Junya Ishii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junya Ishii has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Tadahiro Kurosawa
Natl Metrol Inst Japan, Natl Inst Adv Ind Sci & Technol, Tsukuba, Japan
4 shared publicationsMasahiro Kato
Natl Metrol Inst Japan, Natl Inst Adv Ind Sci & Technol, Tsukuba, Japan
3 shared publications- Hiroshi Watabe
Tohoku University
2 shared publications - Masahiro Kato
National Metrology Institute of Japan National Institute of Advanced Industrial Science and Technology Tsukuba Japan
2 shared publications - Morihito Shimizu
National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial Science and Technology (AIST) Tsukuba Ibaraki Japan
2 shared publications - Tadahiro Kurosawa
National Metrology Institute of Japan, National Institute of Advanced Industrial Science and Technology
2 shared publications
Latest Publications
- Open Access
- 7 February 2026
- Published by Elsevier in SSRN Electronic Journal
Demonstration of self-powered wireless transmission using a gamma-ray battery in a nuclear decommissioning environment
Wireless communication in nuclear decommissioning environments is severely constrained by the difficulty of providing external power sources and by the high radiation fields that limit conventional electronics. Gamma radiation, however, is continuously present in such environments and can potentially be exploited as an energy source for self-powered systems.In this study, we demonstrate self-powered wireless transmission using a gamma-ray battery composed of GaInP photovoltaic cells coupled with a CsI(Tl) scintillator, integrated with an ultra-low-power power management circuit and a sub-GHz wireless transmitter.Field experiments were conducted at the Fukushima Daiichi Nuclear Power Plant at a deliberately selected location inside a contaminated-material storage facility that contains relatively high-activity items. At the device position, the local ambient gamma-ray field was approximately 35 mSv/h, where limited human access is permitted under controlled conditions during decommissioning operations. The gamma-ray battery generated electrical power on the order of 1 μW, which was stored in a thin-film secondary battery and intermittently supplied to the wireless communication module. Without external power supply, multiple wireless transmission events were successfully observed over several hours, demonstrating that gamma-ray energy harvesting can sustain autonomous wireless communication in a real nuclear decommissioning environment.The evolution of the storage voltage before and after the transmission events indicates that gamma-ray energy harvesting replenished a substantial fraction of the energy consumed during communication. At the same time, the experiments revealed that the cold-start power requirement of the power management circuit constitutes a critical limiting factor for repeated autonomous restart under ultra-low-power gamma-ray harvesting conditions.These results provide experimental evidence that gamma-ray batteries can enable self-powered wireless transmission in nuclear decommissioning environments and clarify key design constraints for long-term monitoring systems. The demonstrated approach has potential applications in communication modules for decommissioning operations and in permanently installed monitoring devices for radioactive waste management.
- 7 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDemonstration of self-powered wireless transmission using a gamma-ray battery in a nuclear decommissioning environment
Wireless communication in nuclear decommissioning environments is severely constrained by the difficulty of providing external power sources and by the high radiation fields that limit conventional electronics. Gamma radiation, however, is continuously present in such environments and can potentially be exploited as an energy source for self-powered systems.In this study, we demonstrate self-powered wireless transmission using a gamma-ray battery composed of GaInP photovoltaic cells coupled with a CsI(Tl) scintillator, integrated with an ultra-low-power power management circuit and a sub-GHz wireless transmitter.Field experiments were conducted at the Fukushima Daiichi Nuclear Power Plant at a deliberately selected location inside a contaminated-material storage facility that contains relatively high-activity items. At the device position, the local ambient gamma-ray field was approximately 35 mSv/h, where limited human access is permitted under controlled conditions during decommissioning operations. The gamma-ray battery generated electrical power on the order of 1 μW, which was stored in a thin-film secondary battery and intermittently supplied to the wireless communication module. Without external power supply, multiple wireless transmission events were successfully observed over several hours, demonstrating that gamma-ray energy harvesting can sustain autonomous wireless communication in a real nuclear decommissioning environment.The evolution of the storage voltage before and after the transmission events indicates that gamma-ray energy harvesting replenished a substantial fraction of the energy consumed during communication. At the same time, the experiments revealed that the cold-start power requirement of the power management circuit constitutes a critical limiting factor for repeated autonomous restart under ultra-low-power gamma-ray harvesting conditions.These results provide experimental evidence that gamma-ray batteries can enable self-powered wireless transmission in nuclear decommissioning environments and clarify key design constraints for long-term monitoring systems. The demonstrated approach has potential applications in communication modules for decommissioning operations and in permanently installed monitoring devices for radioactive waste management.
- Open Access
- 31 December 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
Performance evaluation of a silicon carbide semiconductor-based neutron detector for neutron-gamma discrimination
- 31 December 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1084
Open AccessPerformance evaluation of a silicon carbide semiconductor-based neutron detector for neutron-gamma discrimination
- Open Access
- 30 December 2024
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 49 (4) , 166-173
Portable Gamma Irradiation System with 57Co, 133Ba, 137Cs, and 60Co for On-site Calibration of Environmental Radiation Monitoring Devices
Background: A portable gamma irradiation system was developed for on-site calibration of environmental radiation monitoring devices. This system uses a portable collimator and gammaray sources such as 57Co, 133Ba, 137Cs, and 60Co, each with a nominal radioactivity of 10 MBq or less.Materials and Methods: The air kerma rate produced by the system was measured using a spherical ionization chamber with a 10 L sensitive volume. This chamber was calibrated against the air kerma rate measured with primary standard ionization chambers. The system’s performance was evaluated by comparing the calibration results of the monitoring device with those obtained using a conventional method involving a standard ionization chamber for outdoor use.Results and Discussion: The calibration coefficient of the spherical ionization chamber was within ±2% of the value of 3.029×103 Gy/C for photon energies ranging from 50 keV to 1,250 keV. The air kerma rate of the irradiation field produced by the portable system ranged from 0.17 μGy/hr to 4.7 μGy/hr, with an uncertainty between 2.4% and 10%. The calibration coefficients obtained using the portable system were consistent with those from the conventional method.Conclusion: The portable gamma irradiation system offers significant advantages, including preventing damage to standard ionization chambers used outdoors and reducing measurement time compared to conventional methods. Due to its ease of construction and implementation, the system is expected to be useful not only for on-site calibration of monitoring devices but also in various radiation safety management scenarios.
- 30 December 2024
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 49 (4) , 166-173
Open AccessPortable Gamma Irradiation System with 57Co, 133Ba, 137Cs, and 60Co for On-site Calibration of Environmental Radiation Monitoring Devices
Background: A portable gamma irradiation system was developed for on-site calibration of environmental radiation monitoring devices. This system uses a portable collimator and gammaray sources such as 57Co, 133Ba, 137Cs, and 60Co, each with a nominal radioactivity of 10 MBq or less.Materials and Methods: The air kerma rate produced by the system was measured using a spherical ionization chamber with a 10 L sensitive volume. This chamber was calibrated against the air kerma rate measured with primary standard ionization chambers. The system’s performance was evaluated by comparing the calibration results of the monitoring device with those obtained using a conventional method involving a standard ionization chamber for outdoor use.Results and Discussion: The calibration coefficient of the spherical ionization chamber was within ±2% of the value of 3.029×103 Gy/C for photon energies ranging from 50 keV to 1,250 keV. The air kerma rate of the irradiation field produced by the portable system ranged from 0.17 μGy/hr to 4.7 μGy/hr, with an uncertainty between 2.4% and 10%. The calibration coefficients obtained using the portable system were consistent with those from the conventional method.Conclusion: The portable gamma irradiation system offers significant advantages, including preventing damage to standard ionization chambers used outdoors and reducing measurement time compared to conventional methods. Due to its ease of construction and implementation, the system is expected to be useful not only for on-site calibration of monitoring devices but also in various radiation safety management scenarios.
- 1 September 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (3) , 031516
Cavity ionization chamber responses in the JAEA and the NMIJ high-energy photon reference fields for radiation protection
A dosimeter should ideally be calibrated in a reference field with similar energy and doserate to that which the dosimeter is being used to measure. Environments around nuclear reactors and radiation therapy facilities have high-energy photons with energies exceeding that of 60Co gamma rays, and controlling exposure to these photons is important. The Japan Atomic Energy Agency and National Metrology Institute of Japan have high-energy reference fields with energies above several megaelectronvolts for different types of accelerators. Their reference fields have different fluence-energy distributions. In this study, the energy dependencies of the two-cavity ionization chambers, which are often used by secondary standard laboratories, were experimentally and computationally evaluated for each high-energy field. These results agreed well within the relative expanded uncertainties (k = 2), and their capabilities for air kerma measurements in each high-energy reference field were confirmed. Therefore, the capabilities of the air-kerma measurements were verified in the two high-energy reference fields.
- 1 September 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (3) , 031516
Cavity ionization chamber responses in the JAEA and the NMIJ high-energy photon reference fields for radiation protection
A dosimeter should ideally be calibrated in a reference field with similar energy and doserate to that which the dosimeter is being used to measure. Environments around nuclear reactors and radiation therapy facilities have high-energy photons with energies exceeding that of 60Co gamma rays, and controlling exposure to these photons is important. The Japan Atomic Energy Agency and National Metrology Institute of Japan have high-energy reference fields with energies above several megaelectronvolts for different types of accelerators. Their reference fields have different fluence-energy distributions. In this study, the energy dependencies of the two-cavity ionization chambers, which are often used by secondary standard laboratories, were experimentally and computationally evaluated for each high-energy field. These results agreed well within the relative expanded uncertainties (k = 2), and their capabilities for air kerma measurements in each high-energy reference field were confirmed. Therefore, the capabilities of the air-kerma measurements were verified in the two high-energy reference fields.
- 25 January 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (1) , 011504
Air kerma reference field with high energy photons using a 15 MeV electron beam from a clinical linear accelerator
In the medical and nuclear fields, there are environments where exposure to photons with energies above several MeV can result in problems. The National Metrology Institute of Japan has developed a high-energy photon field using a 15 MeV electron beam of a clinical linear accelerator with a copper target and an aluminium filter unit to facilitate dosimeter calibration in terms of air kerma. To determine the air kerma rate, the energy fluence distribution at a reference point was calculated, and both calculations and experiments evaluated the effective energy and spatial dose distribution. Moreover, to validate the air kerma measurement, two commercial cavity chambers were calibrated in a developed photon field. The results obtained exhibited a 4% difference compared with those in a Co-60 γ-ray reference field.
- 25 January 2024
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (1) , 011504
Air kerma reference field with high energy photons using a 15 MeV electron beam from a clinical linear accelerator
In the medical and nuclear fields, there are environments where exposure to photons with energies above several MeV can result in problems. The National Metrology Institute of Japan has developed a high-energy photon field using a 15 MeV electron beam of a clinical linear accelerator with a copper target and an aluminium filter unit to facilitate dosimeter calibration in terms of air kerma. To determine the air kerma rate, the energy fluence distribution at a reference point was calculated, and both calculations and experiments evaluated the effective energy and spatial dose distribution. Moreover, to validate the air kerma measurement, two commercial cavity chambers were calibrated in a developed photon field. The results obtained exhibited a 4% difference compared with those in a Co-60 γ-ray reference field.
- Open Access
- 4 July 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (4) , 042101
Accelerator-driven photon reference field for replacement of 137Cs γ-ray
A transition to a mechanical source for x-ray reference field is desired to replace high-activity Co-60 and Cs-137 gamma-ray sources for enhancing nuclear security and safety management. The National Metrology Institute of Japan (NMIJ) developed a new photon reference field using an electron beam from a linac with energy less than 1 MeV. The effective energy of the photon field is comparable with Cs-137 gamma-ray. The air kerma rate in the reference field was validated by comparing a commercial cavity ionization chamber to the NMIJ standard reference field. The calibration constants were consistent within 0.8% for every relative extended uncertainty (k = 2).
- 4 July 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (4) , 042101
Open AccessAccelerator-driven photon reference field for replacement of 137Cs γ-ray
A transition to a mechanical source for x-ray reference field is desired to replace high-activity Co-60 and Cs-137 gamma-ray sources for enhancing nuclear security and safety management. The National Metrology Institute of Japan (NMIJ) developed a new photon reference field using an electron beam from a linac with energy less than 1 MeV. The effective energy of the photon field is comparable with Cs-137 gamma-ray. The air kerma rate in the reference field was validated by comparing a commercial cavity ionization chamber to the NMIJ standard reference field. The calibration constants were consistent within 0.8% for every relative extended uncertainty (k = 2).
- Open Access
- 16 December 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 015021
The NMIJ air kerma primary standard for high energy x-ray beams in 300–450 kV
Accurate radiation dosimetry is required for radiation protection in various environments. Therefore, dosemeters and dose-rate meters must be calibrated in standard radiation fields. The National Metrology Institute of Japan (NMIJ) expands the energy range of x-ray reference field measurement up to 450 kV using a cylindrical graphite-walled cavity ionization chamber. Departure from the condition of the Spencer-Attix cavity theory was evaluated by comparing the measurement results obtained using the cavity ionization and the free-air ionization chambers, which are used as the primary standard up to a tube voltage of 250 kV. The calibration coefficients found using the spherical ionization chamber were in good agreement with those obtained by the free-air ionization chamber within relative standard uncertainties (k = 1) for N-200 and N-250 x-ray fields. Consistent calibration coefficients were obtained in the energy range 300–450 kV.
- 16 December 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 8 (1) , 015021
Open AccessThe NMIJ air kerma primary standard for high energy x-ray beams in 300–450 kV
Accurate radiation dosimetry is required for radiation protection in various environments. Therefore, dosemeters and dose-rate meters must be calibrated in standard radiation fields. The National Metrology Institute of Japan (NMIJ) expands the energy range of x-ray reference field measurement up to 450 kV using a cylindrical graphite-walled cavity ionization chamber. Departure from the condition of the Spencer-Attix cavity theory was evaluated by comparing the measurement results obtained using the cavity ionization and the free-air ionization chambers, which are used as the primary standard up to a tube voltage of 250 kV. The calibration coefficients found using the spherical ionization chamber were in good agreement with those obtained by the free-air ionization chamber within relative standard uncertainties (k = 1) for N-200 and N-250 x-ray fields. Consistent calibration coefficients were obtained in the energy range 300–450 kV.
- 1 January 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (1A)
APMP Key comparison report of reference air kerma rate for HDR 192 Ir brachytherapy sources (BIPM KCDB: APMP.RI(I)-K8)
Main text: The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K8 key comparison of the reference air kerma rate for high-dose-rate (HDR) 192 Ir brachytherapy sources between 2016 and 2018. Eight laboratories, including seven national metrology institutes (NMIs), took part in the comparison. Two commercial well-type chambers were used as transfer instruments and circulated among the participants. The results showed that the maximum difference between the participants and the BIPM, evaluated using the comparison data of the linking laboratories NMIJ and NRC, was less than 4%. The degrees of equivalence for the participants were calculated, so that results for the six non-linking laboratories may be included in the Key Comparison Database (KCDB). To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (1A)
APMP Key comparison report of reference air kerma rate for HDR 192 Ir brachytherapy sources (BIPM KCDB: APMP.RI(I)-K8)
Main text: The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K8 key comparison of the reference air kerma rate for high-dose-rate (HDR) 192 Ir brachytherapy sources between 2016 and 2018. Eight laboratories, including seven national metrology institutes (NMIs), took part in the comparison. Two commercial well-type chambers were used as transfer instruments and circulated among the participants. The results showed that the maximum difference between the participants and the BIPM, evaluated using the comparison data of the linking laboratories NMIJ and NRC, was less than 4%. The degrees of equivalence for the participants were calculated, so that results for the six non-linking laboratories may be included in the Key Comparison Database (KCDB). To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCRI, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 15 April 1997
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 81 (8) , 3842-3844
Process optimization studies of high performance recordable minidiscs
In this study, the effect of process parameters on magnetic and recording properties of MiniDiscs is reported. Processes have been tailored to optimize the recording performance of MiniDiscs, such as carrier-to-noise ratio (CNR) at low magnetic fields, recording power margin, and recording power threshold. At higher deposition pressures or lower deposition rates of TbFeCoCr, the external bias field sensitivity of the carrier becomes worse but the noise at high bias fields (>200 Oe) decreases, resulting in improved CNR at high bias fields. Disks with TbFeCoCr sputtered at low pressure or high deposition rates produce a high error rate at high recording power (>4.5 mW), due to jitter noise caused by interference of neighboring magnetic domains. The power margin of the disks is strongly affected by the pressure and deposition rate of TbFeCoCr. When the Curie temperature of the TbFeCoCr layer is lowered by 30 °C (alloy change), the power margin decreases significantly and CNR is decreased by ∼2 dB because of low Kerr rotation. CNR values well above 49.5 dB are easily achieved on MiniDiscs with optimized TbFeCoCr and SiN layers.
- 15 April 1997
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 81 (8) , 3842-3844
Process optimization studies of high performance recordable minidiscs
In this study, the effect of process parameters on magnetic and recording properties of MiniDiscs is reported. Processes have been tailored to optimize the recording performance of MiniDiscs, such as carrier-to-noise ratio (CNR) at low magnetic fields, recording power margin, and recording power threshold. At higher deposition pressures or lower deposition rates of TbFeCoCr, the external bias field sensitivity of the carrier becomes worse but the noise at high bias fields (>200 Oe) decreases, resulting in improved CNR at high bias fields. Disks with TbFeCoCr sputtered at low pressure or high deposition rates produce a high error rate at high recording power (>4.5 mW), due to jitter noise caused by interference of neighboring magnetic domains. The power margin of the disks is strongly affected by the pressure and deposition rate of TbFeCoCr. When the Curie temperature of the TbFeCoCr layer is lowered by 30 °C (alloy change), the power margin decreases significantly and CNR is decreased by ∼2 dB because of low Kerr rotation. CNR values well above 49.5 dB are easily achieved on MiniDiscs with optimized TbFeCoCr and SiN layers.
- 13 September 1993
- Published by AIP Publishing in Applied Physics Letters
- Vol. 63 (11) , 1576-1578
a-axis oriented epitaxial YBa2Cu3O7−y/PrBa2Cu3−xNbxO7−z multistructures
Using the pulsed laser deposition technique, we have successfully prepared a‐axis oriented PrBa2Cu3−xNbxO7−z (PBCNO)(x=0–1.5) films and YBa2Cu3O7−x (YBCO)/PBCNO heterorepitaxial multilayer structures. For the PBCNO films, the resistivity showed semiconducting behavior at all Nb substitution levels investigated. The resistivity increased with increasing Nb content, reaching a value of 104 Ω cm at 100 K for a 300‐Å‐thick film with x=1.0. Using (100)SrTiO3 (STO) as a substrate, the following multilayer structures were successfully formed: (100)PBCNO(x=1.0)/(100)YBCO/(100)PBCO//STO, (001) YBCO/(100)PBCNO(x=1.0)/(100)PBCO//STO, and (100)YBCO/(100)PBCO/(100)PBCNO(x=1.0)/(100)PBCO//STO. The bottom and top YBCO layers in the (100)YBCO/(100)PBCO/(100)PBCNO/(100)PBCO/(100)YBCO//STO structure showed superconducting transition temperatures (zero resistance) of 82 and 83 K, respectively. The interlayer resistivity of the 200‐Å‐thick PBCNO(x=1) interlayer was as high as 105 Ω cm at 30 K.
- 13 September 1993
- Published by AIP Publishing in Applied Physics Letters
- Vol. 63 (11) , 1576-1578
a-axis oriented epitaxial YBa2Cu3O7−y/PrBa2Cu3−xNbxO7−z multistructures
Using the pulsed laser deposition technique, we have successfully prepared a‐axis oriented PrBa2Cu3−xNbxO7−z (PBCNO)(x=0–1.5) films and YBa2Cu3O7−x (YBCO)/PBCNO heterorepitaxial multilayer structures. For the PBCNO films, the resistivity showed semiconducting behavior at all Nb substitution levels investigated. The resistivity increased with increasing Nb content, reaching a value of 104 Ω cm at 100 K for a 300‐Å‐thick film with x=1.0. Using (100)SrTiO3 (STO) as a substrate, the following multilayer structures were successfully formed: (100)PBCNO(x=1.0)/(100)YBCO/(100)PBCO//STO, (001) YBCO/(100)PBCNO(x=1.0)/(100)PBCO//STO, and (100)YBCO/(100)PBCO/(100)PBCNO(x=1.0)/(100)PBCO//STO. The bottom and top YBCO layers in the (100)YBCO/(100)PBCO/(100)PBCNO/(100)PBCO/(100)YBCO//STO structure showed superconducting transition temperatures (zero resistance) of 82 and 83 K, respectively. The interlayer resistivity of the 200‐Å‐thick PBCNO(x=1) interlayer was as high as 105 Ω cm at 30 K.