Piyush Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Piyush Sharma has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Esther Rodriguez-Villegas
Department of Electrical and Electronic Engineering, Wearable Technologies Laboratory, Imperial College London, London, U.K.
2 shared publications Esther Rodriguez-Villegas
Department of Electrical and Electronic Engineering, Imperial College London, London, UK
1 shared publicationGary Holness
1 shared publicationKailash Chandra Ray
Department of Electrical Engineering Indian Institute of Technology Patna Bihar 801103 India
1 shared publication- Noureddine Melikechi
Kennedy College of Sciences, University of Massachusetts Lowell, Lowell, MA 01854, USA
1 shared publication - Poopalasingam Sivakumar
Department of Physics, Southern Illinois University Carbondale, 1245 Lincoln Dr. Neckers 483-A, Carbondale, IL 62901, USA
1 shared publication
Latest Publications
- 11 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Acoustic Sensing as a Novel Wearable Approach for Heart Rate Variability Monitoring at the Wrist
Heart rate variability (HRV) is an important physiological parameter to assess the status of the autonomic nervous system (ANS) and diagnose cardiovascular diseases (CVDs). HRV is generally extracted from the cardiac activity monitored at the chest using electrocardiography (ECG). This article presents a novel algorithm to accurately extract HRV, from signals obtained using an innovative wearable approach based on acoustic sensing of cardiac activity at the wrist. The proposed methodology is based on the relative energy method, which utilizes the relative information between short and long-term energies of the acoustic signal to enhance the S1’s characteristics in comparison to other signal transitions. The algorithm was tested on a dataset consisting of acoustic recordings of 5-min duration obtained from 12 subjects. For the instantaneous heart rate (IHR) determination, 98.50% and 98.96% of the total samples achieved a relative error of less than ±5% when compared to ECG and photoplethysmography (PPG) signals, respectively. The comparison of the HRV parameters in the time-domain and the frequency-domain, with the reference signals, also demonstrated a strong statistical agreement and correlation of close to one, hence proving the feasibility of extracting the HRV from acoustic signals recorded at the wrist.
- 11 June 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Acoustic Sensing as a Novel Wearable Approach for Heart Rate Variability Monitoring at the Wrist
Heart rate variability (HRV) is an important physiological parameter to assess the status of the autonomic nervous system (ANS) and diagnose cardiovascular diseases (CVDs). HRV is generally extracted from the cardiac activity monitored at the chest using electrocardiography (ECG). This article presents a novel algorithm to accurately extract HRV, from signals obtained using an innovative wearable approach based on acoustic sensing of cardiac activity at the wrist. The proposed methodology is based on the relative energy method, which utilizes the relative information between short and long-term energies of the acoustic signal to enhance the S1’s characteristics in comparison to other signal transitions. The algorithm was tested on a dataset consisting of acoustic recordings of 5-min duration obtained from 12 subjects. For the instantaneous heart rate (IHR) determination, 98.50% and 98.96% of the total samples achieved a relative error of less than ±5% when compared to ECG and photoplethysmography (PPG) signals, respectively. The comparison of the HRV parameters in the time-domain and the frequency-domain, with the reference signals, also demonstrated a strong statistical agreement and correlation of close to one, hence proving the feasibility of extracting the HRV from acoustic signals recorded at the wrist.
- Open Access
Investigating Manifold Neighborhood size for Nonlinear Analysis of LIBS Amino Acid Spectra
Classification and identification of amino acids in aqueous solutions is important in the study of biomacromolecules. Laser Induced Breakdown Spectroscopy (LIBS) uses high energy laser-pulses for ablation of chemical compounds whose radiated spectra are captured and recorded to reveal molecular structure. Spectral peaks and noise from LIBS are impacted by experimental protocols. Current methods for LIBS spectral analysis achieves promising results using PCA, a linear method. It is well-known that the underlying physical processes behind LIBS are highly nonlinear. Our work set out to understand the impact of LIBS spectra on suitable neighborhood size over which to consider pattern phenomena, if nonlinear methods capture pattern phenomena with increased efficacy, and how they improve classification and identification of compounds. We analyzed four amino acids, polysaccharide, and a control group, water. We developed an information theoretic method for measurement of LIBS energy spectra, implemented manifold methods for nonlinear dimensionality reduction, and found while clustering results were not statistically significantly different, nonlinear methods lead to increased classification accuracy. Moreover, our approach uncovered the contribution of micro-wells (experimental protocol) in LIBS spectra. To the best of our knowledge, ours is the first application of Manifold methods to LIBS amino-acid analysis in the research literature.
Open AccessInvestigating Manifold Neighborhood size for Nonlinear Analysis of LIBS Amino Acid Spectra
Classification and identification of amino acids in aqueous solutions is important in the study of biomacromolecules. Laser Induced Breakdown Spectroscopy (LIBS) uses high energy laser-pulses for ablation of chemical compounds whose radiated spectra are captured and recorded to reveal molecular structure. Spectral peaks and noise from LIBS are impacted by experimental protocols. Current methods for LIBS spectral analysis achieves promising results using PCA, a linear method. It is well-known that the underlying physical processes behind LIBS are highly nonlinear. Our work set out to understand the impact of LIBS spectra on suitable neighborhood size over which to consider pattern phenomena, if nonlinear methods capture pattern phenomena with increased efficacy, and how they improve classification and identification of compounds. We analyzed four amino acids, polysaccharide, and a control group, water. We developed an information theoretic method for measurement of LIBS energy spectra, implemented manifold methods for nonlinear dimensionality reduction, and found while clustering results were not statistically significantly different, nonlinear methods lead to increased classification accuracy. Moreover, our approach uncovered the contribution of micro-wells (experimental protocol) in LIBS spectra. To the best of our knowledge, ours is the first application of Manifold methods to LIBS amino-acid analysis in the research literature.
- Open Access
- 27 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-13
Acoustic Sensing as a Novel Wearable Approach for Cardiac Monitoring at the Wrist
This paper introduces the concept of using acoustic sensing over the radial artery to extract cardiac parameters for continuous vital sign monitoring. It proposes a novel measurement principle that allows detection of the heart sounds together with the pulse wave, an attribute not possible with existing photoplethysmography (PPG)-based methods for monitoring at the wrist. The validity of the proposed principle is demonstrated using a new miniature, battery-operated wearable device to sense the acoustic signals and a novel algorithm to extract the heart rate from these signals. The algorithm utilizes the power spectral analysis of the acoustic pulse signal to detect the S1 sounds and additionally, the K-means method to remove motion artifacts for an accurate heartbeat detection. It has been validated on a dataset consisting of 12 subjects with a data length of 6 hours. The results demonstrate an accuracy of 98.78%, mean absolute error of 0.28 bpm, limits of agreement between −1.68 and 1.69 bpm, and a correlation coefficient of 0.998 with reference to a state-of-the-art PPG-based commercial device. The results in this proof of concept study demonstrate the potential of this new sensing modality to be used as an alternative, or to complement existing methods, for continuous monitoring of heart rate at the wrist.
- 27 December 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-13
Open AccessAcoustic Sensing as a Novel Wearable Approach for Cardiac Monitoring at the Wrist
This paper introduces the concept of using acoustic sensing over the radial artery to extract cardiac parameters for continuous vital sign monitoring. It proposes a novel measurement principle that allows detection of the heart sounds together with the pulse wave, an attribute not possible with existing photoplethysmography (PPG)-based methods for monitoring at the wrist. The validity of the proposed principle is demonstrated using a new miniature, battery-operated wearable device to sense the acoustic signals and a novel algorithm to extract the heart rate from these signals. The algorithm utilizes the power spectral analysis of the acoustic pulse signal to detect the S1 sounds and additionally, the K-means method to remove motion artifacts for an accurate heartbeat detection. It has been validated on a dataset consisting of 12 subjects with a data length of 6 hours. The results demonstrate an accuracy of 98.78%, mean absolute error of 0.28 bpm, limits of agreement between −1.68 and 1.69 bpm, and a correlation coefficient of 0.998 with reference to a state-of-the-art PPG-based commercial device. The results in this proof of concept study demonstrate the potential of this new sensing modality to be used as an alternative, or to complement existing methods, for continuous monitoring of heart rate at the wrist.
- Open Access
- 18 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (1) , 246-256
An Algorithm for Heart Rate Extraction From Acoustic Recordings at the Neck
Heart rate is an important physiological parameter to assess the cardiac condition of an individual and is traditionally determined by attaching multiple electrodes on the chest of a subject to record the electrical activity of the heart. The installation and handling complexities of such systems does not prove feasible for a user to undergo a long-term monitoring in the home settings. A small-sized, battery-operated wearable monitoring device is placed on the suprasternal notch at neck to record acoustic signals containing information about breathing and cardiac sounds. The heart sounds obtained are heavily corrupted by the respiratory cycles and other external artifacts. This paper presents a novel algorithm for reliably extracting the heart rate from such acoustic recordings, keeping in mind the constraints posed by the wearable technology. The methodology constructs the Hilbert energy envelope of the signal by calculating its instantaneous characteristics to segment and classify a cardiac cycle into S1 and S2 sounds using their timing characteristics. The algorithm is tested on a dataset consisting of 13 subjects with an approximate data length of 75 hours and achieves an accuracy of 94.34%, an RMS error of 3.96 bpm and a correlation coefficient of 0.93 with reference to a commercial device in use.
- 18 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (1) , 246-256
Open AccessAn Algorithm for Heart Rate Extraction From Acoustic Recordings at the Neck
Heart rate is an important physiological parameter to assess the cardiac condition of an individual and is traditionally determined by attaching multiple electrodes on the chest of a subject to record the electrical activity of the heart. The installation and handling complexities of such systems does not prove feasible for a user to undergo a long-term monitoring in the home settings. A small-sized, battery-operated wearable monitoring device is placed on the suprasternal notch at neck to record acoustic signals containing information about breathing and cardiac sounds. The heart sounds obtained are heavily corrupted by the respiratory cycles and other external artifacts. This paper presents a novel algorithm for reliably extracting the heart rate from such acoustic recordings, keeping in mind the constraints posed by the wearable technology. The methodology constructs the Hilbert energy envelope of the signal by calculating its instantaneous characteristics to segment and classify a cardiac cycle into S1 and S2 sounds using their timing characteristics. The algorithm is tested on a dataset consisting of 13 subjects with an approximate data length of 75 hours and achieves an accuracy of 94.34%, an RMS error of 3.96 bpm and a correlation coefficient of 0.93 with reference to a commercial device in use.
- Open Access
- 1 September 2016
- Published by Institution of Engineering and Technology (IET) in IET Signal Processing
- Vol. 10 (7) , 825-832
Efficient methodology for electrocardiogram beat classification
Electrocardiogram (ECG) beat behaves as a non‐linear and non‐stationary signal. Since most of the existing data processing tools are poor alternatives for processing such signals, Hilbert–Huang transform (HHT) proves to be an efficient method as it deals with a time‐varying frequency spectrum. In this study, a new and efficient methodology is proposed using HHT for feature selection which includes a set of essential features such as weighted mean frequency, Kolmogorov complexity and other statistical features (median, standard deviation, kurtosis, skewness and central moment) computed from the intrinsic mode functions extracted using the empirical mode decomposition (EMD) algorithm. Further, one‐against‐one multi‐class support vector machine is employed for the classification of six generic ECG beats, namely: normal, left bundle branch block, right bundle branch block, premature ventricular contraction, paced beat and atrial premature beat. The classification process in this study yields better results than existing methodologies in terms of classification accuracy equal to 99.51% along with sensitivity, specificity and positive predictivity of 98.64, 99.77 and 98.17%, respectively.
- 1 September 2016
- Published by Institution of Engineering and Technology (IET) in IET Signal Processing
- Vol. 10 (7) , 825-832
Open AccessEfficient methodology for electrocardiogram beat classification
Electrocardiogram (ECG) beat behaves as a non‐linear and non‐stationary signal. Since most of the existing data processing tools are poor alternatives for processing such signals, Hilbert–Huang transform (HHT) proves to be an efficient method as it deals with a time‐varying frequency spectrum. In this study, a new and efficient methodology is proposed using HHT for feature selection which includes a set of essential features such as weighted mean frequency, Kolmogorov complexity and other statistical features (median, standard deviation, kurtosis, skewness and central moment) computed from the intrinsic mode functions extracted using the empirical mode decomposition (EMD) algorithm. Further, one‐against‐one multi‐class support vector machine is employed for the classification of six generic ECG beats, namely: normal, left bundle branch block, right bundle branch block, premature ventricular contraction, paced beat and atrial premature beat. The classification process in this study yields better results than existing methodologies in terms of classification accuracy equal to 99.51% along with sensitivity, specificity and positive predictivity of 98.64, 99.77 and 98.17%, respectively.