Abstract
Aims Artificial intelligence has recently been proposed to improve polyp detection. The aim of this study was to evaluate the impact of real-time computer-aided detection (CADe) system on adenoma detection rate (ADR) in routine colonoscopy. Methods This monocenter randomized trial compared standard colonoscopy to CADe-assisted colonoscopy (Genius, Medtronic). According to statistical calculations, twenty endoscopists have to include approximately 2100 patients with a randomization 1:1. Results 2104 patients were included from May 1, 2021 to May 1, 2022. A total of 2015 patients were randomized (1,012 for standard colonoscopy vs. 1,003 for CADe-assisted colonoscopy). ADR and Advanced ADR improved in this study from 33.7% to 37.5% (P=0.051), and from 7.6% to 9.3% (P=0.18) in standard and CADe groups, respectively. Mean number of adenomas per coloscopy (APC) improved from 0.71±1.30 to 0.89±1.49 (P<0.001). The benefit of CADe was not sificantly different regardless of the size of the polyps (P=0.85), and of the endoscopist basal ADR (P=0.60). Conclusions This large prospective randomized study confirms impact of CADe on ADR and APC in routine colonoscopy, even performed in non-academic centers, thus suggesting the systematic use of CADe in routine colonoscopy. ClinicalTrials.gov ID: NCT04440865 Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany