Three-dimensional finite element analysis of tooth and implant-supported telescopic prosthesis using zirconia, PEKK, and cobalt chromium crowns
Open Access
- 26 January 2026
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Abstract
Objectives: This study aimed to evaluate the biomechanical behavior and stress distribution of tooth–implant-supported telescopic prostheses using different combinations of zirconia, polyetherketoneketone (PEKK), and cobalt–chromium (Co-Cr) materials for primary and secondary crowns by means of three-dimensional finite element analysis (3D FEA). Materials and methods: A three-dimensional finite element model representing a mandibular arch restored with a telescopic overdenture supported by two canines and two implants in the molar region was constructed. Nine prosthetic configurations were analyzed based on different primary and secondary crown material combinations (zirconia, PEKK, and Co-Cr). All materials were assumed to be homogeneous, isotropic, and linearly elastic. Static axial occlusal loads simulating centric occlusion were applied. Von Mises stress distribution was evaluated in prosthetic components, implants, natural teeth, and surrounding bone. Results: Material selection significantly influenced stress distribution within the telescopic system and supporting structures. PEKK used as a secondary crown reduced stress concentrations within the prosthetic crowns but resulted in increased stress transfer to the supporting bone, teeth, and implants compared with zirconia and Co-Cr. When PEKK was used as a primary crown, stress levels within prosthetic components were reduced, while stress transmission to supporting structures was not substantially altered. Zirconia and Co-Cr demonstrated comparable biomechanical behavior across all configurations. In all models, secondary crowns exhibited higher stress values than primary crowns, and implants were subjected to greater loads than natural teeth. Conclusions: Within the limitations of this 3D finite element study, material combinations in tooth–implant-supported telescopic prostheses significantly affect biomechanical stress distribution. PEKK exhibits a material-dependent stress-modulating behavior that should be carefully considered during prosthetic design to balance prosthetic protection and load transfer to supporting structures.Keywords
All Related Versions
Funding Information
- Mansoura University
This publication has 62 references indexed in Scilit:
- The investigation of the stress distribution in abutment teeth for connected crownsJournal of Dental Sciences, 2021
- Retention forces between primary and secondary CAD/CAM manufactured telescopic crowns: an in vitro comparison of common material combinationsClinical Oral Investigations, 2021
- Differences in the biomechanical behaviors of natural teeth and dental implantsDental Materials, 2021
- Polyetherketoneketone (PEKK): An emerging biomaterial for oral implants and dental prosthesesJournal of Advanced Research, 2021
- Experimental Comparison on Dental BioTribological Pairs Zirconia/Zirconia and Zirconia/Natural Tooth by Using a Reciprocating TribometerJournal of Medical Systems, 2019
- Retentive force of PEEK secondary crowns on zirconia primary crowns over timeClinical Oral Investigations, 2018
- Finite element analysis of stress distributions in mono- and bi-cortical dental implantsMaterials Science and Engineering: C, 2015
- Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia—an in vitro studyClinical Oral Investigations, 2013
- Validation of finite element models for strain analysis of implant-supported prostheses using digital image correlationDental Materials, 2013
- A clinical trial of patient satisfaction and prosthodontic needs with ball and bar attachments for implant-retained complete overdentures: Three-year resultsThe Journal of Prosthetic Dentistry, 2005