Geosynthetic-encased stone columns (GESCs) are ground improvement elements in which a conventional granular column is wrapped in a high-stiffness geotextile or geogrid sleeve that provides lateral confinement, preventing the radial bulging that limits the load capacity of ordinary stone columns in very soft soils. This research investigated the load-settlement response of GESCs installed beneath a prototype irrigation canal embankment founded on soft organic clay in the lower Mun River floodplain near Nakhon Ratchasima, Thailand. Twelve instrumented stone columns six encased in a woven polypropylene geotextile with an ultimate tensile strength of 200 kN/m and six left unencased as controls were installed by the displacement method to a depth of 8.5 m through organic clay with an undrained shear strength of 8-14 kPa and a natural moisture content of 92-118%. A 3.2 m-high trial embankment was constructed over the treated zone in stages over 16 weeks between March and June 2024, with settlement plates, inclinometers and piezometers monitored continuously until November 2024. At the design embankment pressure of 150 kPa, the median settlement of the encased columns was 23.4 mm compared with 41.7 mm for the ordinary columns and 68.3 mm for the untreated ground reductions of 44% and 66% respectively. The stress concentration ratio for the encased columns reached 4.8, versus 2.9 for the ordinary columns, confirming that the geosynthetic sleeve stiffens the column and attracts a larger share of the applied load. A correlation analysis between column diameter ratio (post-installation diameter divided by design diameter) and settlement showed a Spearman coefficient of -0.74 (p < 0.001) for encased columns, indicating that columns that expanded more during installation settled less. Three tables and two figures a box plot of settlement distributions and a cycle diagram of the load transfer mechanism present the key outcomes. The encased columns also showed 63% less lateral displacement at the column mid-depth than the ordinary columns, confirming the confinement function of the geosynthetic. Cost analysis showed a 24% premium for encasement over ordinary stone columns, offset by a 31% reduction in required column length due to the higher load capacity per unit length. These results support the use of GESCs as a cost-effective ground improvement solution for irrigation canal embankments on soft organic deposits where ordinary stone columns would undergo excessive bulging.