Fine Needle Biopsies of Solid Pancreatic Lesions: Tissue Acquisition Technique and Needle Design Do Not Impact Specimen Adequacy
- 2 December 2021
- journal article
- research article
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 67 (9) , 4549-4556
Abstract
Background and Aims Data on adequacy of EUS guided biopsies using different tissue acquisition techniques and fine needle aspiration needle designs have been inconclusive. Data on newer fine needle biopsy (FNB) needles are scarce. This study compared the performance of 3 acquisition techniques and 2 fine needle biopsy designs in solid pancreatic lesions. Methods Single-center, randomized, pilot clinical trial (Trial registration number NCT03264092). Patients undergoing EUS biopsy of pancreatic lesions were randomized to 1 of 3 acquisition techniques (dry suction, wet suction, slow pull) and 1 of 2 22G FNB needle designs. The primary outcome was specimen cellularity. Secondary outcomes included blood contamination and number of passes needed for diagnosis. Results A total of 52 (35.3%), 49 (33.3%) and 46 (31.3%) specimens were obtained with slow pull, dry suction and wet suction, respectively. A total of 56 (38%) and 91 (62%) specimens were obtained with each needle, respectively. No difference in cellularity scores was identified by technique (3.28 vs 3.55 vs 2.94; p = 0.081) or needle type (3.45 vs 3.15; p = 0.19). The same was true for blood contamination and diagnostic pass. A diagnosis was reached after 3 passes in 51 patients (93%). Histological diagnosis was possible in 45 specimens (82%). No severe adverse events occurred. Conclusions Cellularity of pancreatic specimens obtained with FNB needles via EUS was not influenced by technique and needle design. Three passes were enough to obtain a histological diagnosis in most patients. Larger clinical trials are required to validate the results of this study.Keywords
This publication has 20 references indexed in Scilit:
- EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control studyGastrointestinal Endoscopy, 2016
- Slow-pull and different conventional suction techniques in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid lesions using 22-gauge needlesWorld Journal of Gastroenterology, 2016
- Effect of a stylet on a histological specimen in EUS-guided fine-needle tissue acquisition by using 22-gauge needles: a multicenter, prospective, randomized, controlled trialGastrointestinal Endoscopy, 2015
- “Wet suction technique (WEST)”: a novel way to enhance the quality of EUS-FNA aspirate. Results of a prospective, single-blind, randomized, controlled trial using a 22-gauge needle for EUS-FNA of solid lesionsGastrointestinal Endoscopy, 2015
- Slow Pull Versus Suction in Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Solid MassesDigestive Diseases and Sciences, 2014
- Diagnostic yield of malignancy during EUS-guided FNA of solid lesions with and without a stylet: a prospective, single blind, randomized, controlled trialGastrointestinal Endoscopy, 2012
- Endoscopic Ultrasound Guided Fine-needle Aspiration of Lymph Nodes and Solid MassesJournal of Clinical Gastroenterology, 2012
- EUS-guided FNA for diagnosis of solid pancreatic neoplasms: a meta-analysisGastrointestinal Endoscopy, 2012
- Randomized study comparing endoscopic ultrasound‐guided Trucut biopsy and fine needle aspiration with high suctionCytopathology, 2010
- Randomized controlled trial of endoscopic ultrasound-guided fine-needle sampling with or without suction for better cytological diagnosisScandinavian Journal of Gastroenterology, 2009