Multiplexed, rapid point of care platform to quantify allergen-specific IgE
- 1 August 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 478-481
Abstract
Variation of probe immobilization on microarrays hinders the ability to make high quality, assertive and statistically relevant conclusions needed in the healthcare setting. To address this problem, we have developed a calibrated, compact, inexpensive, multiplexed, dual modality point-of-care detection platform that calibrates and correlates surface probe density measured label-free to captured labeled secondary antibody, is independent of chip-to-chip variability, and improves upon existing diagnostic technology. We have identified four major technological advantages of our proposed platform: the capability to perform single spot analysis based on the fluorophore used for detection, a 10-fold gain in fluorescence signal due to optimized substrate, a calibrated, quantitative method that uses the combined fluorescent and label-free modalities to accurately measure the density of probe and bound target for a variety of systems, and a compact measurement platform offering reliable and rapid results at the doctor's office. Already, we have formulated over a 90% linear correlation between the amount of probe bound to surface and the resulting fluorescence of captured target for IgG, β-lactoglobulin, Ara h 1 peanut allergen, and Phl 5a Timothy grass allergen.Keywords
This publication has 20 references indexed in Scilit:
- Silicon biochips for dual label-free and fluorescence detection: Application to protein microarray developmentBiosensors and Bioelectronics, 2011
- Label-free multiplexed virus detection using spectral reflectance imagingBiosensors and Bioelectronics, 2011
- LED-based Interferometric Reflectance Imaging Sensor for quantitative dynamic monitoring of biomolecular interactionsBiosensors and Bioelectronics, 2011
- Label-Free Prehybridization DNA Microarray Imaging Using Photonic Crystals for Quantitative Spot Quality AnalysisAnalytical Chemistry, 2010
- Label-free microarray imaging for direct detection of DNA hybridization and single-nucleotide mismatchesBiosensors and Bioelectronics, 2010
- Spectral Reflectance Imaging for a Multiplexed, High-Throughput, Label-Free, and Dynamic Biosensing PlatformIEEE Journal of Selected Topics in Quantum Electronics, 2010
- High Sensitivity Protein Assays on Microarray Silicon SlidesAnalytical Chemistry, 2009
- Label-free and dynamic detection of biomolecular interactions for high-throughput microarray applicationsProceedings of the National Academy of Sciences, 2008
- Quality Control of Microarray Assays for Toxicogenomic and In Vitro Diagnostic Applications2008
- Spectral self-interference fluorescence microscopyJournal of Applied Physics, 2004