Portable Gamma Irradiation System with 57Co, 133Ba, 137Cs, and 60Co for On-site Calibration of Environmental Radiation Monitoring Devices
Open Access
- 30 December 2024
- journal article
- research article
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 49 (4) , 166-173
Abstract
Background: A portable gamma irradiation system was developed for on-site calibration of environmental radiation monitoring devices. This system uses a portable collimator and gammaray sources such as 57Co, 133Ba, 137Cs, and 60Co, each with a nominal radioactivity of 10 MBq or less.Materials and Methods: The air kerma rate produced by the system was measured using a spherical ionization chamber with a 10 L sensitive volume. This chamber was calibrated against the air kerma rate measured with primary standard ionization chambers. The system’s performance was evaluated by comparing the calibration results of the monitoring device with those obtained using a conventional method involving a standard ionization chamber for outdoor use.Results and Discussion: The calibration coefficient of the spherical ionization chamber was within ±2% of the value of 3.029×103 Gy/C for photon energies ranging from 50 keV to 1,250 keV. The air kerma rate of the irradiation field produced by the portable system ranged from 0.17 μGy/hr to 4.7 μGy/hr, with an uncertainty between 2.4% and 10%. The calibration coefficients obtained using the portable system were consistent with those from the conventional method.Conclusion: The portable gamma irradiation system offers significant advantages, including preventing damage to standard ionization chambers used outdoors and reducing measurement time compared to conventional methods. Due to its ease of construction and implementation, the system is expected to be useful not only for on-site calibration of monitoring devices but also in various radiation safety management scenarios.Keywords
Funding Information
- Radiation Safety Research Promotion Fund
- Nuclear Facility Disaster Prevention Fund
This publication has 10 references indexed in Scilit:
- Subfemtoampere Resolved Ionization Current Measurements Using a High-Resistance Transimpedance AmplifierIEEE Transactions on Instrumentation and Measurement, 2022
- Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NMIJ, Japan and the BIPM in 60Co gamma radiationMetrologia, 2022
- The NMIJ air kerma primary standard for high energy x-ray beams in 300–450 kVBiomedical Physics & Engineering Express, 2021
- ESTABLISHMENT OF A LOW DOSE RATE GAMMA RAY CALIBRATION FIELD FOR ENVIRONMENTAL RADIATION MONITORING DEVICESRadiation Protection Dosimetry, 2019
- A new apparatus for on-site calibration of gamma dose rate monitorsReview of Scientific Instruments, 2018
- Key comparison BIPM.RI(I)-K5 of the air kerma standards of the NMIJ, Japan and the BIPM in137Cs gamma radiationMetrologia, 2013
- CHANGES OF RADIONUCLIDES IN THE ENVIRONMENT IN CHIBA, JAPAN, AFTER THE FUKUSHIMA NUCLEAR POWER PLANT ACCIDENTHealth Physics, 2012
- The time variation of dose rate artificially increased by the Fukushima nuclear crisisScientific Reports, 2011
- Traceability of the PTB low-dose rate photon calibration facilityRadiation Protection Dosimetry, 2010
- A new approach to the determination of air kerma using primary-standard cavity ionization chambersPhysics in Medicine & Biology, 2006