Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures
- 6 November 2010
- journal article
- clinical trial
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (3) , 590-600
Abstract
Purpose Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm2), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of −517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (−435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.Keywords
This publication has 50 references indexed in Scilit:
- Does Sonographic Needle Guidance Affect the Clinical Outcome of Intraarticular Injections?The Journal of Rheumatology, 2009
- Patient safety incidents associated with equipment in critical care: a review of reports to the UK National Patient Safety AgencyAnaesthesia, 2008
- Reciprocating procedure device for thyroid cyst aspiration and ablative sclerotherapyThe Journal of Laryngology & Otology, 2008
- The Patient Safety and Quality Improvement Act of 2005: Provisions and Potential OpportunitiesAmerican Journal of Medical Quality, 2007
- Diagnosis of Hepatocellular CarcinomaJournal of Clinical Gastroenterology, 2002
- Litigation for pneumothorax as a complication of fine-needle aspiration of the breastBritish Journal of Surgery, 2002
- Litigation for pneumothorax as a complication of fine-needle aspiration of the breastBritish Journal of Surgery, 2002
- Percutaneous Adipose Tissue Biopsy by Mini‐Liposuction for Metabolic StudiesJournal of Parenteral and Enteral Nutrition, 1994
- Fine-needle cytology of the breast: A controlled study of aspiration versus nonaspirationDiagnostic Cytopathology, 1991
- Percutaneous lung biopsyAnaesthesia, 1984