Margo R. Monroe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Margo R. Monroe has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Marcella Chiari
Institute of Chemical and Technological Science “Giulio Natta”, National Research Council of Italy
2 shared publications - Marina Cretich
Istituto di Scienze e Tecnologie Chimiche “Giulio Natta” – National Research Council of Italy (SCITEC-CNR), 20131 Milan, Italy
2 shared publications - Selim Unlu
Department of Electrical and Computer Engineering, Boston University, Boston, USA
2 shared publications Alexander P. Reddington
Department of Electrical and Computer Engineering, Boston University, 8 St. Mary’s Street, Boston, Massachussetts 02215, United States
1 shared publication- Alexander P. Reddington
Department of Electrical and Computer Engineering, Boston University, Boston, MA, USA
1 shared publication Austin D. Collins
Department of Electrical and Computer Engineering, Boston University, 8 St. Mary’s Street, Boston, Massachussetts 02215, United States
1 shared publication
Latest Publications
- 7 November 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (24) , 9485-9491
Multiplexed Method to Calibrate and Quantitate Fluorescence Signal for Allergen-Specific IgE
Using a microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of serum. However, variation of probe immobilization on microarrays hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics. To address this problem, we have developed a calibrated, inexpensive, multiplexed, and rapid protein microarray method that directly correlates surface probe density to captured labeled secondary antibody in clinical samples. We have identified three major technological advantages of our calibrated fluorescence enhancement (CaFE) technique: (i) a significant increase in fluorescence emission over a broad range of fluorophores on a layered substrate optimized specifically for fluorescence; (ii) a method to perform label-free quantification of the probes in each spot while maintaining fluorescence enhancement for a particular fluorophore; and (iii) a calibrated, quantitative technique that combines fluorescence and label-free modalities to accurately measure probe density and bound target for a variety of antibody–antigen pairs. In this paper, we establish the effectiveness of the CaFE method by presenting the strong linear dependence of the amount of bound protein to the resulting fluorescence signal of secondary antibody for IgG, β-lactoglobulin, and allergen-specific IgEs to Ara h 1 (peanut major allergen) and Phl p 1 (timothy grass major allergen) in human serum.
- 7 November 2011
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (24) , 9485-9491
Multiplexed Method to Calibrate and Quantitate Fluorescence Signal for Allergen-Specific IgE
Using a microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of serum. However, variation of probe immobilization on microarrays hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics. To address this problem, we have developed a calibrated, inexpensive, multiplexed, and rapid protein microarray method that directly correlates surface probe density to captured labeled secondary antibody in clinical samples. We have identified three major technological advantages of our calibrated fluorescence enhancement (CaFE) technique: (i) a significant increase in fluorescence emission over a broad range of fluorophores on a layered substrate optimized specifically for fluorescence; (ii) a method to perform label-free quantification of the probes in each spot while maintaining fluorescence enhancement for a particular fluorophore; and (iii) a calibrated, quantitative technique that combines fluorescence and label-free modalities to accurately measure probe density and bound target for a variety of antibody–antigen pairs. In this paper, we establish the effectiveness of the CaFE method by presenting the strong linear dependence of the amount of bound protein to the resulting fluorescence signal of secondary antibody for IgG, β-lactoglobulin, and allergen-specific IgEs to Ara h 1 (peanut major allergen) and Phl p 1 (timothy grass major allergen) in human serum.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 478-481
Multiplexed, rapid point of care platform to quantify allergen-specific IgE
Variation of probe immobilization on microarrays hinders the ability to make high quality, assertive and statistically relevant conclusions needed in the healthcare setting. To address this problem, we have developed a calibrated, compact, inexpensive, multiplexed, dual modality point-of-care detection platform that calibrates and correlates surface probe density measured label-free to captured labeled secondary antibody, is independent of chip-to-chip variability, and improves upon existing diagnostic technology. We have identified four major technological advantages of our proposed platform: the capability to perform single spot analysis based on the fluorophore used for detection, a 10-fold gain in fluorescence signal due to optimized substrate, a calibrated, quantitative method that uses the combined fluorescent and label-free modalities to accurately measure the density of probe and bound target for a variety of systems, and a compact measurement platform offering reliable and rapid results at the doctor's office. Already, we have formulated over a 90% linear correlation between the amount of probe bound to surface and the resulting fluorescence of captured target for IgG, β-lactoglobulin, Ara h 1 peanut allergen, and Phl 5a Timothy grass allergen.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 478-481
Multiplexed, rapid point of care platform to quantify allergen-specific IgE
Variation of probe immobilization on microarrays hinders the ability to make high quality, assertive and statistically relevant conclusions needed in the healthcare setting. To address this problem, we have developed a calibrated, compact, inexpensive, multiplexed, dual modality point-of-care detection platform that calibrates and correlates surface probe density measured label-free to captured labeled secondary antibody, is independent of chip-to-chip variability, and improves upon existing diagnostic technology. We have identified four major technological advantages of our proposed platform: the capability to perform single spot analysis based on the fluorophore used for detection, a 10-fold gain in fluorescence signal due to optimized substrate, a calibrated, quantitative method that uses the combined fluorescent and label-free modalities to accurately measure the density of probe and bound target for a variety of systems, and a compact measurement platform offering reliable and rapid results at the doctor's office. Already, we have formulated over a 90% linear correlation between the amount of probe bound to surface and the resulting fluorescence of captured target for IgG, β-lactoglobulin, Ara h 1 peanut allergen, and Phl 5a Timothy grass allergen.