Fatma Turak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fatma Turak has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Sezgin Bakırdere
Faculty of Art and Science, Department of Chemistry, Yıldız Technical University, İstanbul, Türkiye
10 shared publications - Buse Tuğba Zaman
Department of Chemistry, Faculty of Arts and Science, Yıldız Technical University, İstanbul, Turkiye
3 shared publications Buse Tuğba Zaman
Yıldız Technical University, Faculty of Art and Science, Department of Chemistry, İstanbul, Turkey
2 shared publications- Dotse Selali Chormey
Chemistry Department, Yıldız Technical University, Istanbul, Turkey
2 shared publications - Elif Öztürk Er
Department of Chemical Engineering, Istanbul Technical University, Istanbul, Turkey
2 shared publications - Hakan Serbest
Department of Conservation and Restoration of Cultural Property, School of Conservation and Restoration of Cultural Property, Mimar Sinan Fine Arts University, İstanbul, Türkiye
2 shared publications
Latest Publications
- 25 March 2026
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 198 (4) , 349
Development of a dispersive solid phase extraction method based on copper-metal organic framework nanoparticles for the determination of lead at trace levels in stream samples
In this study, a facile, rapid, and cost-effective method was developed for the determination of lead ions using copper-metal organic framework (Cu-MOF) nanoparticles based dispersive solid phase extraction (DSPE) in slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS) system. Cu-MOF nanoparticles were used as sorbents, and SQT was used to increase the residence time of lead atoms in the light path. The limit of detection (LOD) and limit of quantification (LOQ) of the Cu-MOF-DSPE-SQT-FAAS system were calculated as 7.1 µg L−1 and 23.5 µg L−1 under optimum experimental conditions, respectively. The regression coefficient (R2) was found to be 0.9967, and the linear operating range was determined between 15 and 300 µg L−1. Thanks to the developed method, a 103.7-fold improvement was achieved for the sensitivity of the traditional FAAS system by comparing the slopes of the linear calibration plot equations. The feasibility of the proposed method was investigated by spiking experiments with utilizing the stream water samples. The good recovery results obtained in the range of 90.8% to 127.1% demonstrated the applicability of the developed method to river water samples with high accuracy and precision. Cu-MOF structures have been employed for the first time for the preconcentration of Pb ions, and their prominent surface properties suggest that they may also be applicable for other analytical processes for different analytes.
- 25 March 2026
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 198 (4) , 349
Development of a dispersive solid phase extraction method based on copper-metal organic framework nanoparticles for the determination of lead at trace levels in stream samples
In this study, a facile, rapid, and cost-effective method was developed for the determination of lead ions using copper-metal organic framework (Cu-MOF) nanoparticles based dispersive solid phase extraction (DSPE) in slotted quartz tube-flame atomic absorption spectrometry (SQT-FAAS) system. Cu-MOF nanoparticles were used as sorbents, and SQT was used to increase the residence time of lead atoms in the light path. The limit of detection (LOD) and limit of quantification (LOQ) of the Cu-MOF-DSPE-SQT-FAAS system were calculated as 7.1 µg L−1 and 23.5 µg L−1 under optimum experimental conditions, respectively. The regression coefficient (R2) was found to be 0.9967, and the linear operating range was determined between 15 and 300 µg L−1. Thanks to the developed method, a 103.7-fold improvement was achieved for the sensitivity of the traditional FAAS system by comparing the slopes of the linear calibration plot equations. The feasibility of the proposed method was investigated by spiking experiments with utilizing the stream water samples. The good recovery results obtained in the range of 90.8% to 127.1% demonstrated the applicability of the developed method to river water samples with high accuracy and precision. Cu-MOF structures have been employed for the first time for the preconcentration of Pb ions, and their prominent surface properties suggest that they may also be applicable for other analytical processes for different analytes.
- Open Access
- 26 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Investigation of cadmium removal using tin oxide nanoflowers through process optimization, isotherms and kinetics
The present study demonstrates a treatment approach that utilizes flower-shaped tin oxide nanoparticles for the removal of cadmium from synthetic wastewater by adsorption. Tin oxide nanoparticles were synthesized using a simple and eco-friendly method and employed for the removal of cadmium ions from wastewater. The nanoflowers were successfully characterized using Fourier Transform Infrared Spectroscopy, X-Ray Diffraction Analysis, Scanning Electron Microscope and Brunauer-Emmett-Teller (BET) surface area analysis. The batch adsorption process was optimized by response surface methods to investigate the influential parameters of the adsorption process. Optimal removal efficacy was achieved at a pH value of 9.0, a mixing time of 20 min, and an adsorbent amount of 15 mg. The results indicated that the adsorbent achieved a maximum removal efficiency of 99.14 ± 0.10% for Cd(II)ions in domestic wastewater. The adsorption equilibrium process was elucidated by Langmuir, Freundlich, Sips and Toth isotherm models using nonlinear regression. In addition, error functions such as Chi-square (X2, Average Relative Error (ARE), Root Mean Squared Error (RMSE) and HYBRID were used to test the validity of the nonlinear models. The results indicated that the Sips model, with an R2 value of 0.9894, accurately matched the experimental data and adsorption capacity of 57.12 mg g− 1 for Cd(II) was calculated respectively. The sorption kinetics were well characterized by a pseudo-second-order kinetic model. The results demonstrated that adsorption of cadmium onto the surface of SnO2 nanoparticles is influenced by both monolayer adsorption and multi-site interactions. These findings indicate that SnO2 nanoparticles are suitable for removing cadmium from aqueous solutions in batch processes.
- 26 April 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-15
Open AccessInvestigation of cadmium removal using tin oxide nanoflowers through process optimization, isotherms and kinetics
The present study demonstrates a treatment approach that utilizes flower-shaped tin oxide nanoparticles for the removal of cadmium from synthetic wastewater by adsorption. Tin oxide nanoparticles were synthesized using a simple and eco-friendly method and employed for the removal of cadmium ions from wastewater. The nanoflowers were successfully characterized using Fourier Transform Infrared Spectroscopy, X-Ray Diffraction Analysis, Scanning Electron Microscope and Brunauer-Emmett-Teller (BET) surface area analysis. The batch adsorption process was optimized by response surface methods to investigate the influential parameters of the adsorption process. Optimal removal efficacy was achieved at a pH value of 9.0, a mixing time of 20 min, and an adsorbent amount of 15 mg. The results indicated that the adsorbent achieved a maximum removal efficiency of 99.14 ± 0.10% for Cd(II)ions in domestic wastewater. The adsorption equilibrium process was elucidated by Langmuir, Freundlich, Sips and Toth isotherm models using nonlinear regression. In addition, error functions such as Chi-square (X2, Average Relative Error (ARE), Root Mean Squared Error (RMSE) and HYBRID were used to test the validity of the nonlinear models. The results indicated that the Sips model, with an R2 value of 0.9894, accurately matched the experimental data and adsorption capacity of 57.12 mg g− 1 for Cd(II) was calculated respectively. The sorption kinetics were well characterized by a pseudo-second-order kinetic model. The results demonstrated that adsorption of cadmium onto the surface of SnO2 nanoparticles is influenced by both monolayer adsorption and multi-site interactions. These findings indicate that SnO2 nanoparticles are suitable for removing cadmium from aqueous solutions in batch processes.
- 1 October 2024
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 196 (10) , 1-14
Microwave-assisted synthesis of γ-alooh nanoflowers as an adsorbent for cadmium removal from domestic wastewater
In this study, cadmium ions were effectively removed from domestic wastewaters using an adsorptive treatment strategy based on γ-AlOOH nanoflowers. A novel, rapid, and simple procedure was developed for the synthesis of the nanoflowers. Characterization studies were performed using X-ray powder diffraction patterns and scanning electron microscope images. The synthesized nanoflowers were utilized as adsorbent in the batch adsorption experiments. The influential parameters of the adsorption process were optimized, and a flame atomic absorption spectrophotometry (FAAS) system was used to determine maximum percent removal of cadmium ions. Matrix-matched calibration strategy, in which the calibration plot was developed in wastewater medium, was utilized for the accurate and precise quantification of cadmium in the effluent samples. The percentage removal efficiency values were calculated between 84 and 98% for different concentrations of cadmium ions in the wastewater samples. Equilibrium data was fitted to the four different linearization methods of the Langmuir isotherm model, as well as the Freundlich isotherm model and Elovich isotherm model. The best fitting was achieved for the Langmuir model with a high R2 value of 0.9956 and maximum adsorption capacity was calculated as 6.23 mg/g.
- 1 October 2024
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 196 (10) , 1-14
Microwave-assisted synthesis of γ-alooh nanoflowers as an adsorbent for cadmium removal from domestic wastewater
In this study, cadmium ions were effectively removed from domestic wastewaters using an adsorptive treatment strategy based on γ-AlOOH nanoflowers. A novel, rapid, and simple procedure was developed for the synthesis of the nanoflowers. Characterization studies were performed using X-ray powder diffraction patterns and scanning electron microscope images. The synthesized nanoflowers were utilized as adsorbent in the batch adsorption experiments. The influential parameters of the adsorption process were optimized, and a flame atomic absorption spectrophotometry (FAAS) system was used to determine maximum percent removal of cadmium ions. Matrix-matched calibration strategy, in which the calibration plot was developed in wastewater medium, was utilized for the accurate and precise quantification of cadmium in the effluent samples. The percentage removal efficiency values were calculated between 84 and 98% for different concentrations of cadmium ions in the wastewater samples. Equilibrium data was fitted to the four different linearization methods of the Langmuir isotherm model, as well as the Freundlich isotherm model and Elovich isotherm model. The best fitting was achieved for the Langmuir model with a high R2 value of 0.9956 and maximum adsorption capacity was calculated as 6.23 mg/g.
- Open Access
- 31 October 2023
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 47 (5) , 1075-1084
Combination of smartphone digital image colorimetry and UV-Vis spectrophotometry as detection systems with solidified floating organic drop microextraction as preconcentration method for the quantification of methyl red in wastewater samples
In this study, a portable smartphone-based digital image colorimetric system (SDIC) was designed and integrated with a solidified floating organic drop microextraction method (SFODME) for the quantification of methyl red in textile wastewater samples. The RGB (red, green, and blue) data were evaluated for each captured image, and the green channel was selected for quantification due to its linear response for the analyte. Under optimal conditions, an acceptable linear range was recorded for the analyte. The proposed method recorded a limit of detection (LOD) value of 0.046 mg/L. The developed microextraction method was also combined with UVVis spectrophotometry, which recorded an LOD value of 0.012 mg/L. Real sample analysis was carried out with textile wastewater samples to check the applicability/accuracy of the developed method, using a matrix matching calibration strategy to enhance quantification accuracy. Satisfactory percent recoveries in the range of 93.3%-114.3% and 92%-92.7% were recorded for the SFODME-SDIC and SFODME-UV methods, respectively.
- 31 October 2023
- Published by The Scientific and Technological Research Council of Turkey (TUBITAK-ULAKBIM) - DIGITAL COMMONS JOURNALS in TURKISH JOURNAL OF CHEMISTRY
- Vol. 47 (5) , 1075-1084
Open AccessCombination of smartphone digital image colorimetry and UV-Vis spectrophotometry as detection systems with solidified floating organic drop microextraction as preconcentration method for the quantification of methyl red in wastewater samples
In this study, a portable smartphone-based digital image colorimetric system (SDIC) was designed and integrated with a solidified floating organic drop microextraction method (SFODME) for the quantification of methyl red in textile wastewater samples. The RGB (red, green, and blue) data were evaluated for each captured image, and the green channel was selected for quantification due to its linear response for the analyte. Under optimal conditions, an acceptable linear range was recorded for the analyte. The proposed method recorded a limit of detection (LOD) value of 0.046 mg/L. The developed microextraction method was also combined with UVVis spectrophotometry, which recorded an LOD value of 0.012 mg/L. Real sample analysis was carried out with textile wastewater samples to check the applicability/accuracy of the developed method, using a matrix matching calibration strategy to enhance quantification accuracy. Satisfactory percent recoveries in the range of 93.3%-114.3% and 92%-92.7% were recorded for the SFODME-SDIC and SFODME-UV methods, respectively.
- 18 August 2023
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 195 (9) , 1-12
Quantification of trace fenuron in waste water samples by matrix matching calibration strategy and gas chromatography–mass spectrometry after simultaneous derivatization and preconcentration
This study presents a highly sensitive and accurate analytical strategy for the determination of fenuron in wastewater samples using gas chromatography–mass spectrometry (GC-MS). Simultaneous derivatization and spray-based fine droplet formation–liquid phase microextraction (SFDF-LPME) method was developed and performed to achieve low detection limits. The parameters of the derivatization and SFDF-LPME method were optimized by univariate approach to improve sensitivity and selectivity. Under the optimum SFDF-LPME-GC-MS conditions, the limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.15 and 0.49 mg/kg, respectively. In addition, the linear range was calculated as 0.51–24.50 mg/kg. Recovery studies were carried out on wastewater samples to determine the accuracy of the developed method and its applicability to real sample matrix. Matrix matching calibration strategy was applied to eliminate/reduce any possible interference effects caused by the complexity of the wastewater matrix and to increase the accuracy of the analytical results. Percent recovery results varied between 85.9 and 120.9% with small percent relative standard deviation values. These results were satisfactory in terms of the accuracy and applicability of the proposed method for wastewater samples.
- 18 August 2023
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 195 (9) , 1-12
Quantification of trace fenuron in waste water samples by matrix matching calibration strategy and gas chromatography–mass spectrometry after simultaneous derivatization and preconcentration
This study presents a highly sensitive and accurate analytical strategy for the determination of fenuron in wastewater samples using gas chromatography–mass spectrometry (GC-MS). Simultaneous derivatization and spray-based fine droplet formation–liquid phase microextraction (SFDF-LPME) method was developed and performed to achieve low detection limits. The parameters of the derivatization and SFDF-LPME method were optimized by univariate approach to improve sensitivity and selectivity. Under the optimum SFDF-LPME-GC-MS conditions, the limit of detection (LOD) and limit of quantitation (LOQ) were found to be 0.15 and 0.49 mg/kg, respectively. In addition, the linear range was calculated as 0.51–24.50 mg/kg. Recovery studies were carried out on wastewater samples to determine the accuracy of the developed method and its applicability to real sample matrix. Matrix matching calibration strategy was applied to eliminate/reduce any possible interference effects caused by the complexity of the wastewater matrix and to increase the accuracy of the analytical results. Percent recovery results varied between 85.9 and 120.9% with small percent relative standard deviation values. These results were satisfactory in terms of the accuracy and applicability of the proposed method for wastewater samples.
- 8 December 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (1) , 56-62
Determination of cobalt in chamomile tea samples at trace levels by flame atomic absorption spectrophotometry after poly(vinyl alcohol)-magnetic hydrogel based dispersive solid phase extraction
In this study, an analytical strategy was proposed for the determination of cobalt at trace levels by using a flame atomic absorption spectrophotometry (FAAS) system after magnetic hydrogel based dispersive solid phase extraction (MH-DSPE). Poly(vinyl alcohol) based magnetic hydrogels (PVA-MH) were synthesized easily, quickly, and cost effectively in the laboratory and used as an adsorbent material in the microextraction process. Under the optimum experimental conditions, the limit of detection (LOD) and limit of quantitation (LOQ) values were recorded as 4.2 and 14.1 μg L−1, respectively. To investigate the matrix effects on the analyte signal, spike experiments were performed using chamomile tea extracts and good recovery results were obtained between 85.7 and 113.8%. A 57.8-fold improvement was achieved in the detection power compared to that of a conventional FAAS system. The results obtained throughout all experimental studies demonstrated the applicability in addition to the accuracy of the method for the quantification of trace levels of cobalt with high accuracy in a chamomile tea matrix.
- 8 December 2022
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (1) , 56-62
Determination of cobalt in chamomile tea samples at trace levels by flame atomic absorption spectrophotometry after poly(vinyl alcohol)-magnetic hydrogel based dispersive solid phase extraction
In this study, an analytical strategy was proposed for the determination of cobalt at trace levels by using a flame atomic absorption spectrophotometry (FAAS) system after magnetic hydrogel based dispersive solid phase extraction (MH-DSPE). Poly(vinyl alcohol) based magnetic hydrogels (PVA-MH) were synthesized easily, quickly, and cost effectively in the laboratory and used as an adsorbent material in the microextraction process. Under the optimum experimental conditions, the limit of detection (LOD) and limit of quantitation (LOQ) values were recorded as 4.2 and 14.1 μg L−1, respectively. To investigate the matrix effects on the analyte signal, spike experiments were performed using chamomile tea extracts and good recovery results were obtained between 85.7 and 113.8%. A 57.8-fold improvement was achieved in the detection power compared to that of a conventional FAAS system. The results obtained throughout all experimental studies demonstrated the applicability in addition to the accuracy of the method for the quantification of trace levels of cobalt with high accuracy in a chamomile tea matrix.
- 4 August 2022
- Published by Elsevier in Journal of Pharmacological and Toxicological Methods
- Vol. 119, 107207
Combination of quadrupole isotope dilution mass spectrometry with simultaneous derivatization and spray assisted droplet formation-liquid phase microextraction for the determination of methamphetamine in human urine and serum samples by gas chromatography mass spectrometry
- 4 August 2022
- Published by Elsevier in Journal of Pharmacological and Toxicological Methods
- Vol. 119, 107207
Combination of quadrupole isotope dilution mass spectrometry with simultaneous derivatization and spray assisted droplet formation-liquid phase microextraction for the determination of methamphetamine in human urine and serum samples by gas chromatography mass spectrometry
- 6 September 2019
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 191 (10) , 619
Experimental design of switchable solvent–based liquid phase microextraction for the accurate determination of etrimfos from water and food samples at trace levels by GC-MS
Presented in this study is a simple but efficient switchable polarity solvent microextraction strategy for etrimfos preconcentration from water and food samples for quantification by gas chromatography mass spectrometry. Repeatability of the extraction process and instrumental measurements were enhanced by using deuterated bisphenol A as internal standard. Significant parameters of the extraction method were fitted into an experimental design model to study the effects of parameters on extraction output, as well as mutual effects of combined parameters. The design model was formed with 51 experimented data obtained from the combination of sodium hydroxide volume, switchable solvent volume, and vortex period at three levels. The method was validated by applying optimum conditions attained from the model predictor. The detection limit was found to be 1.3 ng/mL and it corresponded to an enhancement factor of about 54 folds when compared to direct GC-MS measurement. Etrimfos was not detected in the water and food samples tested but the results (92–107%) obtained from spiked recovery experiments established that etrimfos when present in the selected matrices can be accurately and precisely quantified.
- 6 September 2019
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 191 (10) , 619
Experimental design of switchable solvent–based liquid phase microextraction for the accurate determination of etrimfos from water and food samples at trace levels by GC-MS
Presented in this study is a simple but efficient switchable polarity solvent microextraction strategy for etrimfos preconcentration from water and food samples for quantification by gas chromatography mass spectrometry. Repeatability of the extraction process and instrumental measurements were enhanced by using deuterated bisphenol A as internal standard. Significant parameters of the extraction method were fitted into an experimental design model to study the effects of parameters on extraction output, as well as mutual effects of combined parameters. The design model was formed with 51 experimented data obtained from the combination of sodium hydroxide volume, switchable solvent volume, and vortex period at three levels. The method was validated by applying optimum conditions attained from the model predictor. The detection limit was found to be 1.3 ng/mL and it corresponded to an enhancement factor of about 54 folds when compared to direct GC-MS measurement. Etrimfos was not detected in the water and food samples tested but the results (92–107%) obtained from spiked recovery experiments established that etrimfos when present in the selected matrices can be accurately and precisely quantified.
- 30 September 2017
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 189 (10) , 528
A novel liquid-liquid extraction for the determination of naphthalene by GC-MS with deuterated anthracene as internal standard
- 30 September 2017
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 189 (10) , 528
A novel liquid-liquid extraction for the determination of naphthalene by GC-MS with deuterated anthracene as internal standard
- 28 May 2017
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 97 (7) , 684-693
Arsenic speciation in water and biota samples at trace levels by ion chromatography inductively coupled plasma-mass spectrometry
A sensitive, reliable, simple and rapid analytical method was developed for the determination of arsenite [As(III)], arsenate [As(V)] and arsenobetaine (AsB) species using ion chromatography combined with inductively coupled plasma-mass spectrometry (IC-ICP-MS). Inorganic and organic arsenic species were separated with an anion exchange column (Dionex AS9) and a 50 mM sodium bicarbonate mobile phase (pH 10) at a flow rate of 1.0 mL min−1. %RSD values were found to be lower than 5.1% for all arsenic species. The limits of detection (LOD) obtained for As(III), As(V) and AsB were 16.5 ng L−1, 14.1 ng L−1 and 6.2 ng L−1, respectively. The developed analytical method was tested using AsB certified reference material (NMIJ CRM 7901-a), and spring water certified reference material (UME CRM 1201) for accuracy check. This method was applied for the quantitative determination of arsenic species in different water samples and chicken samples as a solid matrix.
- 28 May 2017
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 97 (7) , 684-693
Arsenic speciation in water and biota samples at trace levels by ion chromatography inductively coupled plasma-mass spectrometry
A sensitive, reliable, simple and rapid analytical method was developed for the determination of arsenite [As(III)], arsenate [As(V)] and arsenobetaine (AsB) species using ion chromatography combined with inductively coupled plasma-mass spectrometry (IC-ICP-MS). Inorganic and organic arsenic species were separated with an anion exchange column (Dionex AS9) and a 50 mM sodium bicarbonate mobile phase (pH 10) at a flow rate of 1.0 mL min−1. %RSD values were found to be lower than 5.1% for all arsenic species. The limits of detection (LOD) obtained for As(III), As(V) and AsB were 16.5 ng L−1, 14.1 ng L−1 and 6.2 ng L−1, respectively. The developed analytical method was tested using AsB certified reference material (NMIJ CRM 7901-a), and spring water certified reference material (UME CRM 1201) for accuracy check. This method was applied for the quantitative determination of arsenic species in different water samples and chicken samples as a solid matrix.