Establishment and Application of a Patient-Ventilator Asynchrony Remote Network Platform for ICU Mechanical Ventilation: A Retrospective Study
Open Access
- 16 February 2023
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1570
Abstract
Background: In the process of mechanical ventilation, the problem of patient-ventilator asynchrony (PVA) is faced. This study proposes a self-developed remote mechanical ventilation visualization network system to solve the PVA problem. Method: The algorithm model proposed in this study builds a remote network platform and achieves good results in the identification of ineffective triggering and double triggering abnormalities in mechanical ventilation. Result: The algorithm has a sensitivity recognition rate of 79.89% and a specificity of 94.37%. The sensitivity recognition rate of the trigger anomaly algorithm was as high as 67.17%, and the specificity was 99.92%. Conclusions: The asynchrony index was defined to monitor the patient’s PVA. The system analyzes real-time transmission of respiratory data, identifies double triggering, ineffective triggering, and other anomalies through the constructed algorithm model, and outputs abnormal alarms, data analysis reports, and data visualizations to assist or guide physicians in handling abnormalities, which is expected to improve patients’ breathing conditions and prognosis.Keywords
Funding Information
- National High-level hospital clinical research Funding (2022-PUMCH-B-115, 2022-PUMCH-D-005, 2021-I2M-1-048, 2021-I2M-1-062, Z201100006820126)
- CAMS Innovation Fund for Medical Sciences (2022-PUMCH-B-115, 2022-PUMCH-D-005, 2021-I2M-1-048, 2021-I2M-1-062, Z201100006820126)
- Beijing Nova Program from the Beijing Municipal Science and Technology Commission (2022-PUMCH-B-115, 2022-PUMCH-D-005, 2021-I2M-1-048, 2021-I2M-1-062, Z201100006820126)
- the 5G Network Construction of Remote Intensive care and Application of Critical Infection Standard Diagnosis and Treatment Cloud Platform (2022-PUMCH-B-115, 2022-PUMCH-D-005, 2021-I2M-1-048, 2021-I2M-1-062, Z201100006820126)
This publication has 20 references indexed in Scilit:
- Epidemiological trends in invasive mechanical ventilation in the United States: A population-based studyJournal of Critical Care, 2015
- Parasternal electromyography to determine the relationship between patient-ventilator asynchrony and nocturnal gas exchange during home mechanical ventilation set-upThorax, 2015
- Reverse triggering in a patient with ARDSIntensive Care Medicine, 2015
- Asynchronies during mechanical ventilation are associated with mortalityIntensive Care Medicine, 2015
- Patient–Ventilator Interactions. Implications for Clinical ManagementAmerican Journal of Respiratory and Critical Care Medicine, 2013
- Efficacy of ventilator waveforms observation in detecting patient–ventilator asynchrony*Critical Care Medicine, 2011
- Patient-ventilator asynchrony during assisted mechanical ventilationIntensive Care Medicine, 2006
- Assessment of Physiologic Variables and Subjective Comfort Under Different Levels of Pressure Support VentilationChest, 2004
- Patient–Ventilator InteractionAmerican Journal of Respiratory and Critical Care Medicine, 2001
- Cycling of Inspiratory and Expiratory Muscle Groups with the Ventilator in Airflow LimitationAmerican Journal of Respiratory and Critical Care Medicine, 1998