Acoustic Sensing as a Novel Wearable Approach for Heart Rate Variability Monitoring at the Wrist
- 11 June 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Abstract
Heart rate variability (HRV) is an important physiological parameter to assess the status of the autonomic nervous system (ANS) and diagnose cardiovascular diseases (CVDs). HRV is generally extracted from the cardiac activity monitored at the chest using electrocardiography (ECG). This article presents a novel algorithm to accurately extract HRV, from signals obtained using an innovative wearable approach based on acoustic sensing of cardiac activity at the wrist. The proposed methodology is based on the relative energy method, which utilizes the relative information between short and long-term energies of the acoustic signal to enhance the S1’s characteristics in comparison to other signal transitions. The algorithm was tested on a dataset consisting of acoustic recordings of 5-min duration obtained from 12 subjects. For the instantaneous heart rate (IHR) determination, 98.50% and 98.96% of the total samples achieved a relative error of less than ±5% when compared to ECG and photoplethysmography (PPG) signals, respectively. The comparison of the HRV parameters in the time-domain and the frequency-domain, with the reference signals, also demonstrated a strong statistical agreement and correlation of close to one, hence proving the feasibility of extracting the HRV from acoustic signals recorded at the wrist.Keywords
Funding Information
- European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation program (724 334)
This publication has 22 references indexed in Scilit:
- Nonparametric Statistical Inference2011
- The relationship between heart rate variability and inflammatory markers in cardiovascular diseasesPsychoneuroendocrinology, 2008
- Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiographyJournal of Medical Engineering & Technology, 2008
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Heart rate variability: a reviewMedical & Biological Engineering & Computing, 2006
- Spectral analysis of heart rate variability: interchangeability between autoregressive analysis and fast Fourier transformJournal of Electrocardiology, 2006
- Baroreflex sensitivity and heart-rate variability in prediction of total cardiac mortality after myocardial infarctionThe Lancet, 1998
- Heart Rate VariabilityAnnals of Noninvasive Electrocardiology, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Least-squares frequency analysis of unequally spaced dataAstrophysics and Space Science, 1976