Performance of gas chromatography/tandem mass spectrometry in the analysis of pyrethroid insecticides in environmental and food samples
- 14 March 2011
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 25 (7) , 869-876
Abstract
The performance of gas chromatography coupled with tandem mass spectrometry (GC/MS/MS) was tested for the simultaneous determination of twelve pyrethroid insecticides. First, a comparison of two different ionization modes, electron ionization (EI) and negative chemical ionization (NCI), was carried out using MS and MS/MS. NCI‐MS/MS provided the best results in terms of selectivity and sensitivity giving very low detection limits of 0.11 to 450 fg injected. The reliability of the method was confirmed through the evaluation of quality parameters such as accuracy (70–100%), and repeatability and reproducibility, with coefficients of variation below 15% and 10%, respectively. The applicability of the GC/MS/MS method to real samples and influence of matrix effects were evaluated through the analysis of spiked water, sediment and milk at 0.25 ng L −1 , 5 ng g −1 dry weight (dw) and 25 ng g −1 (dw), respectively, of each pyrethroid insecticide considered. Using GC/NCI‐MS/MS, matrix spectral interferences were minimized providing method limits of detection (MLODs) of 0.05–2.59 ng L −1 , 0.10–87.7 pg g −1 dw, 2.29–1071 pg g −1 lipid weight (lw) for water, sediment and milk, respectively. To the best of our knowledge, the MLOD values found in our study were better than those reported in previous studies; in particular for sediment and food samples, they were one order of magnitude lower. Copyright © 2011 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Presence of pyrethroid pesticides in water and sediments of Ebro River DeltaJournal of Hydrology, 2010
- Determination of pyrethroid insecticides in environmental samplesTrAC Trends in Analytical Chemistry, 2010
- Determination of pyrethroid insecticides in sediment by gas chromatography—Ion trap tandem mass spectrometryTalanta, 2010
- Assessing the Occurrence and Distribution of Pyrethroids in Water and Suspended SedimentsJournal of Agricultural and Food Chemistry, 2009
- Analysis of pyrethroids in sediment pore water by solid-phase microextractionEnvironmental Toxicology and Chemistry, 2007
- Screening method for pesticides in air by gas chromatography/tandem mass spectrometryRapid Communications in Mass Spectrometry, 2004
- Optimization of High Quality Analytical Methods for the Monitoring of Pyrethroid Mothproofing Agents by Gas Chromatography-Mass Spectrometry Operated in Negative-Ion Chemical Ionization ModeInternational Journal of Environmental Analytical Chemistry, 1997
- Synthetic pyrethroid insecticides in fish: Analysis by gas chromatography‐mass spectrometry operated in the negative ion chemical ionization mode and ELISAFood and Agricultural Immunology, 1996
- Determination of pyrethroid insecticides by ion trap GC-MS-MSAnalytica Chimica Acta, 1995
- Determination of permethrin and cyfluthrin in water and sediment by gas chromatography-mass spectrometry operated in the negative chemical ionization modeJournal of Chromatography A, 1995