Embolic Cerebrovascular Accident Secondary to Device-Related Thrombus Post WATCHMAN Device Implantation
Open Access
- 15 July 2022
- journal article
- research article
- Published by Springer Nature in Cureus
- Vol. 14 (7) , e26892
Abstract
Atrial fibrillation (AF) is one of the most common cardiac arrhythmias encountered. Aggressive and appropriate management, along with identification and modification of risk factors, remains at the forefront of evidence-based practice. Thrombus formation (primarily in the left atrial appendage) and consequent thromboembolism are risks associated with AF. Anticoagulation is utilized to prevent and reduce AF-induced complications such as stroke, heart failure, and death. However, in instances when the risk of bleeding from anticoagulation outweighs the benefits of stroke prevention, other modalities such as left atrial appendage closure (LAAC) devices like the WATCHMAN device (Boston Scientific, MA) are utilized. LAAC devices, such as the WATCHMAN device, are also not without significant risks, one of them being device-related thrombus (DRT) formation. We present a case of device-related thrombus formation post WATCHMAN implantation and a subsequent embolic cerebrovascular accident (CVA).Keywords
This publication has 15 references indexed in Scilit:
- A comparison of postprocedural anticoagulation in high‐risk patients undergoing WATCHMAN device implantationPacing and Clinical Electrophysiology, 2019
- Left Atrial Appendage ClosureCirculation, 2018
- Device-Related Thrombus After Left Atrial Appendage ClosureCirculation, 2018
- Device-Related Thrombosis After Percutaneous Left Atrial Appendage Occlusion for Atrial FibrillationJACC, 2018
- Impact of atrial fibrillation on inpatient cost for ischemic stroke in the USAInternational Journal of Stroke, 2018
- The Efficacy and Safety of the WATCHMAN Device in LAA Occlusion in Patients with Non-Valvular Atrial Fibrillation Contraindicated to Oral Anticoagulation: A Focused ReviewAnnals of Thoracic and Cardiovascular Surgery, 2018
- Oral Anticoagulation, Aspirin, or No Therapy in Patients With Nonvalvular AF With 0 or 1 Stroke Risk Factor Based on the CHA2DS2-VASc ScoreJACC, 2015
- Prospective Randomized Evaluation of the Watchman Left Atrial Appendage Closure Device in Patients With Atrial Fibrillation Versus Long-Term Warfarin TherapyJACC, 2014
- 2012 focused update of the ESC Guidelines for the management of atrial fibrillationEuropean Heart Journal, 2012
- Intraprocedural and Long‐Term Incomplete Occlusion of the Left Atrial Appendage Following Placement of the WATCHMAN Device: A Single Center ExperienceJournal of Cardiovascular Electrophysiology, 2011