Magnetically shielded rooms (MSRs) provide a near-zero field environment for magnetoencephalography (MEG) research. Due to the high cost of high-permeability materials and the weak shielding capability against low-frequency magnetic disturbance, it is necessary to further design active compensation coils combined with a closed-loop control system to achieve dynamic nulling of environmental magnetic disturbance. To enhance the performance of the dynamic nulling system, this paper proposes a novel controller design method based on Padé approximation and generalized active disturbance rejection control (GADRC). First, a precise closed-loop model of the dynamic nulling system is established. On this basis, the delay element of the optically pumped magnetometer (OPM) is approximated using the Padé approximation method, and the controller is designed within the GADRC framework. The system’s stability and disturbance suppression capability are analyzed using frequency-domain methods. To validate the effectiveness of the proposed method, simulations and experiments are conducted, achieving a shielding factor greater than 40 dB at 0.1 Hz. After filtering out power frequency interference, the peak-to-peak field fluctuation is reduced from 320.3 pT to 1.8 pT.Keywords
Funding Information
- National Natural Science Foundation of China (52075017, 62122009)
This publication has 27 references indexed in Scilit:
- Magnetic field interference suppression for minimized SERF atomic magnetometerSensors and Actuators A: Physical, 2023
- Magnetoencephalography with optically pumped magnetometers (OPM-MEG): the next generation of functional neuroimagingTrends in Neurosciences, 2022
- Using OPM-MEG in contrasting magnetic environmentsNeuroImage, 2022
- Precision magnetic field modelling and control for wearable magnetoencephalographyNeuroImage, 2021
- Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalographyNeuroImage, 2019
- Potential of on‐scalp MEG: Robust detection of human visual gamma‐band responsesHuman Brain Mapping, 2019
- On-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometersNeuroImage, 2019
- Cognitive neuroscience using wearable magnetometer arrays: Non-invasive assessment of language functionNeuroImage, 2018
- Measuring MEG closer to the brain: Performance of on-scalp sensor arraysNeuroImage, 2017
- Tuning of linear ADRC with known plant informationISA Transactions, 2016