Quantification of trace fenuron in waste water samples by matrix matching calibration strategy and gas chromatography–mass spectrometry after simultaneous derivatization and preconcentration
- 18 August 2023
- journal article
- research article
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 195 (9) , 1-12
Abstract
This study presents a highly sensitive and accurate analytical strategy for the determination of fenuron in wastewater samples using gas chromatography–mass spectrometry (GC-MS). Simultaneous derivatization and spray-based fine droplet formation–liquid phase microextraction (SFDF-LPME) method was developed and performed to achieve low detection limits. The parameters of the derivatization and SFDF-LPME method were optimized by univariate approach to improve sensitivity and selectivity. Under the optimum SFDF-LPME-GC-MS conditions, the limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.15 and 0.49 mg/kg, respectively. In addition, the linear range was calculated as 0.51–24.50 mg/kg. Recovery studies were carried out on wastewater samples to determine the accuracy of the developed method and its applicability to real sample matrix. Matrix matching calibration strategy was applied to eliminate/reduce any possible interference effects caused by the complexity of the wastewater matrix and to increase the accuracy of the analytical results. Percent recovery results varied between 85.9 and 120.9% with small percent relative standard deviation values. These results were satisfactory in terms of the accuracy and applicability of the proposed method for wastewater samples.Keywords
This publication has 37 references indexed in Scilit:
- Dispersive liquid-liquid microextractionTrAC Trends in Analytical Chemistry, 2011
- Optimization of the liquid–liquid extraction method and low temperature purification (LLE–LTP) for pesticide residue analysis in honey samples by gas chromatographyFood Control, 2010
- A simple and rapid new dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with inductively coupled plasma-optical emission spectrometry for preconcentration and determination of aluminium in water samplesJournal of Hazardous Materials, 2010
- Kinetics of oxidative degradation/mineralization pathways of the phenylurea herbicides diuron, monuron and fenuron in water during application of the electro-Fenton processApplied Catalysis B: Environment and Energy, 2010
- Dispersive solid-phase extraction followed by dispersive liquid–liquid microextraction for the determination of some sulfonylurea herbicides in soil by high-performance liquid chromatographyJournal of Chromatography A, 2009
- Simultaneous determination of 15 phenylurea herbicides in rice and corn using HPLC with fluorescence detection combined with UV decomposition and post-column derivatizationJournal of Chromatography B, 2008
- Dispersive liquid phase microextraction (DLPME) combined with graphite furnace atomic absorption spectrometry (GFAAS) for determination of trace Co and Ni in environmental water and rice samplesTalanta, 2008
- Simultaneous determination of phenyl- and sulfonylurea herbicides in water by solid-phase extraction and liquid chromatography with UV diode array or mass spectrometric detectionAnalytica Chimica Acta, 2004
- Analysis of phenylurea herbicides from plants by GC/MSTalanta, 2002
- Determination of herbicides in surface water by means of a supported liquid membrane technique and high-performance liquid chromatographyJournal of Chromatography A, 1996