Randy R. Sibbitt
Research Subjects
Research Interests
Randy R. Sibbitt has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Arthur D. Bankhurst
University of New Mexico Health Sciences Center
2 shared publications - Wilmer L. Sibbitt
Department of Internal Medicine, University of New Mexico Health Sciences Center, Albuquerque, NM 87131, USA
2 shared publications - Adrian A. Michael
Department of Internal Medicine, Texas Tech University Health Sciences Center, El Paso, USA
1 shared publication - Charles Gasparovic
Department of Neurosciences, University of New Mexico School of Medicine, Albuquerque 87131, USA
1 shared publication - Dennis J. Palmer
Montana Interventional and Diagnostic Radiology, Helena, USA
1 shared publication - Luke J. Haseler
Heart Foundation Research Centre, Griffith Health Institute, Griffith University, Gold Coast, Parklands Drive, Southport, QLD, Australia,
1 shared publication
Latest Publications
- 6 November 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (5) , 1006-1013
Image-Directed Fine-needle Aspiration Biopsy of the Thyroid with Safety-engineered Devices
The purpose of the present study was to integrate safety-engineered devices into outpatient fine-needle aspiration (FNA) biopsy of the thyroid in an interventional radiology practice.
- 6 November 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (5) , 1006-1013
Image-Directed Fine-needle Aspiration Biopsy of the Thyroid with Safety-engineered Devices
The purpose of the present study was to integrate safety-engineered devices into outpatient fine-needle aspiration (FNA) biopsy of the thyroid in an interventional radiology practice.
- 6 November 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (3) , 590-600
Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures
Purpose Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm2), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of −517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (−435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.
- 6 November 2010
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 34 (3) , 590-600
Syringe and Needle Size, Syringe Type, Vacuum Generation, and Needle Control in Aspiration Procedures
Purpose Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm2), (4) operator difficulty during aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of −517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (−435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.