Aisha Zakaria Hashem Mostafa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aisha Zakaria Hashem Mostafa has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Sameh
Production Engineering and Mechanical Design Department, Faculty of Engineering, Mansoura University, Mansoura, Egypt
2 shared publications - Ahmed Heji Albaqawi
Department of Restorative Dental Science, College of Dentistry, University of Haˈil, Haˈil, Makkah, Kingdom of Saudi Arabia
1 shared publication - Khloud Ezzat Mourad
Department of Removable Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
1 shared publication - Nermeen El Sayed El-Khamisy
Prosthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
1 shared publication Nermeen Elsayed El-Khamisy
Lecturer, Department of removable prosthodontics, Faculty of Dentistry, Mansoura University, Egypt
1 shared publicationSarah Zaman Sahib Awad
Prosthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura City, Egypt
1 shared publication
Latest Publications
- Open Access
- 26 January 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Three-dimensional finite element analysis of tooth and implant-supported telescopic prosthesis using zirconia, PEKK, and cobalt chromium crowns
Objectives: This study aimed to evaluate the biomechanical behavior and stress distribution of tooth–implant-supported telescopic prostheses using different combinations of zirconia, polyetherketoneketone (PEKK), and cobalt–chromium (Co-Cr) materials for primary and secondary crowns by means of three-dimensional finite element analysis (3D FEA). Materials and methods: A three-dimensional finite element model representing a mandibular arch restored with a telescopic overdenture supported by two canines and two implants in the molar region was constructed. Nine prosthetic configurations were analyzed based on different primary and secondary crown material combinations (zirconia, PEKK, and Co-Cr). All materials were assumed to be homogeneous, isotropic, and linearly elastic. Static axial occlusal loads simulating centric occlusion were applied. Von Mises stress distribution was evaluated in prosthetic components, implants, natural teeth, and surrounding bone. Results: Material selection significantly influenced stress distribution within the telescopic system and supporting structures. PEKK used as a secondary crown reduced stress concentrations within the prosthetic crowns but resulted in increased stress transfer to the supporting bone, teeth, and implants compared with zirconia and Co-Cr. When PEKK was used as a primary crown, stress levels within prosthetic components were reduced, while stress transmission to supporting structures was not substantially altered. Zirconia and Co-Cr demonstrated comparable biomechanical behavior across all configurations. In all models, secondary crowns exhibited higher stress values than primary crowns, and implants were subjected to greater loads than natural teeth. Conclusions: Within the limitations of this 3D finite element study, material combinations in tooth–implant-supported telescopic prostheses significantly affect biomechanical stress distribution. PEKK exhibits a material-dependent stress-modulating behavior that should be carefully considered during prosthetic design to balance prosthetic protection and load transfer to supporting structures.
- 26 January 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessThree-dimensional finite element analysis of tooth and implant-supported telescopic prosthesis using zirconia, PEKK, and cobalt chromium crowns
Objectives: This study aimed to evaluate the biomechanical behavior and stress distribution of tooth–implant-supported telescopic prostheses using different combinations of zirconia, polyetherketoneketone (PEKK), and cobalt–chromium (Co-Cr) materials for primary and secondary crowns by means of three-dimensional finite element analysis (3D FEA). Materials and methods: A three-dimensional finite element model representing a mandibular arch restored with a telescopic overdenture supported by two canines and two implants in the molar region was constructed. Nine prosthetic configurations were analyzed based on different primary and secondary crown material combinations (zirconia, PEKK, and Co-Cr). All materials were assumed to be homogeneous, isotropic, and linearly elastic. Static axial occlusal loads simulating centric occlusion were applied. Von Mises stress distribution was evaluated in prosthetic components, implants, natural teeth, and surrounding bone. Results: Material selection significantly influenced stress distribution within the telescopic system and supporting structures. PEKK used as a secondary crown reduced stress concentrations within the prosthetic crowns but resulted in increased stress transfer to the supporting bone, teeth, and implants compared with zirconia and Co-Cr. When PEKK was used as a primary crown, stress levels within prosthetic components were reduced, while stress transmission to supporting structures was not substantially altered. Zirconia and Co-Cr demonstrated comparable biomechanical behavior across all configurations. In all models, secondary crowns exhibited higher stress values than primary crowns, and implants were subjected to greater loads than natural teeth. Conclusions: Within the limitations of this 3D finite element study, material combinations in tooth–implant-supported telescopic prostheses significantly affect biomechanical stress distribution. PEKK exhibits a material-dependent stress-modulating behavior that should be carefully considered during prosthetic design to balance prosthetic protection and load transfer to supporting structures.
- Open Access
- 30 December 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
3D finite element analysis of removable partial denture with lingual bar major connector constructed with cobalt chromium, PEEK, PEKK, and BioHPP
Objective: The current study used finite element analysis (FEA) to investigate the rigidity, through Von-Mises stresses and deformation of cobalt-chromium, Polyetheretherketone (PEEK), Polyetherketoneketone (PEKK), and BioHPP constructed for mandibular class I RPD with lingual bar major connector. Although the general stress–strain relationships followed expected mechanical behavior, this study provides quantitative insight into how different polymeric materials (PEEK, PEKK, BioHPP) compare with conventional cobalt–chromium frameworks under identical loading conditions. Materials and methods: Four virtual models for mandibular Kennedy’s class I situations, with the remaining eight anterior and premolar teeth, were generated that closely resemble the actual cases. Mandibular cobalt-chromium class I RPD with lingual bar major connectors, half pear-shaped, with standard dimensions (50 × 5 × 3 mm), was constructed as a control group. Another 3 models similar to the control group in dimension but with 3 materials, PEEK, PEKK, and Bio HPP, were constructed as study groups. 3D finite element analysis was done, and data were collected and analyzed using bar chart. Results: The PEEK, PEKK, and Bio HPP major connectors showed more deformation (0.1798, 0.17554, 0.17104)mm, indicating weaker rigidity than the cobalt-chromium (0.028999)mm. The maximum von Mises stresses of the cobalt chromium lingual bar were 646.14 MPa, demonstrating stronger rigidity than the PEEK, PEKK, and Bio HPP, which exhibited values of 303.28, 295.29, and 301.23 MPa, respectively. In the case of PEEK and Bio HPP, greater stresses were transmitted to the supporting structures, particularly the mucosa, with maximum von Mises stress values of 3.0319 and 2.3047 MPa. These values were higher than the maximum stress transmitted to the mucosa in cobalt chromium, which was 0.60382 MPa. However, PEKK transmitted lower stresses to the supporting structures, particularly the mucosa, with a maximum von Mises stress value of 0.082096 MPa. Conclusion: Using the same size of PEEK, Bio HPP as the optimal dimensions of the cobalt chromium major connector of the mandibular class I RPD causes increased stress and deflection to the supporting structure, teeth, and soft tissues. This can be assigned to the PEEK’s, Bio HPP, lower stiffness compared to cobalt chromium. On the other hand, PEKK showed decreased stresses and deflection of the supporting structure. When using PEEK and Bio HPP for class I RPD, the mandibular major connector must be larger.
- 30 December 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open Access3D finite element analysis of removable partial denture with lingual bar major connector constructed with cobalt chromium, PEEK, PEKK, and BioHPP
Objective: The current study used finite element analysis (FEA) to investigate the rigidity, through Von-Mises stresses and deformation of cobalt-chromium, Polyetheretherketone (PEEK), Polyetherketoneketone (PEKK), and BioHPP constructed for mandibular class I RPD with lingual bar major connector. Although the general stress–strain relationships followed expected mechanical behavior, this study provides quantitative insight into how different polymeric materials (PEEK, PEKK, BioHPP) compare with conventional cobalt–chromium frameworks under identical loading conditions. Materials and methods: Four virtual models for mandibular Kennedy’s class I situations, with the remaining eight anterior and premolar teeth, were generated that closely resemble the actual cases. Mandibular cobalt-chromium class I RPD with lingual bar major connectors, half pear-shaped, with standard dimensions (50 × 5 × 3 mm), was constructed as a control group. Another 3 models similar to the control group in dimension but with 3 materials, PEEK, PEKK, and Bio HPP, were constructed as study groups. 3D finite element analysis was done, and data were collected and analyzed using bar chart. Results: The PEEK, PEKK, and Bio HPP major connectors showed more deformation (0.1798, 0.17554, 0.17104)mm, indicating weaker rigidity than the cobalt-chromium (0.028999)mm. The maximum von Mises stresses of the cobalt chromium lingual bar were 646.14 MPa, demonstrating stronger rigidity than the PEEK, PEKK, and Bio HPP, which exhibited values of 303.28, 295.29, and 301.23 MPa, respectively. In the case of PEEK and Bio HPP, greater stresses were transmitted to the supporting structures, particularly the mucosa, with maximum von Mises stress values of 3.0319 and 2.3047 MPa. These values were higher than the maximum stress transmitted to the mucosa in cobalt chromium, which was 0.60382 MPa. However, PEKK transmitted lower stresses to the supporting structures, particularly the mucosa, with a maximum von Mises stress value of 0.082096 MPa. Conclusion: Using the same size of PEEK, Bio HPP as the optimal dimensions of the cobalt chromium major connector of the mandibular class I RPD causes increased stress and deflection to the supporting structure, teeth, and soft tissues. This can be assigned to the PEEK’s, Bio HPP, lower stiffness compared to cobalt chromium. On the other hand, PEKK showed decreased stresses and deflection of the supporting structure. When using PEEK and Bio HPP for class I RPD, the mandibular major connector must be larger.
- Open Access
- 1 January 2023
- Published by Mansoura University in Mansoura Journal of Dentistry
- Vol. 10 (4) , 296-306
Two different treatment options for CAD\CAM constructed mandibular class I RPDs. Clinical and radiographic evaluation of abutment teeth tissue health.
Objective: This study was conducted to assess the abutment teeth for digitally constructed clasp-retained and attachment-retained removable partial dentures (RPD) in cases with a class I partially edentulous mandible. Material and methods: In this clinical trial, throughout six years, 10 patients each received two mandibular class I RPDs that were created using computer-aided design and computer-aided manufacturing (CAD-CAM) over six years. The first one was clasp retained RPD (Group1) for 3 years then extra-coronal attachment with cantilever retained RPD for an additional 3 years (Group 2). The abutment's clinical parameters (pocket depth, bleeding index, and plaque index) and alveolar bone level changes were assessed. Result: In Group 1, statistically less bone resorption after 1 year at the mesial side (0.19±0.08), at the distal side (0.61±0.11), compared to Group 2 at mesial (0.26 ±0.07), at distal (0.91 ±0.21) where P value M=0.048, D=0.010. The same result was after 3 years of follow-up P value M=0.008 D=0.004. By the end of each treatment option, there was a statistically significant increase in the abutment alveolar bone resorption, which was accentuated at the distal sides. There were no statistically significant differences between the two treatment options when comparing the clinical parameters of the abutment. By the end of both treatments, the bleeding index, the plaque index, and the probing depth had significantly increased. On the other hand, Group 2 had significantly less abutment mobility compared to Group 1 where P value< 0.001. While the abutment mobility in Group 2 remained the same and significantly increased over time in Group 1. Conclusions: The abutment teeth's alveolar bone is preserved in the clasp retained CAD/CAM constructed RPD while the attachment retained CAD/CAM constructed RPD prevents abutment teeth mobility. Although the clinical parameters tested with the clasp retained RPD better, there was no statistically significant difference when RPD was retained with the attachment. Over time for both treatment groups clinical parameters and bone resorption significantly increased
- 1 January 2023
- Published by Mansoura University in Mansoura Journal of Dentistry
- Vol. 10 (4) , 296-306
Open AccessTwo different treatment options for CAD\CAM constructed mandibular class I RPDs. Clinical and radiographic evaluation of abutment teeth tissue health.
Objective: This study was conducted to assess the abutment teeth for digitally constructed clasp-retained and attachment-retained removable partial dentures (RPD) in cases with a class I partially edentulous mandible. Material and methods: In this clinical trial, throughout six years, 10 patients each received two mandibular class I RPDs that were created using computer-aided design and computer-aided manufacturing (CAD-CAM) over six years. The first one was clasp retained RPD (Group1) for 3 years then extra-coronal attachment with cantilever retained RPD for an additional 3 years (Group 2). The abutment's clinical parameters (pocket depth, bleeding index, and plaque index) and alveolar bone level changes were assessed. Result: In Group 1, statistically less bone resorption after 1 year at the mesial side (0.19±0.08), at the distal side (0.61±0.11), compared to Group 2 at mesial (0.26 ±0.07), at distal (0.91 ±0.21) where P value M=0.048, D=0.010. The same result was after 3 years of follow-up P value M=0.008 D=0.004. By the end of each treatment option, there was a statistically significant increase in the abutment alveolar bone resorption, which was accentuated at the distal sides. There were no statistically significant differences between the two treatment options when comparing the clinical parameters of the abutment. By the end of both treatments, the bleeding index, the plaque index, and the probing depth had significantly increased. On the other hand, Group 2 had significantly less abutment mobility compared to Group 1 where P value< 0.001. While the abutment mobility in Group 2 remained the same and significantly increased over time in Group 1. Conclusions: The abutment teeth's alveolar bone is preserved in the clasp retained CAD/CAM constructed RPD while the attachment retained CAD/CAM constructed RPD prevents abutment teeth mobility. Although the clinical parameters tested with the clasp retained RPD better, there was no statistically significant difference when RPD was retained with the attachment. Over time for both treatment groups clinical parameters and bone resorption significantly increased