Yi Chi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Chi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Yun Long
Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, China
4 shared publications - Huaiwu He
Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
3 shared publications - Zhanqi Zhao
School of Biomedical Engineering, Guangzhou Medical University, Guangzhou, China
3 shared publications - Siyi Yuan
State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
2 shared publications - Andy Adler
Carleton University
1 shared publication - Dawei Liu
Department of Critical Care Medicine, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Dongcheng District, Beijing, China
1 shared publication
Latest Publications
- Open Access
- 16 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1570
Establishment and Application of a Patient-Ventilator Asynchrony Remote Network Platform for ICU Mechanical Ventilation: A Retrospective Study
Background: In the process of mechanical ventilation, the problem of patient-ventilator asynchrony (PVA) is faced. This study proposes a self-developed remote mechanical ventilation visualization network system to solve the PVA problem. Method: The algorithm model proposed in this study builds a remote network platform and achieves good results in the identification of ineffective triggering and double triggering abnormalities in mechanical ventilation. Result: The algorithm has a sensitivity recognition rate of 79.89% and a specificity of 94.37%. The sensitivity recognition rate of the trigger anomaly algorithm was as high as 67.17%, and the specificity was 99.92%. Conclusions: The asynchrony index was defined to monitor the patient’s PVA. The system analyzes real-time transmission of respiratory data, identifies double triggering, ineffective triggering, and other anomalies through the constructed algorithm model, and outputs abnormal alarms, data analysis reports, and data visualizations to assist or guide physicians in handling abnormalities, which is expected to improve patients’ breathing conditions and prognosis.
- 16 February 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (4) , 1570
Open AccessEstablishment and Application of a Patient-Ventilator Asynchrony Remote Network Platform for ICU Mechanical Ventilation: A Retrospective Study
Background: In the process of mechanical ventilation, the problem of patient-ventilator asynchrony (PVA) is faced. This study proposes a self-developed remote mechanical ventilation visualization network system to solve the PVA problem. Method: The algorithm model proposed in this study builds a remote network platform and achieves good results in the identification of ineffective triggering and double triggering abnormalities in mechanical ventilation. Result: The algorithm has a sensitivity recognition rate of 79.89% and a specificity of 94.37%. The sensitivity recognition rate of the trigger anomaly algorithm was as high as 67.17%, and the specificity was 99.92%. Conclusions: The asynchrony index was defined to monitor the patient’s PVA. The system analyzes real-time transmission of respiratory data, identifies double triggering, ineffective triggering, and other anomalies through the constructed algorithm model, and outputs abnormal alarms, data analysis reports, and data visualizations to assist or guide physicians in handling abnormalities, which is expected to improve patients’ breathing conditions and prognosis.
- Open Access
- 17 November 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-4
Two regional ventilation–perfusion patterns of lung consolidation assessed by electrical impedance tomography and ultrasound
- 17 November 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-4
Open AccessTwo regional ventilation–perfusion patterns of lung consolidation assessed by electrical impedance tomography and ultrasound
- Open Access
- 5 September 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-4
Saline bolus-based electrical impedance tomography method for rapid bedside assessment of regional lung perfusion during ECMO therapy
- 5 September 2022
- Published by Springer Nature in Critical Care
- Vol. 26 (1) , 1-4
Open AccessSaline bolus-based electrical impedance tomography method for rapid bedside assessment of regional lung perfusion during ECMO therapy
- Open Access
- 25 October 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-9
Twenty-four-hour mechanical power variation rate is associated with mortality among critically ill patients with acute respiratory failure: a retrospective cohort study
Objectives: Defined as the energy applied to the respiratory system by ventilator, mechanical power (MP) of ventilation reflects the risk of ventilation-induced lung injury. This study aims to explore the relationship between dynamic changes in MP and prognosis in critically ill patients. Methods: This was a single-centre retrospective cohort study. Patients receiving mechanical ventilation with acute respiratory failure (ARF) and MP > 10 J/min on admission in the ICU were included. MP (J/min) was calculated as 0.098 × minute ventilation (L/min) × [(peak inspiratory pressure + positive end-expiratory pressure)/2] and the MP variation rate (%) as ([baseline MP − 24-h MP]/baseline MP) × 100. Patients were divided into two groups according to whether MP decreased 24 h after admission (MP-improved group defined as 24-h MP variation rate > 0% vs. MP-worsened group defined as 24-h MP variation rate ≤ 0%). Results: In total, 14,463 patients were screened between January 2015 and June 2020, and finally, a study cohort of 602 patients was obtained. The MP-improved group had a lower ICU mortality rate than the MP-worsened group (24% vs. 36%; p = 0.005). The 24-h MP variation rate was associated with ICU mortality after adjusting for confounders (odds ratio, 0.906 [95% CI 0.833–0.985]; p = 0.021), while baseline MP (p = 0.909) and 24-h MP (p = 0.059) were not. All MP components improved in the MP-improved group, while minute ventilation and positive end-expiratory pressure contributed to the increase in MP in the MP-worsened group. Conclusions: The 24-h MP variation rate was an independent risk factor for ICU mortality among ARF patients with elevated MP. Early decreases in MP may provide prognostic benefits in this population.
- 25 October 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-9
Open AccessTwenty-four-hour mechanical power variation rate is associated with mortality among critically ill patients with acute respiratory failure: a retrospective cohort study
Objectives: Defined as the energy applied to the respiratory system by ventilator, mechanical power (MP) of ventilation reflects the risk of ventilation-induced lung injury. This study aims to explore the relationship between dynamic changes in MP and prognosis in critically ill patients. Methods: This was a single-centre retrospective cohort study. Patients receiving mechanical ventilation with acute respiratory failure (ARF) and MP > 10 J/min on admission in the ICU were included. MP (J/min) was calculated as 0.098 × minute ventilation (L/min) × [(peak inspiratory pressure + positive end-expiratory pressure)/2] and the MP variation rate (%) as ([baseline MP − 24-h MP]/baseline MP) × 100. Patients were divided into two groups according to whether MP decreased 24 h after admission (MP-improved group defined as 24-h MP variation rate > 0% vs. MP-worsened group defined as 24-h MP variation rate ≤ 0%). Results: In total, 14,463 patients were screened between January 2015 and June 2020, and finally, a study cohort of 602 patients was obtained. The MP-improved group had a lower ICU mortality rate than the MP-worsened group (24% vs. 36%; p = 0.005). The 24-h MP variation rate was associated with ICU mortality after adjusting for confounders (odds ratio, 0.906 [95% CI 0.833–0.985]; p = 0.021), while baseline MP (p = 0.909) and 24-h MP (p = 0.059) were not. All MP components improved in the MP-improved group, while minute ventilation and positive end-expiratory pressure contributed to the increase in MP in the MP-worsened group. Conclusions: The 24-h MP variation rate was an independent risk factor for ICU mortality among ARF patients with elevated MP. Early decreases in MP may provide prognostic benefits in this population.