Abstract
Open-phase fault and current sensor fault are common in multiphase permanent magnet synchronous motor (PMSM) systems. However, the characteristics of the two fault types are too similar to be distinguished, resulting in misdiagnosis and thereby misleading implementation of fault-tolerant control. In this paper, a locate-then-identify method is proposed to diagnose both open-phase fault and current sensor fault in the dual three-phase PMSM system. First, each phase current is decomposed by vector space decomposition transformation into fundamental, harmonic, and zero-sequence components. The ratio of these components enables fault location through the common characteristics of open-phase fault and current sensor fault. Subsequently, the asymmetric high-frequency voltage is injected into the dual three-phase PMSM system according to the fault location. Then, the fault type is identified based on the distinct responses to asymmetric high-frequency excitation under open-phase and current sensor faults. The proposed locate-then-identify method not only reduces the impact of real-time high-frequency injection on system control performance but also eliminates the need for additional voltage sensors. Finally, the effectiveness of the proposed fault diagnosis method is verified by experiments.
Funding Information
  • National Natural Science Foundation of China (52025073)
  • National Natural Science Foundation of China (52507060)

This publication has 33 references indexed in Scilit: