Effect of Electrode Thickness on Quality Factor of Ring Electrode QCM Sensor
Open Access
Abstract
As a key type of sensor, the quartz crystal microbalance (QCM) has been widely used in many research areas. Recently, the ring electrode QCM sensor (R-QCM) with more uniform mass sensitivity has been reported. However, the quality factor (Q-factor) of the R-QCM has still not been studied, especially regarding the effect of electrode thickness on the Q-factor. Considering that the Q-factor is one of crucial parameter to the QCM and it is closely related to the output frequency stability of the QCM, we study the effect of different electrode thicknesses on the Q-factor of the R-QCM in this paper. On the other hand, we clarify the relationship between the electrode thickness and the Q-factor of the R-QCM. The measurement results show that the average Q-factor increases with increases in the thickness of ring electrodes generally; however, the resonance frequency of the QCM resonator decreases with increases in the thickness. The low half-bandwidth (2Γ < 1630 Hz) of the R-QCM shows that the frequency performance is good. Additionally, the R-QCM has a higher Q-factor (Q > 6000), which indicates that it has a higher frequency stability and can be applied in many research areas.Keywords
Funding Information
- China Scholarship Council (CSC 201806070063)
This publication has 23 references indexed in Scilit:
- Facile fabrication of high-performance QCM humidity sensor based on layer-by-layer self-assembled polyaniline/graphene oxide nanocomposite filmSensors and Actuators B: Chemical, 2018
- In situ real-time gravimetric and viscoelastic probing of surface films formation on lithium batteries electrodesNature Communications, 2017
- Enhanced Quality Factor Label-free Biosensing with Micro-Cantilevers Integrated into Microfluidic SystemsAnalytical Chemistry, 2017
- Quantification of the Mass and Viscoelasticity of Interfacial Films on Tin Anodes Using EQCM-DACS Applied Materials & Interfaces, 2015
- In Situ EQCM Study Examining Irreversible Changes the Sulfur–Carbon Cathode in Lithium–Sulfur BatteriesACS Applied Materials & Interfaces, 2015
- An electrodeless quartz crystal resonator integrated with UV/Vis spectroscopy for the investigation of the photodecomposition of methylene blueSensors and Actuators B: Chemical, 2014
- The EQCM: electrogravimetry with a light touchJournal of Solid State Electrochemistry, 2011
- Quartz Crystal Microbalance Studies of Polymer Gels and Solutions in Liquid EnvironmentsAnalytical Chemistry, 2006
- Analysis of the Radial Dependence of Mass Sensitivity for Modified-Electrode Quartz Crystal ResonatorsAnalytical Chemistry, 1998
- Verwendung von Schwingquarzen zur W gung d nner Schichten und zur Mikrow gungThe European Physical Journal A, 1959