Detection of Endoleaks Following Thoracic and Abdominal Aortic Endovascular Aortic Repair—: A Comparison of Standard and Dynamic 4D-Computed Tomography Angiography
- 18 May 2022
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 30 (5) , 739-745
Abstract
Purpose: Endoleaks are a common complication after endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR). The detection and correct classification of endoleaks is essential for the further treatment of affected patients. However, standard computed tomography angiography (CTA) provides no hemodynamic information on endoleaks, which can result in misclassification in complex cases. The aim of this study was to compare standard CTA (sCTA) with dynamic, dual-energy CTA (dCTA) for detection and classification of endoleaks following EVAR or TEVAR. Materials and Methods: This retrospective evaluation compared 69 sCTA diagnostic examinations performed on 50 different patients with 89 dCTA diagnostic examinations performed on 69 different patients. Results: In total, 15.9% of sCTA examinations and 49.4% of dCTA examinations led to the detection of endoleaks. With sCTA, 20.0% of patients were diagnosed with endoleaks, while with dCTA, 37.7% of patients were diagnosed with endoleaks. With sCTA, mainly Type 1 endoleaks were detected, whereas, with dCTA, the types of detected endoleaks were more evenly distributed. In comparison with the literature, the frequencies of endoleak types detected with dCTA better reflect the natural distribution than the frequencies detected with standard CTA. Conclusion: Based on the retrospective comparative evaluation, dCTA could pose a valuable supplementary diagnostic tool resulting in a more accurate and realistic detection and classification of suspected endoleaks.Keywords
This publication has 30 references indexed in Scilit:
- Early experience with off-the-shelf endografts using a zone 0 proximal landing site to treat the ascending aorta and archThe Journal of Thoracic and Cardiovascular Surgery, 2014
- Time Efficiency and Diagnostic Accuracy of New Automated Myocardial Perfusion Analysis Software in 320-Row CT Cardiac ImagingKorean Journal of Radiology, 2013
- Comparison of Long-term Survival After Open vs Endovascular Repair of Intact Abdominal Aortic Aneurysm Among Medicare BeneficiariesJAMA, 2012
- Paradigm shifts in the treatment of abdominal aortic aneurysm: Trends in 721 patients between 1996 and 2008Journal of Vascular Surgery, 2010
- Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic AccuracyCirculation, 2009
- Complications after Endovascular Aneurysm RepairSeminars in Interventional Radiology, 2009
- Diagnostic Performance of Coronary Angiography by 64-Row CTNew England Journal of Medicine, 2008
- Aneurysm Sac Pressure after EVAR: The Role of EndoleakEuropean Journal of Vascular and Endovascular Surgery, 2007
- Endoleaks after endovascular repair of thoracic aortic aneurysmsJournal of Vascular Surgery, 2006
- Six-Year Experience With Talent Stent-Graft Repair of Abdominal Aortic AneurysmsJournal of Endovascular Therapy, 2005