Electrically Evoked Auditory Brainstem Responses in Adults and Children
Authors:
- Christina Runge-SamuelsonCRChristina Runge-Samuelson
- Jill B. FirsztJFJill B. Firszt
- Wolfgang GagglWGWolfgang Gaggl
- P. Ashley WackymPWP. Ashley Wackym
- 1 June 2009
- journal article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 30 (4) , 464-470
Abstract
Previous electrophysiologic studies of electrode placement within the scala tympani in both animals and humans have shown effects on neural responses to electrical stimulation. The specific effects, however, may be dependent on electrode design, the location of an electrode along the array, and the method of perimodiolar positioning. The present study compares the effects of lateral and medial positioning of the Nucleus Contour electrode array on electrophysiologic responses in adult and pediatric subjects. Prospective clinical study. Comprehensive Cochlear Implant Program/Tertiary Referral Center. Subjects were adults (n = 15) and children (n = 20) who were consecutively implanted at our center with the Nucleus 24 Contour device. Rehabilitative. Intraoperative electrically evoked auditory brainstem responses (EABRs) were recorded within subjects for lateral and medial placement of the electrode array. Effects of electrode placement on EABR Wave V threshold and suprathreshold amplitude were measured. Group analyses showed significant decreases in EABR threshold and significant increases in EABR amplitude across all electrodes with medial electrode placement. The effects differed across electrode locations for the adult and pediatric subjects. No significant changes in Wave V input/output function slope were found. Medial electrode placement from stylet removal with the Nucleus 24 Contour array results in an increased neural response compared with the lateral condition as demonstrated by lower threshold and larger suprathreshold amplitude of the EABR. Possible clinical implications of these findings are lower psychophysical threshold and comfortable levels with medial cochlear electrode position.Keywords
This publication has 16 references indexed in Scilit:
- Psychophysical measures in patients fitted with Contour™ and straight Nucleus electrode arraysHearing Research, 2006
- Electrophysiologic Effects of Placing Cochlear Implant Electrodes in a Perimodiolar Position in Young ChildrenThe Laryngoscope, 2004
- The Clarion Electrode Positioner: Approximation to the Medial Wall and Current Focussing?Audiology and Neurotology, 2003
- Electrically Evoked Auditory Brain Stem Responses for Lateral and Medial Placement of the Clarion HiFocus ElectrodeEar & Hearing, 2003
- Threshold, Comfortable Level and Impedance Changes as a Function of Electrode-Modiolar DistanceEar & Hearing, 2002
- The Nucleus?? 24 Contour??? Cochlear Implant System: Adult Clinical Trial ResultsEar & Hearing, 2002
- Psychophysics of a prototype peri-modiolar cochlear implant electrode arrayHearing Research, 2001
- The Importance of Human Cochlear Anatomy for the Results of Modiolus-Hugging Multichannel Cochlear ImplantsOtology & Neurotology, 2001
- Intracochlear Factors Contributing to Psychophysical Percepts Following Cochlear ImplantationActa Oto-Laryngologica, 1998
- Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitationHearing Research, 1993