor.
- 1 July 2016
- Published by Wiley in Chemistry – A European Journal
- Vol. 22 (30) , 10539-10547
Design and Synthesis of Aviram–Ratner‐Type Dyads and Rectification Studies in Langmuir–Blodgett (LB) Films
The design and synthesis of Aviram–Ratner‐type molecular rectifiers, featuring an anilino‐substituted extended tetracyanoquinodimethane (exTCNQ) acceptor, covalently linked by the σ‐spacer bicyclo[2.2.2]octane (BCO) to a tetrathiafulvalene (TTF) donor moiety, are described. The rigid BCO spacer keeps the TTF donor and exTCNQ acceptor moieties apart, as demonstrated by X‐ray analysis. The photophysical properties of the TTF‐BCO‐exTCNQ dyads were investigated by UV/Vis and EPR spectroscopy, electrochemical studies, and theoretical calculations. Langmuir–Blodgett films were prepared and used in the fabrication and electrical studies of junction devices. One dyad showed the asymmetric current–voltage (I–V) curve characteristic for rectification, unlike control compounds containing the TTF unit but not the exTCNQ moiety or comprising the exTCNQ acceptor moiety but lacking the donor TTF part, which both gave symmetric I–V curves. The direction of the observed rectification indicated that the preferred electron current flows from the exTCNQ acceptor to the TTF donor.