Yuxuan Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yuxuan Du has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Wenxiang Zhao
Nanjing Institute of Technology
10 shared publications - Tao Tao
Jiangsu University
6 shared publications - Jinghua Ji
Jiangsu University
5 shared publications Zongwang Li
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China
3 shared publications- Linsen Huang
School of Electrical and Information Engineering, Jiangsu University, Zhenjiang, China
2 shared publications Tao Tao
School of Electrical and Information Engineering, National Center for International Research on Structural Health Management of Critical Components, Jiangsu University, Zhenjiang, China
2 shared publications
Latest Publications
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 12968-12980
Phase Current Reconstruction for Dual Three-Phase PMSM With Hybrid Zero-Vector Modulation Strategy
Phase current information is critical for dual three-phase permanent magnet synchronous motor (DTP-PMSM) drive, but conventional multi-sensor solutions increase system bulk and cost. This paper proposed a current reconstruction method for DTP-PMSM with a hybrid zero-vector modulation strategy, in which only two current sensors are adopted. First, a low-complexity placement scheme for the two current sensors is proposed, enabling the acquisition of four-phase currents with them. Second, a novel hybrid zero-vector modulation strategy is employed to facilitate the reconstruction of six-phase currents within a single pulse-width modulation cycle. The proposed modulation strategy can not only achieve accurate current reconstruction in the low modulation region but also eliminate dead zones at sector boundaries. Also, the current sampling delay and the residual dead zone of the current reconstruction are analyzed. Experimental results validate the effectiveness of the proposed control strategy.
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (8) , 12968-12980
Phase Current Reconstruction for Dual Three-Phase PMSM With Hybrid Zero-Vector Modulation Strategy
Phase current information is critical for dual three-phase permanent magnet synchronous motor (DTP-PMSM) drive, but conventional multi-sensor solutions increase system bulk and cost. This paper proposed a current reconstruction method for DTP-PMSM with a hybrid zero-vector modulation strategy, in which only two current sensors are adopted. First, a low-complexity placement scheme for the two current sensors is proposed, enabling the acquisition of four-phase currents with them. Second, a novel hybrid zero-vector modulation strategy is employed to facilitate the reconstruction of six-phase currents within a single pulse-width modulation cycle. The proposed modulation strategy can not only achieve accurate current reconstruction in the low modulation region but also eliminate dead zones at sector boundaries. Also, the current sampling delay and the residual dead zone of the current reconstruction are analyzed. Experimental results validate the effectiveness of the proposed control strategy.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3863-3873
A Locate-Then-Identify Diagnosis for Open-Phase and Current Sensor Faults of DTP-PMSM System With Asymmetric High-Frequency Injection
Open-phase fault and current sensor fault are common in multiphase permanent magnet synchronous motor (PMSM) systems. However, the characteristics of the two fault types are too similar to be distinguished, resulting in misdiagnosis and thereby misleading implementation of fault-tolerant control. In this paper, a locate-then-identify method is proposed to diagnose both open-phase fault and current sensor fault in the dual three-phase PMSM system. First, each phase current is decomposed by vector space decomposition transformation into fundamental, harmonic, and zero-sequence components. The ratio of these components enables fault location through the common characteristics of open-phase fault and current sensor fault. Subsequently, the asymmetric high-frequency voltage is injected into the dual three-phase PMSM system according to the fault location. Then, the fault type is identified based on the distinct responses to asymmetric high-frequency excitation under open-phase and current sensor faults. The proposed locate-then-identify method not only reduces the impact of real-time high-frequency injection on system control performance but also eliminates the need for additional voltage sensors. Finally, the effectiveness of the proposed fault diagnosis method is verified by experiments.
- 10 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3863-3873
A Locate-Then-Identify Diagnosis for Open-Phase and Current Sensor Faults of DTP-PMSM System With Asymmetric High-Frequency Injection
Open-phase fault and current sensor fault are common in multiphase permanent magnet synchronous motor (PMSM) systems. However, the characteristics of the two fault types are too similar to be distinguished, resulting in misdiagnosis and thereby misleading implementation of fault-tolerant control. In this paper, a locate-then-identify method is proposed to diagnose both open-phase fault and current sensor fault in the dual three-phase PMSM system. First, each phase current is decomposed by vector space decomposition transformation into fundamental, harmonic, and zero-sequence components. The ratio of these components enables fault location through the common characteristics of open-phase fault and current sensor fault. Subsequently, the asymmetric high-frequency voltage is injected into the dual three-phase PMSM system according to the fault location. Then, the fault type is identified based on the distinct responses to asymmetric high-frequency excitation under open-phase and current sensor faults. The proposed locate-then-identify method not only reduces the impact of real-time high-frequency injection on system control performance but also eliminates the need for additional voltage sensors. Finally, the effectiveness of the proposed fault diagnosis method is verified by experiments.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (3) , 3842-3854
Postfault Sensorless Control of Three-Phase SPMSM Based on Unified Model of Diode-Through Residual Current Under Single-Phase IGBT Open-Circuit Fault
Sensorless control under open-circuit faults is challenging for classic three-phase half-bridge motor drives. This paper proposes a method that exploits the correlation between back-electromagnetic force (back-EMF) and diode-through residual current in the IGBT open-circuit phase. First, the residual current model is developed, followed by a sampling strategy that unifies the model under different speeds. Using this unified model, a phase back-EMF observer is designed, enabling accurate postfault estimation of rotor speed and position. Experimental validation demonstrates the effectiveness of the proposed method, achieving an estimation error of 0.3 radians under steady-state conditions and 0.5 radians during acceleration and deceleration.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (3) , 3842-3854
Postfault Sensorless Control of Three-Phase SPMSM Based on Unified Model of Diode-Through Residual Current Under Single-Phase IGBT Open-Circuit Fault
Sensorless control under open-circuit faults is challenging for classic three-phase half-bridge motor drives. This paper proposes a method that exploits the correlation between back-electromagnetic force (back-EMF) and diode-through residual current in the IGBT open-circuit phase. First, the residual current model is developed, followed by a sampling strategy that unifies the model under different speeds. Using this unified model, a phase back-EMF observer is designed, enabling accurate postfault estimation of rotor speed and position. Experimental validation demonstrates the effectiveness of the proposed method, achieving an estimation error of 0.3 radians under steady-state conditions and 0.5 radians during acceleration and deceleration.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (4) , 7971-7983
Quasi-Fault-Tolerant Control for Open-End Winding Five-Phase PMSM With High-Resistance Connection Failure Using Time-Variant Transform Techniques
In the field of electrified ship propulsion, system reliability is paramount due to the essential nature of continuous operation. Multiphase permanent magnet synchronous motors (PMSMs) are vital for their high efficiency and power density. Nonetheless, system reliability may be jeopardized by high-resistance connections (HRCs) failure, which can cause performance to deteriorate and may lead to open-circuit failures. To address the existing HRC fault-tolerant control (FTC) failure to achieve the same performance during normal and FTC operations, this study introduces a quasi-fault-tolerant control (QFTC) strategy without needing algorithmic switching when HRC failure occurs. The proposed QFTC strategy utilizes a time-variant transformation technique to dynamically regulate the current reference output, compensating for resistance variations encountered during HRC failure. The QFTC strategy proactively manages electrical parameters when HRC failure occurs, thereby reducing power losses, preserving torque output, and enhancing the reliability of the propulsion system. Finally, the effectiveness of the proposed QFTC strategy is verified through experimental validation. The experimental results show that the proposed QFTC strategy increases drive system efficiency by up to 3.36% compared to the one without FTC.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (4) , 7971-7983
Quasi-Fault-Tolerant Control for Open-End Winding Five-Phase PMSM With High-Resistance Connection Failure Using Time-Variant Transform Techniques
In the field of electrified ship propulsion, system reliability is paramount due to the essential nature of continuous operation. Multiphase permanent magnet synchronous motors (PMSMs) are vital for their high efficiency and power density. Nonetheless, system reliability may be jeopardized by high-resistance connections (HRCs) failure, which can cause performance to deteriorate and may lead to open-circuit failures. To address the existing HRC fault-tolerant control (FTC) failure to achieve the same performance during normal and FTC operations, this study introduces a quasi-fault-tolerant control (QFTC) strategy without needing algorithmic switching when HRC failure occurs. The proposed QFTC strategy utilizes a time-variant transformation technique to dynamically regulate the current reference output, compensating for resistance variations encountered during HRC failure. The QFTC strategy proactively manages electrical parameters when HRC failure occurs, thereby reducing power losses, preserving torque output, and enhancing the reliability of the propulsion system. Finally, the effectiveness of the proposed QFTC strategy is verified through experimental validation. The experimental results show that the proposed QFTC strategy increases drive system efficiency by up to 3.36% compared to the one without FTC.
- 2 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 13597-13612
Inverter Reconstruction Approach for Open-End Winding Five-Phase PMSM With Pattern-Based Vector Synthesis and Hybrid SVPWM Modulation
Due to the overloading, vibration, and harsh conditions, switching transistors in open-end winding five-phase permanent magnet synchronous motors (OWFP-PMSMs) drives are more vulnerable to failure. Addressing the increased post-fault current in existing fault-tolerant control (FTC) methods, this article presents an inverter reconstruction approach for the OWFP-PMSM. When transistor failure occurs, the inverter reconstruction approach is achieved by connecting the winding to the midpoint of the bus capacitor. A pattern-based virtual voltage vector synthesis method is introduced to achieve voltage vectors that existing modulation methods cannot synthesize. Then, a hybrid SVPWM strategy is adopted to achieve dual inverter modulation and capacitor voltage compensation in the OWFP-PMSM drive system. The innovation of this article not only enhances the FTC capability of the OWFP-PMSM drive system but also maintains good postfault steady-state performance. Moreover, the amplitude of the postfault phase current resembles that observed during healthy operation, which is a significant reduction compared to the established FTC strategy. Through simulations and experiments, the effectiveness of the proposed method is demonstrated. The results show that the phase current amplitude is reduced by up to 26.5% during steady-state operation compared to the existing method.
- 2 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (10) , 13597-13612
Inverter Reconstruction Approach for Open-End Winding Five-Phase PMSM With Pattern-Based Vector Synthesis and Hybrid SVPWM Modulation
Due to the overloading, vibration, and harsh conditions, switching transistors in open-end winding five-phase permanent magnet synchronous motors (OWFP-PMSMs) drives are more vulnerable to failure. Addressing the increased post-fault current in existing fault-tolerant control (FTC) methods, this article presents an inverter reconstruction approach for the OWFP-PMSM. When transistor failure occurs, the inverter reconstruction approach is achieved by connecting the winding to the midpoint of the bus capacitor. A pattern-based virtual voltage vector synthesis method is introduced to achieve voltage vectors that existing modulation methods cannot synthesize. Then, a hybrid SVPWM strategy is adopted to achieve dual inverter modulation and capacitor voltage compensation in the OWFP-PMSM drive system. The innovation of this article not only enhances the FTC capability of the OWFP-PMSM drive system but also maintains good postfault steady-state performance. Moreover, the amplitude of the postfault phase current resembles that observed during healthy operation, which is a significant reduction compared to the established FTC strategy. Through simulations and experiments, the effectiveness of the proposed method is demonstrated. The results show that the phase current amplitude is reduced by up to 26.5% during steady-state operation compared to the existing method.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 10116-10127
Zero-Sequence Current Suppression Strategy for Five-Phase OW-PMSM With Reduced Common-Mode Voltage and Inverter Losses
Zero-sequence current (ZSC) exists in five-phase open-winding permanent magnet synchronous motors (FPOW-PMSMs) with a common dc bus, resulting in harmonic current and system losses. Besides, the use of the dual-inverter increases inverter losses and induces a high-frequency common-mode voltage (CMV), damaging the bearing. This article proposes a novel ZSC suppression method for the FPOW-PMSM, which can reduce the inverter losses while decreasing the CMV. First, the average zero-sequence voltage equal to zero is considered a restriction to calculate the duration time of basis vectors. Five active vectors are selected to synthesize the reference voltage vector in each sector. Then, benefiting from abundant switching states redundancy, a novel switching states combination with minimum switching actions is proposed to reduce the CMV and inverter losses. Furthermore, the modulation range of the proposed modulation method is analyzed, indicating that the proposed method achieves considerable dc-bus voltage utilization. Finally, the experimental results verify the effectiveness of the proposed method.
- 22 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (8) , 10116-10127
Zero-Sequence Current Suppression Strategy for Five-Phase OW-PMSM With Reduced Common-Mode Voltage and Inverter Losses
Zero-sequence current (ZSC) exists in five-phase open-winding permanent magnet synchronous motors (FPOW-PMSMs) with a common dc bus, resulting in harmonic current and system losses. Besides, the use of the dual-inverter increases inverter losses and induces a high-frequency common-mode voltage (CMV), damaging the bearing. This article proposes a novel ZSC suppression method for the FPOW-PMSM, which can reduce the inverter losses while decreasing the CMV. First, the average zero-sequence voltage equal to zero is considered a restriction to calculate the duration time of basis vectors. Five active vectors are selected to synthesize the reference voltage vector in each sector. Then, benefiting from abundant switching states redundancy, a novel switching states combination with minimum switching actions is proposed to reduce the CMV and inverter losses. Furthermore, the modulation range of the proposed modulation method is analyzed, indicating that the proposed method achieves considerable dc-bus voltage utilization. Finally, the experimental results verify the effectiveness of the proposed method.
- 17 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 2211-2222
Enhanced Fault Tolerance of Dual Three-Phase Permanent Magnet Motor With Three-Redundancy Control
This article proposes a novel three-redundancy control for the dual three-phase permanent magnet (DTP-PM) motor to enhance the open-phase fault tolerance. Three redundancies can be operated individually or synergistically. Hence, the faulty redundancy can be disconnected from the system to address the open-phase fault. The fault tolerance can be significantly enhanced. Primarily, the structure of the DTP-PM motor is analyzed. Six phases of the DTP-PM motor are separated into three sets of orthogonal phases and considered three two-phase motors. Therefore, three redundancies can be established. Since orthogonal phases provide a balanced structure, the magnetomotive force of each redundancy can be well controlled. Then, a DTP-PM motor control system with three redundancies is established, and a potential topology for the proposed strategy is also illustrated. Furthermore, the basic voltage vectors for each redundancy are investigated. The reference voltage vectors can be modulated expediently. Finally, some simulations and experiments are carried out, validating the feasibility and effectiveness of the proposed strategy.
- 17 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 38 (3) , 2211-2222
Enhanced Fault Tolerance of Dual Three-Phase Permanent Magnet Motor With Three-Redundancy Control
This article proposes a novel three-redundancy control for the dual three-phase permanent magnet (DTP-PM) motor to enhance the open-phase fault tolerance. Three redundancies can be operated individually or synergistically. Hence, the faulty redundancy can be disconnected from the system to address the open-phase fault. The fault tolerance can be significantly enhanced. Primarily, the structure of the DTP-PM motor is analyzed. Six phases of the DTP-PM motor are separated into three sets of orthogonal phases and considered three two-phase motors. Therefore, three redundancies can be established. Since orthogonal phases provide a balanced structure, the magnetomotive force of each redundancy can be well controlled. Then, a DTP-PM motor control system with three redundancies is established, and a potential topology for the proposed strategy is also illustrated. Furthermore, the basic voltage vectors for each redundancy are investigated. The reference voltage vectors can be modulated expediently. Finally, some simulations and experiments are carried out, validating the feasibility and effectiveness of the proposed strategy.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 11085-11097
Remedial Direct Torque Control for Dual Three-Phase Permanent-Magnet Motor With Harmonic Torque Suppression
This article proposes a novel remedial direct torque control (RDTC) for the postfault operation of the dual three-phase permanent-magnet (DTP-PM) motor. The DTP-PM motor is configured as a two-neutral points model and fed by an eight-leg voltage source inverter. Also, the harmonic torque induced by the third harmonic back electromotive force and zero-sequence currents is considered at the postfault operation. First, the switching tables for different fault conditions are pre-established. The proposed strategy can be applied to different postfault operations with one phase open by replacing the switching table simply. At the normal operation, the redundant auxiliary legs are disabled. So, the proposed eight-leg voltage inverter is the same as the conventional six-leg one. At the postfault operation, the auxiliary leg in the faulty three-phase windings provides an additional control degree of freedom. Hence, the fault-tolerant capability of the DTP-PM motor with two neutral points can be enhanced. Also, the proposed strategy compensates for the harmonic torque by modifying the reference torque. Based on the proposed RDTC, the postfault operational performance can be significantly improved. Finally, the simulations and experiments are conducted to validate the feasibility of the proposed strategy.
- 22 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 11085-11097
Remedial Direct Torque Control for Dual Three-Phase Permanent-Magnet Motor With Harmonic Torque Suppression
This article proposes a novel remedial direct torque control (RDTC) for the postfault operation of the dual three-phase permanent-magnet (DTP-PM) motor. The DTP-PM motor is configured as a two-neutral points model and fed by an eight-leg voltage source inverter. Also, the harmonic torque induced by the third harmonic back electromotive force and zero-sequence currents is considered at the postfault operation. First, the switching tables for different fault conditions are pre-established. The proposed strategy can be applied to different postfault operations with one phase open by replacing the switching table simply. At the normal operation, the redundant auxiliary legs are disabled. So, the proposed eight-leg voltage inverter is the same as the conventional six-leg one. At the postfault operation, the auxiliary leg in the faulty three-phase windings provides an additional control degree of freedom. Hence, the fault-tolerant capability of the DTP-PM motor with two neutral points can be enhanced. Also, the proposed strategy compensates for the harmonic torque by modifying the reference torque. Based on the proposed RDTC, the postfault operational performance can be significantly improved. Finally, the simulations and experiments are conducted to validate the feasibility of the proposed strategy.