Benjamin Valentin Becker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Benjamin Valentin Becker has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
Matthias Port
Bundeswehr Institute of Radiobiology Affiliated to Ulm University, Munich, Germany
6 shared publications- Reinhard Ullmann
Bundeswehr Institute of Radiobiology Affiliated to Ulm University, Munich, Germany
6 shared publications - Hanns Leonhard Kaatsch
Department of Radiology and Neuroradiology, Bundeswehr Central Hospital, Rübenacher Straße 170, 56072 Koblenz, Germany
5 shared publications - Kai Nestler
Zentrum für Luft- und Raumfahrtmedizin der Luftwaffe, Deutschland
5 shared publications Marc A. Brockmann
Department of Neuroradiology, University Medical Center Mainz, Mainz, Germany
5 shared publications- Matthias Port
Bundeswehr Institute of Radiobiology
5 shared publications
Latest Publications
- Open Access
- 29 March 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (7) , 3185
Routine CT Diagnostics Cause Dose-Dependent Gene Expression Changes in Peripheral Blood Cells
The increasing use of computed tomography (CT) has led to a rise in cumulative radiation dose due to medical imaging, raising concerns about potential long-term adverse effects. Large-scale epidemiological studies indicate a higher tumor incidence associated with CT examinations, but the underlying biological mechanisms remain largely unexplained. To gain further insights into the cellular response triggered by routine CT diagnostics, we investigated CT-induced changes of gene expression in peripheral blood cells using whole transcriptome sequencing. RNA was isolated from peripheral blood cells of 40 male patients with asymptomatic microhematuria, sampled before and after multi-phase abdominal CT (CTDIvol: 3.75–26.95 mGy, median: 6.55 mGy). On average, 22.11 million sequence reads (SD 5.71) per sample were generated to identify differentially expressed genes 6 h post-exposure by means of DESeq2. To assess the dose dependency of CT-induced effects, we additionally divided samples into three categories: low exposure (≤6.55 mGy, n = 20), medium exposure (>6.55 mGy and EDA2R, AEN, FDXR, DDB2, PHLDA3, and MIR34AHG; padj < 0.1). These genes share several functional commonalities, including regulation by TP53 and involvement in the DNA damage response. The biological pathways highlighted by Gene Set Enrichment Analysis (GSEA) suggest a dose-dependent increase of cellular damage and metabolic particularities in the low-exposure subset, which may be related to a potential adaptive cellular response to low-dose irradiation. Irrespective of applied dose, AEN emerged as the most robust biomarker for CT exposure among all genes. Routine abdominal CT scans cause dose-dependent gene deregulation in association with DNA damage in peripheral blood cells after in vivo exposure. Regarding risk assessment of CT, our results support the commonly applied “As Low–As –Reasonably Achievable (ALARA)” principle. Evidence of additional gene expression changes associated with metabolic processes indicates a rather complex molecular response beyond DNA damage after CT exposure, and emphasizes the need for further targeted investigations.
- 29 March 2025
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 26 (7) , 3185
Open AccessRoutine CT Diagnostics Cause Dose-Dependent Gene Expression Changes in Peripheral Blood Cells
The increasing use of computed tomography (CT) has led to a rise in cumulative radiation dose due to medical imaging, raising concerns about potential long-term adverse effects. Large-scale epidemiological studies indicate a higher tumor incidence associated with CT examinations, but the underlying biological mechanisms remain largely unexplained. To gain further insights into the cellular response triggered by routine CT diagnostics, we investigated CT-induced changes of gene expression in peripheral blood cells using whole transcriptome sequencing. RNA was isolated from peripheral blood cells of 40 male patients with asymptomatic microhematuria, sampled before and after multi-phase abdominal CT (CTDIvol: 3.75–26.95 mGy, median: 6.55 mGy). On average, 22.11 million sequence reads (SD 5.71) per sample were generated to identify differentially expressed genes 6 h post-exposure by means of DESeq2. To assess the dose dependency of CT-induced effects, we additionally divided samples into three categories: low exposure (≤6.55 mGy, n = 20), medium exposure (>6.55 mGy and EDA2R, AEN, FDXR, DDB2, PHLDA3, and MIR34AHG; padj < 0.1). These genes share several functional commonalities, including regulation by TP53 and involvement in the DNA damage response. The biological pathways highlighted by Gene Set Enrichment Analysis (GSEA) suggest a dose-dependent increase of cellular damage and metabolic particularities in the low-exposure subset, which may be related to a potential adaptive cellular response to low-dose irradiation. Irrespective of applied dose, AEN emerged as the most robust biomarker for CT exposure among all genes. Routine abdominal CT scans cause dose-dependent gene deregulation in association with DNA damage in peripheral blood cells after in vivo exposure. Regarding risk assessment of CT, our results support the commonly applied “As Low–As –Reasonably Achievable (ALARA)” principle. Evidence of additional gene expression changes associated with metabolic processes indicates a rather complex molecular response beyond DNA damage after CT exposure, and emphasizes the need for further targeted investigations.
- Open Access
The Immunomodulatory Effect of Different FLT3 Inhibitors on Dendritic Cells
Background: FMS-like tyrosine kinase 3 (FLT3) mutations or internal tandem duplication occur in 30% of acute myeloid leukemia (AML) cases. In these cases, FLT3 inhibitors (FLT3i) are approved for induction treatment and relapse. Allogeneic hematopoietic stem cell transplantation (alloHSCT) remains the recommended post-induction therapy for suitable patients. However, the role of FLT3i therapy after alloHSCT remains unclear. Therefore, we investigated the three currently available FLT3i, gilteritinib, midostaurin, and quizartinib, in terms of their immunosuppressive effect on dendritic cells (DCs). DCs are professional antigen-presenting cells inducing T-cell responses to infectious stimuli. Highly activated DCs can also cause complications after alloHSCT, such as triggering Graft versus Host disease, a serious and potentially life-threatening complication after alloHSCT. Methods: To study the immunomodulatory effects on DCs, we differentiated murine and human DCs in the presence of FLT3i and performed immunophenotyping by flow cytometry and cytokine measurements and investigated gene and protein expression. Results: We detected a dose-dependent immunosuppressive effect of midostaurin, which decreased the expression of costimulatory markers like CD86, and found a reduced secretion of pro-inflammatory cytokines such as IL-12, TNFα, and IL-6. Mechanistically, we show that midostaurin inhibits TLR and TNF signaling and NFκB, PI3K, and MAPK pathways. The immunosuppressive effect of gilteritinib was less pronounced, while quizartinib did not show truncation of relevant signaling pathways. Conclusions: Our results suggest different immunosuppressive effects of these three FLT3i and may, therefore, provide an additional rationale for optimal maintenance therapy after alloHSCT of FLT3-positive AML patients to prevent infectious complications and GvHD mediated by DCs.
Open AccessThe Immunomodulatory Effect of Different FLT3 Inhibitors on Dendritic Cells
Background: FMS-like tyrosine kinase 3 (FLT3) mutations or internal tandem duplication occur in 30% of acute myeloid leukemia (AML) cases. In these cases, FLT3 inhibitors (FLT3i) are approved for induction treatment and relapse. Allogeneic hematopoietic stem cell transplantation (alloHSCT) remains the recommended post-induction therapy for suitable patients. However, the role of FLT3i therapy after alloHSCT remains unclear. Therefore, we investigated the three currently available FLT3i, gilteritinib, midostaurin, and quizartinib, in terms of their immunosuppressive effect on dendritic cells (DCs). DCs are professional antigen-presenting cells inducing T-cell responses to infectious stimuli. Highly activated DCs can also cause complications after alloHSCT, such as triggering Graft versus Host disease, a serious and potentially life-threatening complication after alloHSCT. Methods: To study the immunomodulatory effects on DCs, we differentiated murine and human DCs in the presence of FLT3i and performed immunophenotyping by flow cytometry and cytokine measurements and investigated gene and protein expression. Results: We detected a dose-dependent immunosuppressive effect of midostaurin, which decreased the expression of costimulatory markers like CD86, and found a reduced secretion of pro-inflammatory cytokines such as IL-12, TNFα, and IL-6. Mechanistically, we show that midostaurin inhibits TLR and TNF signaling and NFκB, PI3K, and MAPK pathways. The immunosuppressive effect of gilteritinib was less pronounced, while quizartinib did not show truncation of relevant signaling pathways. Conclusions: Our results suggest different immunosuppressive effects of these three FLT3i and may, therefore, provide an additional rationale for optimal maintenance therapy after alloHSCT of FLT3-positive AML patients to prevent infectious complications and GvHD mediated by DCs.
- Open Access
- 6 October 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2231
Improved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT
Objectives: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. Materials & Methods: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. Results: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (p < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (p < 0.001) except for 50 keV (p > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60–70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. Conclusions: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40–50 keV.
- 6 October 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2231
Open AccessImproved Discriminability of Severe Lung Injury and Atelectasis in Thoracic Trauma at Low keV Virtual Monoenergetic Images from Photon-Counting Detector CT
Objectives: To evaluate the value of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) for discriminability of severe lung injury and atelectasis in polytraumatized patients. Materials & Methods: Contrast-enhanced PCD-CT examinations of 20 polytraumatized patients with severe thoracic trauma were included in this retrospective study. Spectral PCD-CT data were reconstructed using a noise-optimized virtual monoenergetic imaging (VMI) algorithm with calculated VMIs ranging from 40 to 120 keV at 10 keV increments. Injury-to-atelectasis contrast-to-noise ratio (CNR) was calculated and compared at each energy level based on CT number measurements in severely injured as well as atelectatic lung areas. Three radiologists assessed subjective discriminability, noise perception, and overall image quality. Results: CT values for atelectasis decreased as photon energy increased from 40 keV to 120 keV (mean Hounsfield units (HU): 69 at 40 keV; 342 at 120 keV), whereas CT values for severe lung injury remained near-constant from 40 keV to 120 keV (mean HU: 42 at 40 keV; 44 at 120 keV) with significant differences at each keV level (p < 0.001). The optimal injury-to-atelectasis CNR was observed at 40 keV in comparison with the remaining energy levels (p < 0.001) except for 50 keV (p > 0.05). In line with this, VMIs at 40 keV were rated best regarding subjective discriminability. VMIs at 60–70 keV, however, provided the highest subjective observer parameters regarding subjective image noise as well as image quality. Conclusions: Discriminability between severely injured and atelectatic lung areas after thoracic trauma can be substantially improved by virtual monoenergetic imaging from PCD-CT with superior contrast and visual discriminability at 40–50 keV.
- Open Access
- 8 December 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (4) , 2461-2468
Initial experience on abdominal photon-counting computed tomography in clinical routine: general image quality and dose exposure
Objectives: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography. Methods: In this single-center retrospective study, 66 patients underwent photon-counting and conventional abdominal CT. Four radiologists assessed general image quality, image noise, and image artifacts. Signal-to-noise ratio and dose properties of both techniques within the clinical application were compared. An ex vivo phantom study revealed the radiobiological impact by means of DNA double-strand break foci in peripheral blood cells by enumerating γ-H2AX+53BP1 foci. Results: General image quality in accordance with the Likert scale was found superior for photon-counting CT (4.74 ± 0.46 vs. 4.25 ± 0.54; p < 0.001). Signal-to-noise ratio (p < 0.001) and also dose exposure were higher for photon-counting CT (DLP: 419.2 ± 162.2 vs. 372.3 ± 236.6 mGy*cm; p = 0.0435). CT exposure resulted in significantly increased DNA damage in comparison to sham control (p < 0.001). Investigation of the average foci per cell and radiation-induced foci numbers revealed significantly elevated numbers (p = 0.004 and p < 0.0001, respectively) after photon-counting CT. Conclusion: Photon-counting CT in abdominal examinations showed superior results regarding general image quality and signal-to-noise ratio in clinical routine. However, this seems to be traded for a significantly higher dose exposure and corresponding double-strand break frequency. Optimization of standard protocols in further clinical applications is required to find a compromise regarding picture quality and dose exposure. Key Points: • Photon-counting computed tomography promises to enhance the diagnostic potential of medical imaging in clinical routine. • Retrospective single-center study showed superior general image quality accompanied by higher dose exposure in initial abdominal PCCT protocols compared to state-of-the-art conventional CT. • A simultaneous ex vivo phantom study revealed correspondingly increased frequencies of DNA double-strand breaks after PCCT.
- 8 December 2022
- Published by Springer Nature in European Radiology
- Vol. 33 (4) , 2461-2468
Open AccessInitial experience on abdominal photon-counting computed tomography in clinical routine: general image quality and dose exposure
Objectives: Photon-counting computed tomography has lately found its way into clinical routine. The new technique could offer substantial improvements regarding general image quality, image noise, and radiation dose reduction. This study evaluated the first abdominal examinations in clinical routine and compared the results to conventional computed tomography. Methods: In this single-center retrospective study, 66 patients underwent photon-counting and conventional abdominal CT. Four radiologists assessed general image quality, image noise, and image artifacts. Signal-to-noise ratio and dose properties of both techniques within the clinical application were compared. An ex vivo phantom study revealed the radiobiological impact by means of DNA double-strand break foci in peripheral blood cells by enumerating γ-H2AX+53BP1 foci. Results: General image quality in accordance with the Likert scale was found superior for photon-counting CT (4.74 ± 0.46 vs. 4.25 ± 0.54; p < 0.001). Signal-to-noise ratio (p < 0.001) and also dose exposure were higher for photon-counting CT (DLP: 419.2 ± 162.2 vs. 372.3 ± 236.6 mGy*cm; p = 0.0435). CT exposure resulted in significantly increased DNA damage in comparison to sham control (p < 0.001). Investigation of the average foci per cell and radiation-induced foci numbers revealed significantly elevated numbers (p = 0.004 and p < 0.0001, respectively) after photon-counting CT. Conclusion: Photon-counting CT in abdominal examinations showed superior results regarding general image quality and signal-to-noise ratio in clinical routine. However, this seems to be traded for a significantly higher dose exposure and corresponding double-strand break frequency. Optimization of standard protocols in further clinical applications is required to find a compromise regarding picture quality and dose exposure. Key Points: • Photon-counting computed tomography promises to enhance the diagnostic potential of medical imaging in clinical routine. • Retrospective single-center study showed superior general image quality accompanied by higher dose exposure in initial abdominal PCCT protocols compared to state-of-the-art conventional CT. • A simultaneous ex vivo phantom study revealed correspondingly increased frequencies of DNA double-strand breaks after PCCT.
- Open Access
- 21 June 2022
- Published by MDPI AG in Tomography
- Vol. 8 (4) , 1642-1648
Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, the photon-counting detector (PCD-CT) is a new emerging technology with the potential to eliminate these problems. This study evaluated the performance of virtual monoenergetic (VME) EID-CT images versus PCD-CT in CI imaging. In this cadaveric study, two temporal bone specimens with implanted CIs were scanned with EID-CT and PCD-CT. The images were assessed according to the visibility of interelectrode wire, size of electrode contact, and diameter of halo artifacts. The visibility of interelectrode wire sections was significantly higher when reviewing PCD-CT images. The difference in diameter measurements for electrode contacts between the two CT scanner modalities showed that the PCD-CT technology generally led to significantly larger diameter readings. The larger measurements were closer to the manufacturer’s specifications for the CI electrode. The size of halo artifacts surrounding the electrode contacts did not differ significantly between the two imaging modalities. PCT-CT imaging is a promising technology for CI imaging with improved spatial resolution and better visibility of small structures than conventional EID-CT.
- 21 June 2022
- Published by MDPI AG in Tomography
- Vol. 8 (4) , 1642-1648
Open AccessPhoton-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, the photon-counting detector (PCD-CT) is a new emerging technology with the potential to eliminate these problems. This study evaluated the performance of virtual monoenergetic (VME) EID-CT images versus PCD-CT in CI imaging. In this cadaveric study, two temporal bone specimens with implanted CIs were scanned with EID-CT and PCD-CT. The images were assessed according to the visibility of interelectrode wire, size of electrode contact, and diameter of halo artifacts. The visibility of interelectrode wire sections was significantly higher when reviewing PCD-CT images. The difference in diameter measurements for electrode contacts between the two CT scanner modalities showed that the PCD-CT technology generally led to significantly larger diameter readings. The larger measurements were closer to the manufacturer’s specifications for the CI electrode. The size of halo artifacts surrounding the electrode contacts did not differ significantly between the two imaging modalities. PCT-CT imaging is a promising technology for CI imaging with improved spatial resolution and better visibility of small structures than conventional EID-CT.
- 18 May 2022
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 30 (5) , 739-745
Detection of Endoleaks Following Thoracic and Abdominal Aortic Endovascular Aortic Repair—: A Comparison of Standard and Dynamic 4D-Computed Tomography Angiography
Purpose: Endoleaks are a common complication after endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR). The detection and correct classification of endoleaks is essential for the further treatment of affected patients. However, standard computed tomography angiography (CTA) provides no hemodynamic information on endoleaks, which can result in misclassification in complex cases. The aim of this study was to compare standard CTA (sCTA) with dynamic, dual-energy CTA (dCTA) for detection and classification of endoleaks following EVAR or TEVAR. Materials and Methods: This retrospective evaluation compared 69 sCTA diagnostic examinations performed on 50 different patients with 89 dCTA diagnostic examinations performed on 69 different patients. Results: In total, 15.9% of sCTA examinations and 49.4% of dCTA examinations led to the detection of endoleaks. With sCTA, 20.0% of patients were diagnosed with endoleaks, while with dCTA, 37.7% of patients were diagnosed with endoleaks. With sCTA, mainly Type 1 endoleaks were detected, whereas, with dCTA, the types of detected endoleaks were more evenly distributed. In comparison with the literature, the frequencies of endoleak types detected with dCTA better reflect the natural distribution than the frequencies detected with standard CTA. Conclusion: Based on the retrospective comparative evaluation, dCTA could pose a valuable supplementary diagnostic tool resulting in a more accurate and realistic detection and classification of suspected endoleaks.
- 18 May 2022
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 30 (5) , 739-745
Detection of Endoleaks Following Thoracic and Abdominal Aortic Endovascular Aortic Repair—: A Comparison of Standard and Dynamic 4D-Computed Tomography Angiography
Purpose: Endoleaks are a common complication after endovascular aortic repair (EVAR) and thoracic endovascular aortic repair (TEVAR). The detection and correct classification of endoleaks is essential for the further treatment of affected patients. However, standard computed tomography angiography (CTA) provides no hemodynamic information on endoleaks, which can result in misclassification in complex cases. The aim of this study was to compare standard CTA (sCTA) with dynamic, dual-energy CTA (dCTA) for detection and classification of endoleaks following EVAR or TEVAR. Materials and Methods: This retrospective evaluation compared 69 sCTA diagnostic examinations performed on 50 different patients with 89 dCTA diagnostic examinations performed on 69 different patients. Results: In total, 15.9% of sCTA examinations and 49.4% of dCTA examinations led to the detection of endoleaks. With sCTA, 20.0% of patients were diagnosed with endoleaks, while with dCTA, 37.7% of patients were diagnosed with endoleaks. With sCTA, mainly Type 1 endoleaks were detected, whereas, with dCTA, the types of detected endoleaks were more evenly distributed. In comparison with the literature, the frequencies of endoleak types detected with dCTA better reflect the natural distribution than the frequencies detected with standard CTA. Conclusion: Based on the retrospective comparative evaluation, dCTA could pose a valuable supplementary diagnostic tool resulting in a more accurate and realistic detection and classification of suspected endoleaks.
- Open Access
- 4 January 2022
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 98 (5) , 865-872
Radiation exposure during angiographic interventions in interventional radiology – risk and fate of advanced procedures
Advanced angiographic procedures in interventional radiology are becoming more important and are more frequently used, especially in the treatment of several acute life-threatening diseases like st...
- 4 January 2022
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 98 (5) , 865-872
Open AccessRadiation exposure during angiographic interventions in interventional radiology – risk and fate of advanced procedures
Advanced angiographic procedures in interventional radiology are becoming more important and are more frequently used, especially in the treatment of several acute life-threatening diseases like st...
- Open Access
- 2 December 2021
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 98 (5) , 980-985
Impact of medical imaging on the epigenome – low-dose exposure in the course of computed tomography does not induce detectable changes of DNA-methylation profiles in peripheral blood cells
Computed tomography (CT) is a main contributor to artificial low-dose exposure. Understanding the biological effects induced by CT exposure and their dependency on the characteristics of photon spectra is essential for knowledge-driven risk assessment. In a previous gene expression study, we have identified upregulation of AEN, BAX, DDB2, EDA2R and FDXR after ex vivo exposure with single- and dual-energy CT. In this study, we focused on CT-induced changes of DNA methylation. This epigenetic modification of DNA is a central regulator of gene expression and instrumental in preserving genome integrity. Previous studies reported focal hypermethylation and global hypomethylation after exposure with doses above 100 mSv, however, the effect of low dose exposure on DNA methylation is hardly explored. DNA was isolated from peripheral blood of three healthy individuals 6 h after ex vivo exposition to single-energy (80kV and 150kV) and dual-energy CT (80kv/Sn150kV) with a calculated effective dose of 7.0 +/- 0.08 mSv. The experimental setting was identical to the one used in our previous gene expression study enabling a direct comparison of gene expression results with changes of DNA methylation identified in this study. DNA methylation was analyzed by high-throughput sequencing of bisulfite-treated DNA targeted methylation sequencing. Unsupervised hierarchical clustering based on DNA methylation profiles of all samples created three distinct clusters. Formation of these three clusters was solely determined by the origin of samples, indicating the absence of prominent irradiation-associated changes of DNA methylation. In line with this observation, inter-individual comparison of non-irradiated samples revealed 1163, 1224 and 4550 significant differentially methylated regions (DMRs), respectively, whereas the pairwise comparison of irradiated and non-irradiated samples failed to identify irradiation-induced DMRs in any of the three probands. This even applied to the genomic regions harboring AEN, BAX, DDB2, EDA2R and FDXR, the five genes known to be upregulated by CT exposure. CT exposure with various photon spectra did not result in detectable changes of DNA methylation. However, minor effects in a subpopulation of irradiated cells cannot be ruled out. Thus, future studies with extended observation intervals are needed to investigate DNA methylation changes that are induced by indirect effects at later points of time or become detectable by clonal expansion of affected cells. Moreover, our data suggest that the DNA methylation analysis is less sensitive in detecting immediate effects of low-dose irradiation when compared to gene expression analysis.
- 2 December 2021
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 98 (5) , 980-985
Open AccessImpact of medical imaging on the epigenome – low-dose exposure in the course of computed tomography does not induce detectable changes of DNA-methylation profiles in peripheral blood cells
Computed tomography (CT) is a main contributor to artificial low-dose exposure. Understanding the biological effects induced by CT exposure and their dependency on the characteristics of photon spectra is essential for knowledge-driven risk assessment. In a previous gene expression study, we have identified upregulation of AEN, BAX, DDB2, EDA2R and FDXR after ex vivo exposure with single- and dual-energy CT. In this study, we focused on CT-induced changes of DNA methylation. This epigenetic modification of DNA is a central regulator of gene expression and instrumental in preserving genome integrity. Previous studies reported focal hypermethylation and global hypomethylation after exposure with doses above 100 mSv, however, the effect of low dose exposure on DNA methylation is hardly explored. DNA was isolated from peripheral blood of three healthy individuals 6 h after ex vivo exposition to single-energy (80kV and 150kV) and dual-energy CT (80kv/Sn150kV) with a calculated effective dose of 7.0 +/- 0.08 mSv. The experimental setting was identical to the one used in our previous gene expression study enabling a direct comparison of gene expression results with changes of DNA methylation identified in this study. DNA methylation was analyzed by high-throughput sequencing of bisulfite-treated DNA targeted methylation sequencing. Unsupervised hierarchical clustering based on DNA methylation profiles of all samples created three distinct clusters. Formation of these three clusters was solely determined by the origin of samples, indicating the absence of prominent irradiation-associated changes of DNA methylation. In line with this observation, inter-individual comparison of non-irradiated samples revealed 1163, 1224 and 4550 significant differentially methylated regions (DMRs), respectively, whereas the pairwise comparison of irradiated and non-irradiated samples failed to identify irradiation-induced DMRs in any of the three probands. This even applied to the genomic regions harboring AEN, BAX, DDB2, EDA2R and FDXR, the five genes known to be upregulated by CT exposure. CT exposure with various photon spectra did not result in detectable changes of DNA methylation. However, minor effects in a subpopulation of irradiated cells cannot be ruled out. Thus, future studies with extended observation intervals are needed to investigate DNA methylation changes that are induced by indirect effects at later points of time or become detectable by clonal expansion of affected cells. Moreover, our data suggest that the DNA methylation analysis is less sensitive in detecting immediate effects of low-dose irradiation when compared to gene expression analysis.
- Open Access
- 8 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-9
Gene expression changes and DNA damage after ex vivo exposure of peripheral blood cells to various CT photon spectra
Dual-energy CT provides enhanced diagnostic power with similar or even reduced radiation dose as compared to single-energy CT. Its principle is based on the distinct physical properties of low and high energetic photons, which, however, may also affect the biological effectiveness and hence the extent of CT-induced cellular damage. Therefore, a comparative analysis of biological effectiveness of dual- and single-energy CT scans with focus on early gene regulation and frequency of radiation-induced DNA double strand breaks (DSBs) was performed. Blood samples from three healthy individuals were irradiated ex vivo with single-energy (80 kV and 150 kV) and dual-energy tube voltages (80 kV/Sn150kV) employing a modern dual source CT scanner resulting in Volume Computed Tomography Dose Index (CTDIvol) of 15.79–18.26 mGy and dose length product (DLP) of 606.7–613.8 mGy*cm. Non-irradiated samples served as a control. Differential gene expression in peripheral blood mononuclear cells was analyzed 6 h after irradiation using whole transcriptome sequencing. DSB frequency was studied by 53BP1 + γH2AX co-immunostaining and microscopic evaluation of their focal accumulation at DSBs. Neither the analysis of gene expression nor DSB frequency provided any evidence for significantly increased biological effectiveness of dual-energy CT in comparison to samples irradiated with particular single-energy CT spectra. Relative to control, irradiated samples were characterized by a significantly higher rate of DSBs (p < 0.001) and the shared upregulation of five genes, AEN, BAX, DDB2, FDXR and EDA2R, which have already been suggested as radiation-induced biomarkers in previous studies. Despite steadily decreasing doses, CT diagnostics remain a genotoxic stressor with impact on gene regulation and DNA integrity. However, no evidence was found that varying X-ray spectra of CT impact the extent of cellular damage.
- 8 June 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-9
Open AccessGene expression changes and DNA damage after ex vivo exposure of peripheral blood cells to various CT photon spectra
Dual-energy CT provides enhanced diagnostic power with similar or even reduced radiation dose as compared to single-energy CT. Its principle is based on the distinct physical properties of low and high energetic photons, which, however, may also affect the biological effectiveness and hence the extent of CT-induced cellular damage. Therefore, a comparative analysis of biological effectiveness of dual- and single-energy CT scans with focus on early gene regulation and frequency of radiation-induced DNA double strand breaks (DSBs) was performed. Blood samples from three healthy individuals were irradiated ex vivo with single-energy (80 kV and 150 kV) and dual-energy tube voltages (80 kV/Sn150kV) employing a modern dual source CT scanner resulting in Volume Computed Tomography Dose Index (CTDIvol) of 15.79–18.26 mGy and dose length product (DLP) of 606.7–613.8 mGy*cm. Non-irradiated samples served as a control. Differential gene expression in peripheral blood mononuclear cells was analyzed 6 h after irradiation using whole transcriptome sequencing. DSB frequency was studied by 53BP1 + γH2AX co-immunostaining and microscopic evaluation of their focal accumulation at DSBs. Neither the analysis of gene expression nor DSB frequency provided any evidence for significantly increased biological effectiveness of dual-energy CT in comparison to samples irradiated with particular single-energy CT spectra. Relative to control, irradiated samples were characterized by a significantly higher rate of DSBs (p < 0.001) and the shared upregulation of five genes, AEN, BAX, DDB2, FDXR and EDA2R, which have already been suggested as radiation-induced biomarkers in previous studies. Despite steadily decreasing doses, CT diagnostics remain a genotoxic stressor with impact on gene regulation and DNA integrity. However, no evidence was found that varying X-ray spectra of CT impact the extent of cellular damage.
- Open Access
- 24 January 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (3) , 1146
Genomic Adaption and Mutational Patterns in a HaCaT Subline Resistant to Alkylating Agents and Ionizing Radiation
Sulfur mustard (SM) is a chemical warfare agent that can damage DNA via alkylation and oxidative stress. Because of its genotoxicity, SM is cancerogenic and the progenitor of many chemotherapeutics. Previously, we developed an SM-resistant cell line via chronic exposure of the popular keratinocyte cell line HaCaT to increasing doses of SM over a period of 40 months. In this study, we compared the genomic landscape of the SM-resistant cell line HaCaT/SM to its sensitive parental line HaCaT in order to gain insights into genetic changes associated with continuous alkylation and oxidative stress. We established chromosome numbers by cytogenetics, analyzed DNA copy number changes by means of array Comparative Genomic Hybridization (array CGH), employed the genome-wide chromosome conformation capture technique Hi-C to detect chromosomal translocations, and derived mutational signatures by whole-genome sequencing. We observed that chronic SM exposure eliminated the initially prevailing hypotetraploid cell population in favor of a hyperdiploid one, which contrasts with previous observations that link polyploidization to increased tolerance and adaptability toward genotoxic stress. Furthermore, we observed an accumulation of chromosomal translocations, frequently flanked by DNA copy number changes, which indicates a high rate of DNA double-strand breaks and their misrepair. HaCaT/SM-specific single-nucleotide variants showed enrichment of C > A and T > A transversions and a lower rate of deaminated cytosines in the CpG dinucleotide context. Given the frequent use of HaCaT in toxicology, this study provides a valuable data source with respect to the original genotype of HaCaT and the mutational signatures associated with chronic alkylation and oxidative stress.
- 24 January 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (3) , 1146
Open AccessGenomic Adaption and Mutational Patterns in a HaCaT Subline Resistant to Alkylating Agents and Ionizing Radiation
Sulfur mustard (SM) is a chemical warfare agent that can damage DNA via alkylation and oxidative stress. Because of its genotoxicity, SM is cancerogenic and the progenitor of many chemotherapeutics. Previously, we developed an SM-resistant cell line via chronic exposure of the popular keratinocyte cell line HaCaT to increasing doses of SM over a period of 40 months. In this study, we compared the genomic landscape of the SM-resistant cell line HaCaT/SM to its sensitive parental line HaCaT in order to gain insights into genetic changes associated with continuous alkylation and oxidative stress. We established chromosome numbers by cytogenetics, analyzed DNA copy number changes by means of array Comparative Genomic Hybridization (array CGH), employed the genome-wide chromosome conformation capture technique Hi-C to detect chromosomal translocations, and derived mutational signatures by whole-genome sequencing. We observed that chronic SM exposure eliminated the initially prevailing hypotetraploid cell population in favor of a hyperdiploid one, which contrasts with previous observations that link polyploidization to increased tolerance and adaptability toward genotoxic stress. Furthermore, we observed an accumulation of chromosomal translocations, frequently flanked by DNA copy number changes, which indicates a high rate of DNA double-strand breaks and their misrepair. HaCaT/SM-specific single-nucleotide variants showed enrichment of C > A and T > A transversions and a lower rate of deaminated cytosines in the CpG dinucleotide context. Given the frequent use of HaCaT in toxicology, this study provides a valuable data source with respect to the original genotype of HaCaT and the mutational signatures associated with chronic alkylation and oxidative stress.