Arnaud Gillet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arnaud Gillet has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
A. Percie Du Sert
Clinique Paris-Bercy, Charenton-le-Pont, France
1 shared publication- Bastien Perrot
INSERM Research Unit UMR 1246 (Methods in Patient‐Centred Outcomes and Health Research, SPHERE) Nantes University, Nantes, France; Tours University Tours France
1 shared publication - David Karsenti
Digestive Endoscopy Unit, Pôle Digestif Paris-Bercy, Clinique Paris-Bercy, Charenton-le-Pont, France
1 shared publication E. Zrihen
Clinique Paris-Bercy, Charenton-le-Pont, France
1 shared publication- Eric Lacoste
Université Bordeaux, Talence, France
1 shared publication F. Venezia
Clinique Paris-Bercy, Charenton-le-Pont, France
1 shared publication
Latest Publications
- 28 September 2023
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 57 (26) , 4169-4181
Influence of the architecture on the strength of a unidirectional composite with recycled discontinuous fibres
Recycled fibre composites are made of discontinuous fibres that are not of the same length. Their mechanical behaviour depends on the load transfer between fibres and in particular on the overlaps between fibres of different lengths. The objective of the study is to show the influence of the architecture on the failure of a discontinuous reinforcement composite. A numerical model was developed to simulate different overlap lengths between fibres. The influence of defects, in this study small overlap length between fibres, and of their distribution in the architecture, was thus highlighted. Experimental tests allowed to validate the model. The model makes it possible to calculate a critical overlap length, length from which the composite strength reaches its maximum. In particular, simulations showed that discontinuous fibre architectures with small overlap lengths at the edge strongly decrease the strength of the composite. On the contrary, defects in the core of the architecture are tolerable. These results open perspectives for the choice of architectures based on recycled fibre in order to optimize the final properties of the composite.
- 28 September 2023
- Published by SAGE Publications in Journal of Composite Materials
- Vol. 57 (26) , 4169-4181
Influence of the architecture on the strength of a unidirectional composite with recycled discontinuous fibres
Recycled fibre composites are made of discontinuous fibres that are not of the same length. Their mechanical behaviour depends on the load transfer between fibres and in particular on the overlaps between fibres of different lengths. The objective of the study is to show the influence of the architecture on the failure of a discontinuous reinforcement composite. A numerical model was developed to simulate different overlap lengths between fibres. The influence of defects, in this study small overlap length between fibres, and of their distribution in the architecture, was thus highlighted. Experimental tests allowed to validate the model. The model makes it possible to calculate a critical overlap length, length from which the composite strength reaches its maximum. In particular, simulations showed that discontinuous fibre architectures with small overlap lengths at the edge strongly decrease the strength of the composite. On the contrary, defects in the core of the architecture are tolerable. These results open perspectives for the choice of architectures based on recycled fibre in order to optimize the final properties of the composite.
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S11-S12
Efficacy of real-time computer-aided detection of colorectal adenoma in a randomized trial in routine
Aims Artificial intelligence has recently been proposed to improve polyp detection. The aim of this study was to evaluate the impact of real-time computer-aided detection (CADe) system on adenoma detection rate (ADR) in routine colonoscopy. Methods This monocenter randomized trial compared standard colonoscopy to CADe-assisted colonoscopy (Genius, Medtronic). According to statistical calculations, twenty endoscopists have to include approximately 2100 patients with a randomization 1:1. Results 2104 patients were included from May 1, 2021 to May 1, 2022. A total of 2015 patients were randomized (1,012 for standard colonoscopy vs. 1,003 for CADe-assisted colonoscopy). ADR and Advanced ADR improved in this study from 33.7% to 37.5% (P=0.051), and from 7.6% to 9.3% (P=0.18) in standard and CADe groups, respectively. Mean number of adenomas per coloscopy (APC) improved from 0.71±1.30 to 0.89±1.49 (P<0.001). The benefit of CADe was not sificantly different regardless of the size of the polyps (P=0.85), and of the endoscopist basal ADR (P=0.60). Conclusions This large prospective randomized study confirms impact of CADe on ADR and APC in routine colonoscopy, even performed in non-academic centers, thus suggesting the systematic use of CADe in routine colonoscopy. ClinicalTrials.gov ID: NCT04440865 Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S11-S12
Efficacy of real-time computer-aided detection of colorectal adenoma in a randomized trial in routine
Aims Artificial intelligence has recently been proposed to improve polyp detection. The aim of this study was to evaluate the impact of real-time computer-aided detection (CADe) system on adenoma detection rate (ADR) in routine colonoscopy. Methods This monocenter randomized trial compared standard colonoscopy to CADe-assisted colonoscopy (Genius, Medtronic). According to statistical calculations, twenty endoscopists have to include approximately 2100 patients with a randomization 1:1. Results 2104 patients were included from May 1, 2021 to May 1, 2022. A total of 2015 patients were randomized (1,012 for standard colonoscopy vs. 1,003 for CADe-assisted colonoscopy). ADR and Advanced ADR improved in this study from 33.7% to 37.5% (P=0.051), and from 7.6% to 9.3% (P=0.18) in standard and CADe groups, respectively. Mean number of adenomas per coloscopy (APC) improved from 0.71±1.30 to 0.89±1.49 (P<0.001). The benefit of CADe was not sificantly different regardless of the size of the polyps (P=0.85), and of the endoscopist basal ADR (P=0.60). Conclusions This large prospective randomized study confirms impact of CADe on ADR and APC in routine colonoscopy, even performed in non-academic centers, thus suggesting the systematic use of CADe in routine colonoscopy. ClinicalTrials.gov ID: NCT04440865 Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany